35 Ill. Adm. Code 218.413
Emission Limitations and Control Requirements for Letterpress Printing Lines
Section 218.413 Emission Limitations and Control
Requirements for Letterpress Printing Lines
a) No
owner or operator of letterpress printing lines subject to the requirements of
this Subpart shall:
1) Cause
or allow the operation of any heatset web letterpress printing line that meets
the applicability requirements of Section 218.412(a)(1) unless:
A) The
air pressure in the dryer is maintained lower than the air pressure of the
press room, such that air flow through all openings in the dryer, other than
the exhaust, is into the dryer at all times when the printing line is
operating;
B) An
afterburner is installed and operated so that VOM emissions (excluding methane
and ethane) from the press dryer exhausts are reduced as follows:
i) By
90 percent, by weight, for afterburners first constructed at the source prior
to January 1, 2010;
ii) By
95 percent, by weight, for afterburners first constructed at the source on or
after January 1, 2010; or
iii) To a
maximum afterburner exhaust outlet concentration of 20 ppmv (as carbon);
C) The
afterburner complies with all monitoring provisions specified in Section
218.416(a) of this Subpart; and
D) The
afterburner is operated at all times when the printing line is in operation,
except the afterburner may be shut down between November 1 and April 1 as
provided in Section 218.107 of this Part;
2) Cause
or allow the use of a cleaning solution on any letterpress printing line
unless:
A) The
VOM content of the as-used cleaning solution is less than or equal to 70
percent, by weight; or
B) The
VOM composite partial vapor pressure of the as-used cleaning solution is less
than 10 mmHg at 20
o
C (68
o
F);
3) Cause
or allow VOM-containing cleaning materials, including used cleaning towels,
associated with any letterpress printing line to be kept, stored, or disposed
of in any manner other than in closed containers, except when specifically in
use.
b) An
owner or operator of a heatset web letterpress printing line subject to the
requirements of subsection (a)(1)(B) of this Section may use a control device
other than an afterburner, if:
1) The
control device reduces VOM emissions from the press dryer exhausts as follows:
A) By 90
percent, by weight, for control devices first constructed at the source prior
to January 1, 2010;
B) By 95
percent, by weight, for control devices first constructed at the source on or
after January 1, 2010; or
C) To a
maximum control device exhaust outlet concentration of 20 ppmv (as carbon);
2) The
owner or operator submits a plan to the Agency detailing appropriate monitoring
devices, test methods, recordkeeping requirements, and operating parameters for
the control device; and
3) The
use of the control device in accordance with this plan is approved by the
Agency and USEPA as federally enforceable permit conditions.