35 Ill. Adm. Code 215.483
Material Storage and Transfer
Section 215
Section 215.483Â Material
Storage and Transfer
The owner or operator of a
pharmaceutical manufacturing plant shall:
a)Â Â Â Â Â Â Â Â Provide a vapor balance system that is at least 90.0 percent
effective in reducing volatile organic material emissions from truck or railcar
deliveries to storage tanks with capacities equal to or greater than 7.57m
(2,000 gallons) that store volatile organic liquids with vapor pressures
greater than 28.0 kPa (4.1 psi) at 294.3 K (70 F); and
b)Â Â Â Â Â Â Â Â Install, operate and maintain pressure/vacuum conservation
vents set at 0.2 kPa (0.03 psi) or greater on all storage tanks that store
volatile organic liquids with vapor pressures greater than 10 kPa (1.5 psi) at
294.3 K (70 F).