40 C.F.R. Table 4 to Subpart HHHHH of Part 63

Emission Limits and Work Practice Standards for Wastewater Streams

Last amended: 2016Year: 2026Length: 131 wordsOfficial source

Cite as 40 C.F.R. Table 4 to Subpart HHHHH of Part 63 (2026)

As required in § 63.8020, you must meet each emission limit and work practice standard in the following table that applies to your wastewater streams. For each . . . You must . . . 1. Wastewater tank used to store a Group 1 wastewater stream Maintain a fixed roof, which may have openings necessary for proper venting of the tank, such as pressure/vacuum vent or j-pipe vent. 2. Group 1 wastewater stream a. Convey using hard-piping and treat the wastewater as a hazardous waste in accordance with 40 CFR part 264, 265, or 266 either onsite or offsite; or b. If the wastewater contains <50 ppmw of partially soluble HAP, you may elect to treat the wastewater in an enhanced biological treatment system that is located either onsite or offsite.
Cross-references to the CFR
63.8020
40 C.F.R. Table 4 to Subpart HHHHH of Part 63: Emission Limits and Work Practice Standards for Wastewater Streams | Justis AI