HAR §11-45-56
HAR §11-45-56. Control of access to very high radiation areas
Cite as Haw. Code R. § 11-45-56
(a) In addition to the requirements in section 11-45-55, the
licensee shall institute additional measures to ensure that an
individual is not able to gain unauthorized or inadvertent access
to areas in which radiation levels could be encountered at five
hundred rads (five grays) or more in one hour at one meter from a
source of radiation or any surface through which the radiation
penetrates. This requirement does not apply to rooms or areas in
which diagnostic x-ray systems are the only source of radiation,
or to non-self-shielded irradiators.
(b)
The licensee is not required to control entrance or
access to rooms or other areas containing sources of radiation
capable of producing a very high radiation area as described in
subsection (a) if the licensee has met all the specific
requirements for access and control specified in other applicable
subchapters. [Eff 11/12/99] (Auth: HRS §§321-10, 321-11, 321-
71) (Imp: HRS §§321-1, 321-11(21), 321-71)
§11-45-57 Control of access to very high radiation areas --
irradiators. (a) This section applies to licensees with sources
of radiation in non-self-shielded irradiators, and does not apply
to sources of radiation that are used in teletherapy, in
industrial radiography, or in completely self-shielded irradiators
in which the source of radiation is both stored and operated
within the same shielding radiation barrier and, in the designed
configuration of the irradiator, is always physically inaccessible
to any individual and cannot create a radiation level of five
hundred rads (five grays) or more in one hour at one meter in an
area that is accessible to any individual.
(b)
Each area in which there may exist radiation levels in
excess of five hundred rads (five grays) in one hour at one meter
from a source of radiation that is used to irradiate materials
shall meet the following requirements:
(1)
Each entrance or access point shall be equipped with
entry control devices which:
(A)
Function automatically to prevent any individual
§11-45-57
45-63
from inadvertently entering a very high
radiation area; and
(B)
Permit deliberate entry into the area only after
a control device is actuated that causes the
radiation level within the area, from the source
of radiation, to be reduced below that at which
it would be possible for an individual to
receive a deep dose equivalent in excess of 0.1
rem (one millisievert) in one hour; and
(C)
Prevent operation of the source of radiation if
it would produce radiation levels in the area
that could result in a deep dose equivalent to
an individual in excess of 0.1 rem (one
millisievert) in one hour.
(2)
Additional control devices shall be provided so that,
upon failure of the entry control devices to function
as required by paragraph (1):
(A)
The radiation level within the area, from the
source of radiation, is reduced below that at
which it would be possible for an individual to
receive a deep dose equivalent in excess of 0.1
rem (one millisievert) in one hour; and
(B)
Conspicuous visible and audible alarm signals
are generated to make an individual attempting
to enter the area aware of the hazard and at
least one other authorized individual, who is
physically present, familiar with the activity,
and prepared to render or summon assistance,
aware of the failure of the entry control
devices.
(3)
The licensee shall provide control devices so that,
upon failure or removal of physical radiation barriers
other than the source's shielded storage container:
(A)
The radiation level from the source of radiation
is reduced below that at which it would be
possible for an individual to receive a deep
dose equivalent in excess of 0.1 rem (one
millisievert) in one hour; and
(B)
Conspicuous visible and audible alarm signals
are generated to make potentially affected
individuals aware of the hazard and the licensee
or at least one other individual, who is
familiar with the activity and prepared to
render or summon assistance, aware of the
failure or removal of the physical barrier.
(4)
When the shield for stored sealed sources is a liquid,
the licensee shall provide means to monitor the
integrity of the shield and to signal, automatically,
loss of adequate shielding.
(5)
Physical radiation barriers that comprise permanent
structural components, such as walls, that have no
credible probability of failure or removal in ordinary
circumstances need not meet the requirements of
paragraphs (3) and (4).
§11-45-57
45-64
(6)
Each area shall be equipped with devices that shall
automatically generate conspicuous visible and audible
alarm signals to alert personnel in the area before
the source of radiation can be put into operation and
in time for any individual in the area to operate a
clearly identified control device, which shall be
installed in the area and which can prevent the source
of radiation from being put into operation.
(7)
Each area shall be controlled by use of such
administrative procedures and such devices as are
necessary to ensure that the area is cleared of
personnel before each use of the source of radiation.
(8)
Each area shall be checked by a radiation measurement
to ensure that, before the first individual's entry
into the area after any use of the source of
radiation, the radiation level from the source of
radiation in the area is below that at which it would
be possible for an individual to receive a deep dose
equivalent in excess of 0.1 rem (one millisievert) in
one hour.
(9)
The entry control devices required in paragraph (1)
shall have been tested for proper functioning.
(A)
Testing shall be conducted before initial
operation with the source of radiation on any
day, unless operations were continued
uninterrupted from the previous day; and
(B)
Testing shall be conducted before resumption of
operation of the source of radiation after any
unintentional interruption; and
(C)
The licensee shall submit and adhere to a
schedule for periodic tests of the entry control
and warning systems.
(10)
The licensee shall not conduct operations, other those
necessary to place the source of radiation in safe
condition or to effect repairs on controls, unless
control devices are functioning properly.
(11)
Entry and exit portals that are used in transporting
materials to and from the irradiation area, and that
are not intended for use by individuals, shall be
controlled by such devices and administrative
procedures as are necessary to physically protect and
warn against inadvertent entry by any individual
through these portals. Exit portals for irradiated
materials shall be equipped to detect and signal the
presence of any loose radioactive material that is
carried toward such an exit and automatically to
prevent loose radioactive material from being carried
out of the area.
(c)
Licensees of sources of radiation within the purview
of subsection (b) which shall be used in a variety of positions or
in locations, such as open fields or forests, that make it
impracticable to comply with certain requirements of subsection
(b), such as those for the automatic control of radiation levels,
may apply to the department for approval of alternative safety
§11-45-60
45-65
measures. Alternative safety measures shall provide personnel
protection at least equivalent to those specified in subsection
(b). At least one of the alternative measures shall include an
entry-preventing interlock control based on a measurement of the
radiation that ensures the absence of high radiation levels before
an individual can gain access to the area where such sources of
radiation are used.
(d)
The entry control devices required by subsections (b)
and (c) shall be established in such a way that no individual
shall be prevented from leaving the area. [Eff 11/12/99] (Auth:
HRS §§321-10, 321-11, 321-71) (Imp: HRS §§321-1, 321-11(21),
321-71)