HAR §11-45-185
HAR §11-45-185. Operating procedures
Cite as Haw. Code R. § 11-45-185
(a) Particle
accelerators, when not in operation, shall be secured to prevent
unauthorized use.
(b)
The safety interlock system shall not be used to turn
off the accelerator beam except in an emergency.
(c)
All safety and warning devices, including interlocks,
shall be checked for proper operation at intervals not to exceed
three months. Results of such tests shall be maintained at the
accelerator facility for inspection by the department for three
years.
(d)
Electrical circuit diagrams of the accelerator and the
associated safety interlock systems shall be kept current and
maintained for inspection by the department and shall be available
to the operator at each accelerator facility.
(e)
If, for any reason, it is necessary to intentionally
bypass a safety interlock or interlocks, such action shall be:
(1)
Authorized by the radiation safety committee or
radiation safety officer;
(2)
Recorded in a permanent log and a notice posted at the
accelerator control console; and
(3)
Terminated as soon as possible.
(f)
A copy of the current operating and the emergency
procedures shall be maintained at the accelerator control panel.
§11-45-187
45-147
[Eff 11/12/99] (Auth: HRS §§321-10, 321-11, 321-71) (Imp: HRS
§§321-1, 321-11(21), 321-71)