HAR §11-45-186
HAR §11-45-186. Radiation monitoring requirements
Cite as Haw. Code R. § 11-45-186
(a) There
shall be available at each particle accelerator facility
appropriate portable monitoring equipment which is operable and
has been appropriately calibrated for the radiation being produced
at the facility. Such equipment shall be tested for proper
operation daily and calibrated at intervals not to exceed one year
and after each servicing and repair.
(b)
A radiation protection survey shall be performed and
documented by a qualified health or medical physicist when changes
have been made in shielding, operation, equipment, or occupancy of
adjacent areas.
(c)
Radiation levels in all high radiation areas shall be
continuously monitored. The monitoring devices shall be
electrically independent of the accelerator control and safety
interlock systems and capable of providing a readout at the
control panel.
(d)
All area monitors shall be calibrated at intervals not
to exceed one year and after each servicing and repair.
(e)
Whenever applicable, periodic surveys shall be made to
determine the amount of airborne particulate radioactivity
present.
(f)
Whenever applicable, periodic smear surveys shall be
made to determine the degree of contamination.
(g)
All surveys shall be made in accordance with the
written procedures established by a qualified health or medical
physicist or the radiation safety officer.
(h)
Records of all radiation protection surveys,
calibrations, and instrumentation tests shall be maintained at the
accelerator facility for inspection by the department for three
years. [Eff 11/12/99] (Auth: HRS §§321-10, 321-11, 321-71)