HAR §11-502-8
HAR §11-502-8. Assessment
Length: 417 wordsOfficial source
Cite as Haw. Code R. § 11-502-8
(a) For each inspection
and reinspection conducted pursuant to section 11-502-
5(a) and (c) and previous inspections specified
pursuant to section 11-502-15, the local education
agency shall have a certified inspector provide a
written assessment of all friable known or assumed ACBM
in the school building. Each certified inspector
providing a written assessment shall sign and date the
assessment, provide the inspector's state of
certification and certification number, and submit a
copy of the assessment to the person designated
pursuant to section 11-502-4 for inclusion in the
management plan within thirty days of the assessment.
(b)
The inspector shall classify and give reasons
in the written assessment for classifying the ACBM and
suspected ACBM assumed to be ACM in the school building
into one of the following categories.
(1)
Damaged or significantly damaged thermal
system insulation ACM;
(2)
Damaged friable surfacing ACM;
(3)
Significantly damaged friable surfacing ACM;
(4)
Damaged or significantly damaged friable
miscellaneous ACM;
(5)
ACBM with potential for damage;
(6)
ACBM with potential for significant damage;
and
(7)
Any remaining friable ACBM or friable
suspected ACBM.
(c)
Assessment shall include the following
considerations:
(1)
Location and the amount of the material, both
in total quantity and as a percentage of the
functional space;
(2)
Condition of the material, specifying:
(A)
Type of damage or significant damage
(e.g., flaking, blistering, water
damage, or other signs of physical
damage);
(B)
Severity of damage (e.g., major flaking,
severely torn jackets, as opposed to
occasional flaking, minor tears to
jackets); and
(C)
Extent or spread of damage over large
areas or large percentages of the
homogeneous area;
(3)
Whether the material is accessible;
(4)
The material's potential for disturbance;
(5)
Known or suspected causes of damage or
significant damage (e.g., air erosion,
vandalism, vibration, water); and
(6)
Preventive measures which might eliminate the
reasonable likelihood of undamaged ACM from
becoming significantly damaged.
(d)
The local education agency shall select a
person certified to develop management plans pursuant
to section 11-504-34 to review the results of each
inspection, reinspection, and assessment for the school
building and to conduct any other necessary activities
in order to recommend in writing to the local education
agency appropriate response actions. The certified
person shall sign and date the recommendation, provide
his or her state of certification, provide his or her
certification number, and submit a copy of the
recommendation to the person designated pursuant to
section 11-502-4 for inclusion in the management plan.
[Eff ] (Auth: HRS §321-11(26)) (Imp: 40