HAR §11-50-61
HAR §11-50-61. Plumbing system
Cite as Haw. Code R. § 11-50-61
(a)
Approved.
(1)
A plumbing system and hoses conveying water shall
be constructed and repaired with approved
materials according to law;
(2)
A water filter shall be made of safe materials.
(b)
Approved system and cleanable fixtures.
(1)
A plumbing system shall be designed, constructed,
and installed according to law;
(2)
A plumbing fixture such as a handwashing sink,
toilet, or urinal shall be easily cleanable.
(c)
Handwashing sink, installation.
(1)
A handwashing sink, if provided with hot water,
shall be equipped with a mixing valve or
combination faucet;
(2)
A steam mixing valve may not be used at a
handwashing sink;
(3)
A self-closing, slow-closing, or metering faucet
shall provide a flow of water for at least
fifteen seconds without the need to reactivate
the faucet;
(4)
An automatic handwashing facility shall be
installed in accordance with manufacturer's
instructions;
(5)
Faucets shall provide a sufficient flow of water
to permit proper washing and rinsing of hands.
(d)
An air gap between the water supply inlet and the
flood level rim of the plumbing fixture, equipment, or
nonfood equipment shall be at least twice the diameter of
the water supply inlet and may not be less than one inch.
(e)
A backflow or backsiphonage prevention device
installed on a water supply system shall meet American
Society of Sanitary Engineering (A.S.S.E.) standards for
50-145
§11-50-61
construction, installation, maintenance, inspection, and
testing for that specific application and type of device.
(f)
A water filter, screen, and other water
conditioning device installed on water lines shall be
designed to facilitate disassembly for periodic servicing
and cleaning.
A water filter element shall be of the
replaceable type.
(g)
Handwashing sinks.
(1)
Except as specified in paragraph (2), at least
one handwashing sink, a number of handwashing
sinks necessary for their convenient use by
employees in areas specified in subsection (1),
and not fewer than the number of handwashing
sinks required by law shall be provided;
(2)
If approved and capable of removing the types of
soils encountered in the food operations
involved, automatic handwashing facilities may be
substituted for handwashing sinks in a food
establishment that has at least one handwashing
sink.
(h)
At least one toilet and not fewer than the
toilets required by law shall be provided.
(i)
Facilities for disposal of mop water and similar
liquid waste shall be provided.
At least one service sink
or one curbed cleaning facility equipped with a floor drain
shall be provided and conveniently located for the cleaning
of mops or similar wet floor cleaning tools and for the
disposal of mop water and similar liquid waste for newly
constructed or extensively remodeled establishments; except
that the director may waive this requirement if an
alternative liquid waste disposal facility is readily
available.
(j)
A plumbing system shall be installed to preclude
backflow of a solid, liquid, or gas contaminant into the
water supply system at each point of use at the food
establishment, including on a hose bibb if a hose is
attached or on a hose bibb if a hose is not attached and
backflow prevention is required by law, by:
(1)
Providing an air gap as specified in subsection
(d); or
(2)
Installing an approved backflow prevention device
as specified in subsection (e).
(k)
Backflow prevention device, carbonator.
(1)
If not provided with an air gap as specified in
subsection (d), a dual check valve with an
intermediate vent preceded by a screen of not
50-146
§11-50-61
less than one hundred mesh to one inch shall be
installed upstream from a carbonating device and
downstream from any copper in the water supply
line;
(2)
A dual check valve attached to the carbonator
need not be of the vented type if an air gap or
vented backflow prevention device has been
otherwise provided as specified in paragraph (1)
(1)
A handwashing sink shall be located:
(1)
To allow convenient use by employees in food
preparation, food dispensing, and warewashing
areas; and
(2)
In, or immediately adjacent to, toilet rooms.
(m)
A backflow prevention device shall be located so
that it may be serviced and maintained.
(n)
A water filter, screen, and other water
conditioning device installed on water lines shall be
located to facilitate disassembly for periodic servicing
and cleaning.
(o)
Using a handwashing sink.
(1)
A handwashing sink shall be maintained so that it
is accessible at all times for employee use;
(2)
A handwashing sink may not be used for purposes
other than handwashing;
(3)
An automatic handwashing facility shall be used
in accordance with manufacturer's instructions.
(p)
Prohibiting a cross connection.
(1)
A person may not create a cross connection by
connecting a pipe or conduit between the drinking
water system and a nondrinking water system or a
water system of unknown quality;
(2)
The piping of a nondrinking water system shall be
durably identified so that it is readily
distinguishable from piping that carries drinking
water.
(q)
Water reservoir of fogging devices, cleaning.
(1)
A reservoir that is used to supply water to a
device such as a produce fogger shall be:
(A)
Maintained in accordance with
manufacturer's specifications; and
(B)
Cleaned in accordance with manufacturer's
specifications or according to the
procedures specified in paragraph (2),
whichever is more stringent;
50-147
§11-50-61
(2)
Cleaning procedures shall include at least the
following steps and shall be conducted at least
once a week:
(A)
Draining and complete disassembly of the
water and aerosol contact parts;
(Bl
Brush-cleaning the reservoir, aerosol
tubing, and discharge nozzles with a
suitable detergent solution;
(C)
Flushing the complete system with water to
remove the detergent solution and
particulate accumulation; and
(D)
Rinsing by immersing, spraying, or swabbing
the reservoir, aerosol tubing, and
discharge nozzles with at least fifty mg/L
hypochlorite solution.
(r)
A plumbing system shall be:
(1)
Repaired according to law; and
(2)
Maintained in good repair.
(s)
Water tanks.
Materials that are used in the
construction of a water tank, and appurtenances
shall be:
(1)
Safe;
(2)
Durable, corrosion-resistant, and nonabsorbent;
and
(3)
Finished to have a smooth, easily cleanable
surface.
(t)
A water tank shall be:
(1)
Enclosed from the filling inlet to the discharge
outlet; and
(2)
Sloped to an outlet that allows complete drainage
of the tank.
(u)
If a water tank is designed with an access
port for inspection and cleaning, the opening shall be
in the top of the tank and:
(1)
Flanged upward at least one-half inch; and
(2)
Equipped with a port cover assembly that is:
(A)
Provided with a gasket and device for
securing the cover in place; and
(B)
Flanged to overlap the opening and sloped
to drain.
(v)
A fitting with "V" type threads on a water tank
inlet or outlet shall be allowed only when a hose
is permanently attached.
(w)
If provided, a water tank vent shall terminate in
a downward direction and shall be covered with:
50-148
§11-50-61
(1)
Sixteen mesh to one inch screen or equivalent
when the vent is in a protected area; or
(2)
A protective filter when the vent is in an area
that is not protected from windblown dirt and
debris.
(x)
Inlet and outlet, sloped to drain.
(1)
A water tank and its inlet and outlet
shall be sloped to drain;
(2)
A water tank inlet shall be positioned so that it
is protected from contaminants such as waste
discharge, road dust, oil, or grease;
(3)
A water tank inlet shall be three-fourths inch in
inner diameter or less; and
(4)
Provided with a hose connection of a size or type
that will prevent its use for any other service.
(y)
A hose used for conveying drinking water from a
water tank shall be:
(1)
Sa_fe;
(2)
Durable, corrosion-resistant, and nonabsorbent;
(3)
Resistant to pitting, chipping, crazing,
scratching, scoring, ~istortion, and
decomposition;
(4)
Finished with a smooth interior surface; and
(5)
Clearly and durably identified as to its use if
not permanently attached.
(z)
A filter that does not pass oil or oil vapors
shall be installed in the air supply line between the
compressor and drinking water system when compressed air is
used to pressurize the water tank system.
(aa)
A cap and keeper chain, closed cabinet, closed
storage tube, or other approved protective cover or device
shall be provided for a water inlet, outlet, and hose.
(bb)
A water tank, pump, and hoses shall be flushed
and sanitized before being placed in service after
construction, repair, modification, and periods of nonuse.
(cc)
A person shall operate a water tank, pump, and
hoses so that backflow and other contamination of the water
supply are prevented.
(dd)
If not in use, a water tank and hose inlet and
outlet fitting shall be protected using a cover or device
as specified in subsection (aa).
(ee)
Tank, pump, and hoses, dedication.
(1)
Except as specified in paragraph (2), a water
tank, pump, and hoses used for conveying drinking
water shall be used for no other purpose;
50-149
§11-50-61
(2)
Water tanks, pumps, and hoses approved for liquid
foods may be used for conveying drinking water if
they are cleaned and sanitized before they are used to
convey2
w4a~.
[Eff 2/24/2014; am and comp
AUG
ZUL:J
] (Auth: HRS §321-11)
(Imp:
HRS §321-11)