35 Ill. Adm. Code 215.444
Process Unit Turnarounds
Section 215
Section 215.444 Process Unit
Turnarounds
a) No owner or operator of a petroleum refinery shall cause or
allow a refinery process unit turnaround except in compliance with an operating
procedure as approved by the Agency.
b) Unless a procedure is already on file with the Agency as part
of an approved operating permit no later than November 1, 1979, the owner or
operator of a petroleum refinery shall submit to the Agency for approval a
detailed procedure for reducing emissions of volatile organic material during
refinery process unit turnarounds from organic material with a vapor pressure
of 10.34 kPa (1.5 psia) or greater at 294.3 K (70 F). The Agency shall not
approve the procedure unless it provides for:
1) Depressurization of the refinery process unit or vessel to a
flare, refinery fuel gas system or other equipment or system of equal emission
control, as approved by the Agency, until the internal pressure from the vessel
or unit is less than 5.0 psig before allowing the vessel to be vented to the
atmosphere;
2) Recordkeeping of the following items:
A) Each date that a refinery unit or vessel is shut down; and
B) The total estimated quantity of volatile organic material
emitted to the atmosphere and the duration of the emission in hours.