35 Ill. Adm. Code 218.416
Monitoring Requirements for Letterpress Printing Lines
Section 218.416 Monitoring Requirements for Letterpress
Printing Lines
a) Afterburners
for Heatset Web Letterpress Printing Lines. If an afterburner is used to
demonstrate compliance, the owner or operator of a heatset web letterpress
printing line subject to Section 218.413(a)(1)(B) of this Subpart shall:
1) Install,
calibrate, maintain, and operate temperature monitoring devices with an
accuracy of 3
o
C or 5
o
F on the afterburner in accordance
with Section 218.105(d)(2) of this Part and in accordance with the
manufacturer's specifications. Monitoring shall be performed at all times when
the afterburner is operating; and
2) Install,
calibrate, operate, and maintain, in accordance with manufacturer's
specifications, a continuous recorder on the temperature monitoring devices,
such as a strip chart, recorder or computer, with at least the same accuracy as
the temperature monitor.
b) Other
Control Devices for Heatset Web Letterpress Printing Lines. If a control
device other than an afterburner is used to demonstrate compliance, the owner
or operator of a heatset web letterpress printing line subject to this Subpart
shall install, maintain, calibrate, and operate such monitoring equipment as
set forth in the owner or operator's plan approved by the Agency and USEPA
pursuant to Section 218.413(b) of this Subpart.
c) Cleaning
Solution
1) The
owner or operator of any letterpress printing line relying on the VOM content
of the cleaning solution to comply with Section 218.413(a)(2)(A) of this
Subpart must:
A) For
cleaning solutions that are prepared at the source with equipment that
automatically mixes cleaning solvent and water (or other non-VOM):
i) Install,
operate, maintain, and calibrate the automatic feed equipment in accordance
with manufacturer's specifications to regulate the volume of each of the
cleaning solvent and water (or other non-VOM), as mixed; and
ii) Pre-set
the automatic feed equipment so that the consumption rates of the cleaning
solvent and water (or other non-VOM), as applied, comply with Section
218.413(a)(2)(A) of this Subpart;
B) For
cleaning solutions that are not prepared at the source with automatic feed
equipment, keep records of the usage of cleaning solvent and water (or other
non-VOM) as set forth in Section 218.417(c)(2) of this Subpart.
2) The
owner or operator of any letterpress printing line relying on the vapor
pressure of the cleaning solution to comply with Section 218.413(a)(2)(B) of
this Subpart must keep records for such cleaning solutions used on any such
lines as set forth in Section 218.417(e)(2)(C) of this Subpart.