35 Ill. Adm. Code 218.415
Testing for Letterpress Printing Lines
Section 218.415 Testing for Letterpress Printing Lines
a) Testing
to demonstrate compliance with the requirements of Section 218.413 of this
Subpart shall be conducted by the owner or operator by January 1, 2012, unless
such testing has been conducted within the two years immediately preceding
January 1, 2012. Thereafter, testing shall be conducted by the owner or
operator within 90 days after a request by the Agency, or as otherwise
specified in this Subpart. Such testing shall be conducted at the expense of
the owner or operator, and the owner or operator shall notify the Agency in
writing 30 days in advance of conducting such testing to allow the Agency to be
present during such testing.
b) The
methods and procedures of Section 218.105(d) and (f) shall be used for testing
to demonstrate compliance with the requirements of Section 218.413(a)(1)(B) or
(b)(1) of this Subpart, as follows:
1) To
select the sampling sites, Method 1 or 1A, as appropriate, 40 CFR
60, appendix A, incorporated by reference in Section 218.112 of this Part. The
sampling sites for determining efficiency in reducing VOM from the dryer
exhaust shall be located between the dryer exhaust and the control device
inlet, and between the outlet of the control device and the exhaust to the
atmosphere;
2) To
determine the volumetric flow rate of the exhaust stream, Method 2, 2A, 2C, or
2D, as appropriate, 40 CFR 60, appendix A, incorporated by reference in Section
218.112 of this Part;
3) To
determine the VOM concentration of the exhaust stream entering and exiting the
control device, Method 25 or 25A, as appropriate, 40 CFR 60, appendix A,
incorporated by reference in Section 218.112 of this Part. For thermal and
catalytic afterburners, Method 25 must be used except under the following
circumstances, in which case Method 25A must be used:
A) The allowable
outlet concentration of VOM from the control device is less than 50 ppmv, as
carbon;
B) The
VOM concentration at the inlet of the control device and the required level of
control result in exhaust concentrations of VOM of 50 ppmv, or less, as carbon;
and
C) Due to
the high efficiency of the control device, the anticipated VOM concentration at
the control device exhaust is 50 ppmv or less, as carbon, regardless of inlet
concentration. If the source elects to use Method 25A under this option, the
exhaust VOM concentration must be 50 ppmv or less, as carbon, and the required
destruction efficiency must be met for the source to have demonstrated
compliance. If the Method 25A test results show that the required destruction
efficiency apparently has been met, but the exhaust concentration is above 50
ppmv, as carbon, a retest is required. The retest shall be conducted using
either Method 25 or Method 25A. If the retest is conducted using Method 25A
and the test results again show that the required destruction efficiency
apparently has been met, but the exhaust concentration is above 50 ppmv, as
carbon, the source must retest using Method 25;
4) Notwithstanding
the criteria or requirements in Method 25 which specifies a minimum probe
temperature of 129
°
C (265
o
F),
the probe must be heated to at least the gas stream temperature of the dryer
exhaust, typically close to 176.7
o
C (350
o
F);
5) During
testing, the printing lines shall be operated at representative operating
conditions and flow rates; and
6) During
testing, an air flow direction indicating device, such as a smoke stick, shall
be used to demonstrate 100 percent emissions capture efficiency for the dryer
in accordance with Section 218.413(a)(1)(A) of this Subpart.
c) Testing
to demonstrate compliance with the VOM content limitations in Section
218.413(a)(2)(A) of this Subpart, and to determine the VOM content of cleaning
solvents, cleaning solutions, and inks (pursuant to the requirements of Section
218.417(b)(1)(B) of this Subpart), shall be conducted upon request of the
Agency, or as otherwise specified in this Subpart, as follows:
1) The
applicable test methods and procedures specified in Section 218.105(a) of this
Part shall be used; provided, however, Method 24, incorporated by reference in
Section 218.112 of this Part, shall be used to demonstrate compliance; or
2) The
manufacturer's specifications for VOM content for cleaning solvents and inks
may be used if such manufacturer's specifications are based on results of tests
of the VOM content conducted in accordance with methods specified in Section
218.105(a) of this Part; provided, however, Method24 shall be used to determine
compliance.
d) Testing
to demonstrate compliance with the requirements of Section 218.413(b) of this
Subpart shall be conducted as set forth in the owner or operator's plan
approved by the Agency and USEPA as federally enforceable permit conditions
pursuant to Section 218.413(b) of this Subpart.
e) Testing
to determine the VOM composite partial vapor pressure of cleaning solvents,
cleaning solvent concentrates, and as-used cleaning solutions shall be
conducted in accordance with the applicable methods and procedures specified in
Section 218.110 of this Part.