HAR §12-240-4
HAR §12-240-4. Hall lanterns
Cite as Haw. Code R. § 12-240-4
A visible and audible
signal shall be provided at each hoistway entrance to
indicate which car is answering a call. Audible signals
shall sound once for the up direction and twice for the
down direction or shall have verbal annunciators that
say "up" or "down." Visible signals shall have the
following features:
(1)
Hall lantern fixtures shall be mounted so
that their centerline is at least seventy-
two (72) inches or 1830 millimeters above
the lobby floor;
(2)
Visual elements shall be at least two and a
half (2.5) inches or sixty-four (64)
millimeters in the smallest dimension; and
(3)
Signals shall be visible from the
vicinity of the hall call button. In-car
lanterns located in cars, visible from
the vicinity of hall call buttons, and
confirming to the above requirements,
shall be acceptable as shown in Figure
240-1, titled, "Hoistway and Elevator
Entrances," dated December 6, 1990,
which is made a part of this chapter,
and located at the end of this
chapter.
[Eff 12/6/90; am and
comp
FEB f' 5 2019
]
(Auth:
HRS
§397-4)
(Imp:
HRS §397-4)