a) Each
entrance to a radiation room at a panoramic irradiator shall have a door or
other physical barrier to prevent inadvertent entry of personnel if the sources
are not in the shielded position. Product conveyer systems may serve as
barriers as long as they reliably and consistently function as a barrier. It
shall not be possible to move the sources out of their shielded position if the
door or barrier is open. Opening the door or barrier while the sources are
exposed shall cause the sources to return promptly to their shielded position.
The personnel entrance door or barrier shall have a lock that is operated by
the same key used to move the sources. The doors and barriers shall not
prevent any person in the radiation room from leaving.
b) In
addition, each entrance to a radiation room at a panoramic irradiator shall
have an independent backup access control to detect personnel entry while the
sources are exposed. Detection of entry while the sources are exposed shall
cause the sources to return to their fully shielded position and shall also
activate a visible and audible alarm to make the person entering the room aware
of the hazard. The alarm shall also alert at least one other person who is onsite
of the entry. That person shall be trained on how to respond to the alarm and
prepared to promptly render or summon assistance.
c) A
radiation monitor shall be provided to detect the presence of high radiation
levels in the radiation room of a panoramic irradiator before personnel entry.
The monitor shall be integrated with a personnel access door to prevent room
access when radiation levels are high. Attempted personnel entry while the
monitor measures high radiation levels shall activate the alarm described in
subsection (b). The monitor may be located in the entrance (normally referred
to as the maze) but not in the direct radiation beam.
d) Before
the sources move from their shielded position in a panoramic irradiator, the
source control shall automatically activate conspicuous visible and audible
alarms to alert personnel in the radiation room that the sources will be moved
from their shielded position. The alarms shall give personnel enough time to
leave the room before the sources leave the shielded position.
e) Each
radiation room at a panoramic irradiator shall have a clearly visible and
readily accessible control that would allow a person in the room to make the
sources return to their fully shielded position.
f) Each
radiation room of a panoramic irradiator shall contain a control that prevents
the sources from moving from the shielded positions unless the control has been
activated and the door or barrier to the radiation room has been closed within
a pre-set time after activation of the control.
g) Each
entrance to the radiation room of a panoramic irradiator and each entrance to
the area within the personnel access barrier of an underwater irradiator shall
be posted as required by 32 Ill. Adm. Code 340.920. Radiation postings for
panoramic irradiators shall comply with the posting requirements of 32 Ill.
Adm. Code 340.920, except that signs may be removed, covered, or otherwise made
inoperative when the sources are fully shielded.
h) If
the radiation room of a panoramic irradiator has roof plugs or other movable
shielding, it shall not be possible to operate the irradiator unless the
shielding is in its proper location. This requirement may be met by interlocks
that prevent operation if shielding is not placed properly or by an operating
procedure requiring inspection of shielding before operating.
i) Underwater
irradiators shall have a personnel access barrier around the pool that shall be
locked to prevent access when the irradiator is not attended. Only operators
and facility management shall have access to keys to the personnel access
barrier. There shall be an intrusion alarm to detect unauthorized entry when
the personnel access barrier is locked. Activation of the intrusion alarm
shall alert a person (not necessarily onsite) who is prepared to respond or
summon assistance.