32 Ill. Adm. Code 346.390
Design Requirements
Section 346.390 Design Requirements
Irradiators whose construction begins after December 1, 2005, shall meet the design requirements of this Section.
a) Shielding.
For panoramic irradiators, the licensee shall design shielding walls to meet generally
accepted building code requirements for reinforced concrete and design the
walls, wall penetrations, and entranceways to meet the radiation shielding
requirements of Section 346.250. If the irradiator will use more than 2 x 10
17
becquerels (5 million curies) of activity, the licensee shall evaluate the
effects of heating of the shielding by the irradiator sources.
b) Foundations.
For panoramic irradiators, the licensee shall design the foundation, with
consideration given to soil characteristics, to ensure it is adequate to
support the weight of the facility shield walls.
c) Pool
integrity. For pool irradiators, the licensee shall design the pool to assure
that it is leak resistant, that it is strong enough to bear the weight of the
pool water and shipping casks, that a dropped cask would not fall on sealed
sources, that all outlets or pipes meet the requirements of Section 346.330(b)
and that metal components are metallurgically compatible with other components
in the pool.
d) Water
handling system. For pool irradiators, the licensee shall verify that the
design of the water purification system is adequate to meet the requirements of
Section 346.330(e). The system shall be designed so that water leaking from
the system does not drain to unrestricted areas without being monitored.
e) Radiation
monitors. For all irradiators, the licensee shall evaluate the location and
sensitivity of the monitor to detect sources carried by the product conveyor
system as required by Section 346.290(a). The licensee shall verify that the
product conveyor is designed to stop before a source on the product conveyor
would cause a radiation overexposure to any person. For pool irradiators, if
the licensee uses radiation monitors to detect contamination under Section
346.590(b), the licensee shall verify that the design of radiation monitoring
systems to detect pool contamination included sensitive detectors located close
to where contamination is likely to concentrate.
f) Source
rack. For pool irradiators, the licensee shall verify that there are no
crevices on the source or between the source and source holder that would
promote corrosion on a critical area of the source. For panoramic irradiators,
the licensee shall determine that source rack drops due to loss of power will
not damage the source rack and that source rack drops due to failure of cables
(or alternative means of support) will not cause loss of integrity of sealed
sources. For panoramic irradiators, the licensee shall review the design of
the mechanism that moves the sources to assure that the likelihood of a stuck
source is low and that, if the rack sticks, a means exists to free it with
minimal risk to personnel.
g) Access
control. For panoramic irradiators, the licensee shall verify from the design
and logic diagram that the access control system will meet the requirements of
Section 346.230.
h) Fire
protection. For panoramic irradiators, the licensee shall verify that the
number, location and spacing of the smoke and heat detectors are appropriate to
detect fires and that the detectors are protected from mechanical and radiation
damage. The licensee shall verify that the design of the fire extinguishing
system provides the necessary discharge patterns, densities, and flow
characteristics for complete coverage of the radiation room and that the system
is protected from mechanical and radiation damage.
i) Source
return. For panoramic irradiators, the licensee shall verify that the source
rack will automatically return to the fully shielded position if offsite power
is lost for more than 10 seconds.
j) Seismic.
For panoramic irradiators to be built in seismic areas, the licensee shall
design the reinforced concrete radiation shields to retain their integrity in
the event of an earthquake by designing to the seismic requirements of an
appropriate source, such as Chapter 21, "Special Provisions for Seismic
Design", of the American Concrete Institute Standard "Building Code
Requirements for Reinforced Concrete" (ACI 318-89) or local building codes,
whichever is most current.
k) Wiring.
For panoramic irradiators, the licensee shall verify that electrical wiring and
electrical equipment in the radiation room are selected to minimize failures
due to prolonged exposure to radiation.