32 Ill. Adm. Code 390.30
Operating Procedures and Instructions
Section 390
Section 390.30 Operating
Procedures and Instructions
a) Each registrant shall inform individuals working in or
frequenting any portion of a restricted area as to the presence of radiation or
particle accelerators; instruct those individuals in safety problems associated
with those areas and in precautions or procedures to minimize radiation
exposure; instruct the individuals in the provisions of Agency regulations for
the protection of personnel from exposures to radiation; and advise the
individuals of reports of radiation exposure that those individuals may request
pursuant to this Part.
b) Each particle accelerator facility shall be under the
administrative control of a radiation protection officer or radiation safety
committee that will be responsible for the safe operation of the accelerator.
c) Written operating and emergency procedures, as well as
specified safety rules, shall be established for each accelerator facility and
approved by the radiation protection officer.
d) Personnel who operate or maintain particle accelerators shall
be familiar with, and have available a copy of, the written operating and
emergency procedures.
e) No individual shall be permitted to operate or maintain an
accelerator until the individual has received at least the training specified
in Section 390.70.
f) Modification, repairs or preventive maintenance on accelerator
components or safety interlocks may be performed only by or under the direct
supervision of individuals who have received at least the training specified in
Section 390.70.
g) Provisions shall be made at each accelerator control console
to display the name of the individual who is authorized to operate the
accelerator. Only the individual whose name is displayed may turn on the
accelerator or open entrances to high radiation areas.
h) The radiation safety officer shall maintain a current list of
all personnel who are qualified to operate or service the particle accelerator.
i) No registrant shall permit a particle accelerator to operate
at any time with a safety interlock bypassed, except for necessary testing.
Upon circumvention of an interlock, the registrant shall maintain records
showing the date and reasons for bypassing the interlock. A sign shall be
posted at the personnel entrance door being bypassed and this condition
terminated as soon as possible.
j) Additional Requirements. The Agency may, by rule, regulation
or order, impose upon any registrant requirements in addition to those
established in this Part as it deems appropriate or necessary to minimize
danger to public health and safety or property.