32 Ill. Adm. Code 601.230
Disposal Unit Design and Construction
Section 601.230 Disposal Unit Design and Construction
a) Disposal
units shall be designed and constructed, based on accepted engineering
principles and practices, to:
1) Minimize,
to the extent practicable, the contact of standing water with waste during
disposal and the contact of percolating or standing water with wastes after
disposal.
2) Be
compatible with the expected waste characteristics, methods of operation, and
proposed methods of closure and stabilization.
3) Withstand
all natural phenomena, such as precipitation, earthquakes and tornadoes, that
are expected to occur for 500 years.
4) Incorporate
multiple engineered safety features, such as, but not limited to, placing a
cover over disposal units, using backfill that adds structural strength and
reinforcing units with manufactured materials that provide structural support,
prevent the release of waste and waste constituents and prevent inadvertent
intrusion.
5) Incorporate
design elements that will allow operation of the units in such a manner that
the amount of waste on site that is not yet permanently disposed of, as well as
the time that waste is held on site prior to disposal, will be minimized.
6) Accommodate
waste that cannot be packaged in standard containers, e.g., reactor components,
contaminated steel.
7) Maintain
their structural integrity regardless of the physical form of the waste.
8) Allow
characterization, modeling, analysis and evaluation of the unit's ability to
contain waste.
b) Disposal
unit covers shall be designed to minimize water infiltration to the extent
practicable, to direct percolating or surface water away from the disposed
waste, and to resist degradation by surface geologic processes and biotic
activity.
c) Disposal
unit design shall not incorporate the use of shallow land burial or underground
injection wells and shall provide for the use of above-ground units or other
designs to provide greater and safer confinement of low-level radioactive
waste.
d) Disposal
units made of manufactured materials shall be designed and constructed, using
accepted engineering principles and practices, to ensure that the tensile
stress in the manufactured materials never exceeds the level that will cause
the materials to fail.
e) Disposal
units shall be constructed of materials that will not interact with each other,
any surrounding earth, backfill, cover material or base grade material in such
a manner as to compromise the ability of the materials to perform their intended
function.
f) If
intruder barriers are required by Section 601.250(b), disposal units shall be
designed and constructed with intruder barriers designed to last at least 500
years.