40 C.F.R. Table 5 to Subpart HHHHH of Part 63

Emission Limits and Work Practice Standards for Transfer Operations

Last amended: 2016Year: 2026Length: 213 wordsOfficial source

Cite as 40 C.F.R. Table 5 to Subpart HHHHH of Part 63 (2026)

As required in § 63.8025, you must meet each emission limit and work practice standard in the following table that applies to your transfer operations. For each . . . You must. . . . 1. Group 1 transfer operation vent stream a. Reduce emissions of total organic HAP by ≥75 percent by weight by venting emissions through a closed-vent system to any combination of control devices (except a flare); or b. Reduce emissions of total organic HAP by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare; or c. Use a vapor balancing system designed and operated to collect organic HAP vapors displaced from tank trucks and railcars during loading and route the collected HAP vapors to the storage tank from which the liquid being loaded originated or to another storage tank connected by a common header. 2. Halogenated Group 1 transfer operation vent stream for which you use a combustion device to control organic HAP emissions a. Use a halogen reduction device after the combustion device to reduce emissions of hydrogen halide and halogen HAP by ≥95 percent by weight or to ≤0.45 kg/hr; or b. Use a halogen reduction device before the combustion device to reduce the halogen atom mass emission rate to ≤0.45 kg/hr.
Cross-references to the CFR
63.8025
40 C.F.R. Table 5 to Subpart HHHHH of Part 63: Emission Limits and Work Practice Standards for Transfer Operations | Justis AI