HAR §11-50-48. Location and installation
Cite as Haw. Code R. § 11-50-48
(a)
clothes washers and dryers, and storage cabinets,
contamination prevention.
Equipment,
(1)
Except as specified in paragraph (2), equipment,
a cabinet used for the storage of food, or a
cabinet that is used to store cleaned and
sanitized equipment, utensils, laundered linens,
and single-service and single-use articles may
not be located:
(A)
In locker rooms;
(B)
In toilet rooms;
(C)
In garbage rooms;
(D)
In mechanical rooms;
(E)
Under sewer lines that are not shielded to
intercept potential drips;
(F)
Under leaking water lines including leaking
automatic fire sprinkler heads or under
lines on which water has condens~d;
(G)
Under open stairwells; or
(H)
Under other sources of contamination;
(2)
A storage cabinet used for linens or single-
service or single-use articles may be stored in a
locker room;
50-127
§11-50-48
(3)
If a mechanical clothes washer or dryer is
provided, it shall be located so that the washer
or dryer is protected from contamination and only
where there is no exposed food; clean equipment,
utensils, and linens; and unwrapped single-
service and single-use articles.
(b)
Fixed equipment, spacing or sealing.
(1)
Equipment that is fixed because it is not easily
movable shall be installed so that it is:
(A)
Spaced to allow access for cleaning along
the sides, behind, and above the equipment;
(B)
Spaced from adjoining equipment, walls, and
ceilings a distance of not more than one
millimeter or one thirty-second inch; or
(C)
Sealed to adjoining equipment or walls, if
the equipment is exposed to spillage or
seepage;
(2)
Counter-mounted equipment that is not easily
movable shall be installed to allow cleaning of
the equipment and areas underneath and around the
equipment by being:
(A)
Sealed; or
(B)
Elevated on legs as specified in subsection
(c) ( 4).
(c)
Fixed equipment, elevation or sealing.
(1)
Except as specified in paragraphs (2) and (3),
floor-mounted equipment that is not easily
movable shall be sealed to the floor or elevated
on legs that provide at least a six inch
clearance between the floor and the equipment;
(2)
If no part of the floor under the floor-mounted
equipment is more than six inches from the point
of cleaning access, the clearance space may be
only four inches;
(3)
This section does not apply to display shelving
units, display refrigeration units, and display
freezer units located in the consumer shopping
areas of a retail food store, if the floor under
the units is maintained clean;
(4)
Except as specified in paragraph (5), counter-
mounted equipment that is not easily movable
shall be elevated on legs that provide at least a
four inch clearance between the table and the
equipment;
(5)
The clearance space between the table and
counter-mounted equipment may be:
50-128
§11-50-49
(A)
Three inches if the horizontal distance of
the table top under the equipment is no
more than twenty inches from the point of
access for cleaning; or
(B)
Two inches if the horizontal distance of
the table top under the equipment is no
more than three inches from the point of
access for cleaning.
[Eff 2/24/2014; am
and comp AUG 2 4 2025
] (Auth: HRS
§321-11)
(Imp: HRS §321-11)