32 Ill. Adm. Code 346.250
Shielding
Section 346.250 Shielding
a) The
radiation dose rate in areas that are normally occupied during operations of a
panoramic irradiator may not exceed 0.02 millisievert (2 millirems) per hour at
any location 30 centimeters or more from the wall of the room when the sources
are exposed. The dose rate shall be averaged over an area not to exceed 100
square centimeters having no linear dimensions greater than 20 cm. Areas where
the radiation dose rate exceeds 0.02 millisievert (2 millirems) per hour shall
be locked, roped off or posted.
b) The
radiation dose at 30 centimeters over the edge of the pool of a pool irradiator
may not exceed 0.02 millisievert (2 millirems) per hour when the sources are in
fully shielded position.
c) The
radiation dose rate at 1 meter from the shield of a dry-source-storage
panoramic irradiator when the source is shielded may not exceed 0.02
millisievert (2 millirems) per hour and at 5 centimeters from the shield may
not exceed 0.2 millisievert (20 millirems) per hour.