35 Ill. Adm. Code 204.420
Good Engineering Practice
Section 204.420 Good Engineering Practice
a) "Good
engineering practice", with respect to stack height, means the greater of:
1) 65
meters, measured from the ground-level elevation at the base of the stack;
2) The
following:
A) For a
stack in existence on January 12, 1979, and for which the owner or operator had
obtained all necessary preconstruction approvals or permits required under 40
CFR 51 and 52 (incorporated by reference in Section 204.100):
H
g
= 2.5H,
provided the owner or operator
produces evidence that this equation was actually relied on in establishing an
emission limitation;
B) For
all other stacks:
H
g
= H + 1.5L
where:
H
g
= good engineering
practice stack height, measured from the ground-level elevation at the base of
the stack;
H = height of nearby structure or
structures measured from the ground-level elevation at the base of the stack;
L = lesser dimension, height, or
projected width of nearby structure or structures provided, that USEPA or the
Agency may require the use of a field study or fluid model to verify good engineering
practice stack height for the source; or
3) The
height demonstrated by a fluid model or a field study approved by USEPA or the
Agency that ensures the emissions from a stack do not result in excessive
concentrations of any air pollutant as a result of atmospheric downwash, wakes,
or eddy effects created by the source itself, nearby structures, or nearby
terrain features.
b) For
purposes of this definition, "stack" means any point in a source
designed to emit solids, liquids, or gases into the air, including a pipe or
duct but not including flares.