HAR §12-240-2
HAR §12-240-2. Automatic operation
Length: 271 wordsOfficial source
Cite as Haw. Code R. § 12-240-2
Elevator operation
shall be automatic. Each car shall be equipped with a
self-leveling feature that will automatically bring the
car to floor landings within a tolerance of one-half
(1/2) inch or thirteen (13) millimeters under rated
loading to zero loading conditions. This self-leveling
feature shall be automatic and independent of the
operating device and shall correct the overtravel or
undertravel.
[Eff 12/6/90; am and comp
FEB t 5 2019
(Auth:
HRS §397-4)
(Imp:
HRS §397-4)
§12~240-3
Ha11 ca11 buttons.
Call buttons in
elevator lobbies and halls shall be centered at
approximately forty-two (42) inches (1065 millimeters)
above the floor. When situations prohibit mounting at
forty-two (42) inches, in conjunction with ICC All7.l-2009,
hall buttons maybe be mounted between fifteen (15) inches
and forty-eight (48) inches for unobstructed forward reach,
and between twenty-five (25) inches and forty-eight (48)
inches for obstructed forward reach. Such call buttons
shall have visual signals to indicate when each call is
registered and when each call is answered. Call buttons
shall be a minimum of three-fourths (3/4) inch or
nineteen (19) millimeters in the smallest dimension.
The button designating the up direction shall be on top
as shown in Figure 240-1, titled, "Hoistway and
12-240-2
~ 3 2 3 I~··
§12-240-5
Elevator Entrances", dated December 6, 1990, which is
made a part of this chapter, and located at the end of
this chapter. Buttons shall be raised or flush. Objects
mounted or placed beneath hall call buttons shall not
project into the elevator lobby more than four (4) inches
or 100 millimeters.
[Eff 12/6/90; am and
comp
FE9 f 5 2019
(Auth:
HRS §397-4)
(Imp:
HRS
§397-4)