32 Ill. Adm. Code 346.410
Construction Monitoring and Acceptance Testing
Section 346.410 Construction Monitoring and Acceptance Testing
The requirements of this Section shall be met by irradiators
whose construction begins after December 1, 2005. The requirements shall be
met prior to loading sources.
a) Shielding.
For panoramic irradiators, the licensee shall monitor the construction of the
shielding to verify that its construction meets design specifications and
generally accepted building code requirements for reinforced concrete.
b) Foundations.
For panoramic irradiators, the licensee shall monitor the construction of the
foundations to verify that their construction meets design specifications.
c) Pool
integrity. For pool irradiators, the licensee shall verify that the pool meets
design specifications and shall test the integrity of the pool. The licensee
shall verify that outlets and pipes meet the requirements of Section 346.330(b)
of this Part.
d) Water
handling systems. For pool irradiators, the licensee shall verify that the
water purification system, the conductivity meter and the water level
indicators operate properly.
e) Radiation
monitors. For all irradiators, the licensee shall verify the proper operation
of the monitor to detect sources carried on the product conveyor system and the
related alarms and interlocks required by Section 346.290(a) of this Part. For
pool irradiators, the licensee shall verify the proper operation of the
radiation monitors and the related alarm if used to meet Section 346.590(b) of
this Part. For underwater irradiators, the licensee shall verify the proper
operation of the over-the-pool monitor, alarms, and interlocks required by
Section 346.290(b) of this Part.
f) Source
rack. For panoramic irradiators, the licensee shall test the movement of the
source racks for proper operation prior to source loading. Testing shall
include source rack lowering due to simulated loss of power. For all
irradiators with product conveyor systems, the licensee shall observe and test
the operation of the conveyor system to assure that the requirements in Section
346.350 of this Part are met for protection of the source rack and the
mechanism that moves the rack. Testing shall include tests of any limit
switches and interlocks used to protect the source rack and mechanism that
moves the rack from moving product carriers.
g) Access
control. For panoramic irradiators, the licensee shall test the completed
access control system to assure that it functions as designed and that all
alarms, controls and interlocks work properly.
h) Fire
protection. For panoramic irradiators, the licensee shall test the ability of
the heat and smoke detectors to detect a fire, to activate alarms, and to cause
the source rack to automatically become fully shielded. The licensee shall
test the operability of the fire extinguishing system.
i) Source
return. For panoramic irradiators, the licensee shall demonstrate that the
source racks can be returned to their fully shielded positions without offsite
power.
j) Computer
systems. For panoramic irradiators that use a computer system to control the
access control system, the licensee shall verify that the access control system
will operate properly if offsite power is lost and shall verify that the
computer has security features that prevent an irradiator operator from
commanding the computer to override the access control system when it is
required to be operable.
k) Wiring.
For panoramic irradiators, the licensee shall verify that the electrical wiring
and electrical equipment that were installed meet the design specifications.