32 Ill. Adm. Code 346.370
Power Failures
Section 346.370 Power Failures
a) If
electrical power at a panoramic irradiator is lost for longer than 10 seconds,
the sources shall automatically return to the shielded position.
b) The
lock on the door of the radiation room of a panoramic irradiator shall not be
deactivated by a power failure.
c) During
a power failure, the area of any irradiator where the sources are located may
be entered only when using an operable and calibrated radiation survey meter.
d) If
non-electrical power is used to control or operate any irradiator safety
feature, failure of that power source shall automatically return the radiation
sources to their fully shielded position.