HAR §11-50-71. Design, construction, and installation
Length: 1,280 wordsOfficial source
Cite as Haw. Code R. § 11-50-71
(a)
Except as specified in subsection (d) and except for
antislip floor coverings or applications that may be used
for safety reasons, floors, floor coverings, walls, wall
coverings, and ceilings shall be designed, constructed, and
installed so they are smooth and easily cleanable.
(b)
Floors, walls, and ceilings, utility lines.
(1)
Utility service lines and pipes may not be
unnecessarily exposed;
(2)
Exposed utility service lines and pipes shall be
installed so they do not obstruct or prevent
cleaning of the floors, walls, or ceilings;
(3)
Exposed horizontal utility service lines and
pipes may not be installed on the floor.
(c)
Floor and wall junctures, coved, and enclosed or
sealed.
50-155
§11-50-71
(1)
(2)
(d)
(1)
(2)
(e)
removable
( f)
(1)
(2)
(g)
(1)
In food establishments in which cleaning methods
other than water flushing are used for cleaning
floors, the floor and wall junctures shall be
coved and closed to no larger than one thirty-
second inch;
The floors in food establishments in which water
flush cleaning methods are used shall be provided
with drains and be graded to drain, and the floor
and wall junctures shall be coved and sealed.
Floor carpeting, restrictions and installation.
A floor covering such as carpeting or similar
material may not be installed as a floor covering
in food preparation areas, walk-in refrigerators,
warewashing areas, toilet room areas where
handwashing lavatories, toilets, and urinals are
located, refuse storage rooms, or other areas
where the floor is subject to moisture, flushing,
or spray cleaning methods;
If carpeting is installed as a floor covering in
areas other than those specified in paragraph
(1), it shall be:
(A)
Securely attached to the floor with a
durable.mastic, by using a stretch and tack
method, or by another method; and
(B)
Installed tightly against the wall under
the coving or installed away from the wall
with a space between the carpet and the
wall and with the edges of the carpet
secured by metal stripping or some other
means.
Mats and duckboards shall be designed to be
and easily cleanable.
Wall and ceiling coverings and coatings.
Wall and ceiling covering materials shall be
attached so that they are easily cleanable;
Except in areas used only for dry storage,
concrete, porous blocks, or bricks uied for
indoor wall construction shall be finished and
sealed to provide a smooth, nonabsorbent, easily
cleanable surface.
Walls and ceilings, attachments.
Except as specified in paragraph (2), attachments
to walls and ceilings such as light fixtures,
mechanical room ventilation system components,
vent covers, wall mounted fans, decorative items,
and other attachments shall be easily cleanable;
50-156
§11-50-71
(2)
In a consumer area, wall and ceiling surfaces and
decorative items and attachments that are
provided for ambiance need not meet this
requirement if they are kept clean.
(h)
Light bulbs, protective shielding.
(1)
Except as specified in paragraph (2), light bulbs
shall be shielded, coated, or otherwise shatter-
resistant in areas where there is exposed food;
clean equipment, utensils, and linens; or
unwrapped single-service and single-use articles;
(2)
Shielded, coated, or otherwise shatter-resistant
bulbs need not be used in areas used only for
storing food in unopened packages, if:
(A)
The integrity of the packages cannot be
affected by broken glass falling onto them;
and
(B)
The packages are capable of being cleaned
of debris from broken bulbs before the
packages are opened;
(3)
An infrared or other heat lamp shall be protected
against breakage by a shield surrounding and
extending beyond the bulb so that only the face
of the bulb is exposed.
(i)
Heating, ventilating, and air conditioning
systems shall be designed and installed so that make-up air
intake and exhaust vents do not cause contamination of
food, food-contact surfaces, equipment, or utensils.
(j)
Insect control devices, design and installation.
(1)
Insect control devices that are used to
electrocute or stun flying insects shall be
designed to retain the insect within the device;
(2)
Insect control devices shall be installed so
that:
(A)
The devices are not located over a food
preparation area; and
(B)
Dead insects and insect fragments are
prevented from being impelled onto or
falling on exposed food; clean equipment,
utensils, and linens; and unwrapped single-
service and single-use articles.
(k)
Except where a toilet room is located outside a
food establishment and does not open directly into the food
establishment such as a toilet room that is provided by the
management of a shopping mall, a toilet room located on the
premises shall be completely enclosed and provided with a
tight-fitting and self-closing door.
50-157
§11-50-71
(1)
Outer openings, protected.
(1)
Except as specified in paragraphs (2) to (5),
outer openings of a food establishment shall be
protected against the entry of insects and
rodents by:
(A)
Filling or closing holes and other gaps
along floors, walls, and ceilings;
(B)
Closed, tight-fitting windows; and
(C)
Solid, self-closing, tight-fitting doors;
(2)
Paragraph (1) does not apply if a food
establishment opens into a larger structure, such
as a mall, airport, or office building, or into
an attached structure, such as a porch, and the
outer openings from the larger or attached
structure are protected against the entry of
insects and rodents;
(3)
Exterior doors used as exits need not be self-
closing if they are:
(A)
Solid and tight-fitting;
(B)
Designated for use only when an emergency
exists, by the fire protection authority
that has jurisdiction over the food
establishment; and
(C)
Limited-use so they are not used for
entrance or exit from the building for
purposes other than the designated
emergency exit use;
(4)
Except as specified in paragraphs (2) and (5), if
the windows or doors of a food establishment, or
of a larger structure within which a food
establishment is located, are kept open for
ventilation or other purposes, the openings shall
be protected against the entry of insects,
rodents and other pests by:
(A)
Sixteen mesh to one inch screens;
(B)
Properly designed and installed air
curtains to control flying insects; or
(C)
Other effective means;
(5)
Paragraph (4) does not apply if flying insects
and other pests are absent due to the location of
the establishment, the weather, or other limiting
condition;
(6)
The requirements of this section may be waived or
modified when alternative controls acceptable to
the director are utilized to ensure that all food
and food-contact surfaces of equipment and
50-158
§11-50-72
utensils are effectively protected against
contamination, and no other public health hazards
will result from the conduct of the operation.
(m)
Perimeter walls and roofs of a food establishment
shall effectively protect the establishment from the
weather and the entry of insects, rodents, and other
animals.
(n)
Except for machines that vend canned beverages,
if located outside, a machine used to vend food shall be
provided with overhead protection.
(o)
Except for areas used only for the loading of
water or the discharge of sewage and other liquid waste,
through the use of a closed system of hoses, servicing
areas shall be provided with overhead protection.
(p)
Exterior walking and driving surfaces shall be
graded to drain.
(q)
Outdoor refuse areas shall be constructed in
accordance with law and shall be curbed and graded to drain
to collect and dispose of liquid waste that result from the
refuse and from cleaning the area and waste receptacles.
(r)
Establishment operations shall be separated from
any living or sleeping quarters by complete partitioning
and shall have no direct opening into any living or
sleeping quarters, except through a solid, tight-fitting
and self-closing door.
Entrance into the establishment
shall not be through any livin9 or sleeping quarters.
[Eff
2/24/2014; am and comp
AUG 24 2025
(Auth: HRS §321-
11)
(Imp: HRS §321-11)