35 Ill. Adm. Code 219.433
Performance and Testing Requirements
Section 219
Section 219.433 Performance and Testing Requirements
a) For
the purpose of demonstrating compliance with the TRE index value in Section
219.432(c) of this Subpart, an engineering assessment shall be made to
determine process vent stream flow rate, net heating value, and VOM emission
rate for the representative operating conditions expected to yield the lowest
TRE index value. The source shall also calculate the TRE index values pursuant
to the equations contained within Appendix G (b)(1) of this Part.
1) If
the TRE index value calculated using such engineering assessment and the TRE
equation in Appendix G (b)(1) of this Part is greater than 4.0, then the owner
or operator is exempt from performing the measurements specified in Appendix G
(a) of this Part.
2) If
the TRE index value calculated using such engineering assessment and the TRE
equation in Appendix G (b)(1) of this Part is less than or equal to 4.0, then
the owner or operator shall perform the measurements specified in Appendix G(a)
of this Part. An owner or operator of a source may, in the alternative, elect
to comply with the control requirements specified in Section 219.432 of this
Subpart rather than performing the measurements in Appendix G(a) of this Part.
3) An
engineering assessment shall include, but is not limited to, the following:
A) Previous
test results, provided the tests are representative of current operating
practices at the chemical manufacturing process unit;
B) Bench-scale
or pilot-scale test data of the process under representative operating
conditions;
C) Maximum
flow rate, as stated within a permit limit, applicable to the process vent;
D) Design
analysis based on accepted chemical engineering principles, measurable process
parameters, or physical or chemical laws or properties. Examples of analytical
methods include, but are not limited to, the following:
i) Use
of material balances based on process stoichiometry to estimate maximum VOM
concentrations;
ii) Estimation
of maximum flow rate based on physical equipment design such as pump or blower
capacities;
iii) Estimation
of VOM concentrations based on saturation conditions; and
iv) Estimation
of maximum expected net heating value based on the stream concentration of each
organic compound, or, alternatively, as if all VOM in the stream were the
compound with the highest heating value.
E) All data,
assumptions, and procedures used in the engineering assessment shall be
documented.
b) For the
purpose of demonstrating compliance with the control requirements in Section 219.432
of this Subpart, the chemical manufacturing process unit shall be run at representative
operating conditions and flow rates during any performance test.
c) The following
methods in 40 CFR 60, incorporated by reference at Section 219.112 of this
Part, shall be used to demonstrate compliance with the reduction efficiency requirement
listed in Section 219.432(a)(1) of this Subpart.
1) Method
1 or 1A, incorporated by reference at Section 219.112 of this Part, as
appropriate, for selection of the sampling sites. The control device inlet
sampling site for determination of vent stream molar composition or VOM
content, less methane and ethane, reduction efficiency shall be located after
the last recovery device but prior to the inlet of the control device, prior to
any dilution of the process vent stream, and prior to release to the atmosphere.
2) Method
2, 2A, 2C or 2D, incorporated by reference at Section 219.112 of this Part, as
appropriate, for determination of gas stream volumetric flow rate.
3) The emission
rate correction factor, integrated sampling, and analysis procedure of Method 3,
incorporated by reference at Section 219.112 of this Part, shall be used to
determine the oxygen concentration (%O
2d
) for the purpose of determining
compliance with the 20 ppmv limitation. The sampling site for determining
compliance with the 20 ppmv limitation shall be the same site used for the VOM
samples, and samples shall be taken at the same time that the VOM samples are taken.
The VOM concentration corrected to 3 percent oxygen (C[c]) shall be computed
using the following formula:
where:
C
c
=
Concentration of VOM (minus methane and ethane) corrected
to 3 percent O
2
dry basis, ppmv.
C
VOM
=
Concentration of VOM (minus methane and ethane), dry
basis, ppmv
%O
2d
=
Concentration of oxygen, dry basis, percent by volume.
4) Method
18, incorporated by reference at Section 219.112 of this Part, to determine the
concentration of VOM, less methane and ethane, at the outlet of the control
device when determining compliance with the 20 ppmv limitation in Section 219.432(a)(1)
of this Subpart, or at both the control device inlet and outlet when the
reduction efficiency of the control device is to be determined.
A) The minimum
sampling time for each run shall be 1 hour in which either an integrated sample
or four grab samples shall be taken. If grab sampling is used then the samples shall
be taken at 15-minute intervals.
B) The emission
reduction (R) of VOM, less methane and ethane, shall be determined using the
following formula:
where:
R
=
Emission reduction, percent by weight.
E
i
=
Mass rate of VOM (minus
methane and ethane) entering the control device, kg VOM/hr.
E
o
=
Mass rate of VOM, less methane and ethane discharged to
the atmosphere, kg VOM/hr.
C)
The mass rates
of VOM (E
i
, E
o
) shall be computed using the following
formula:
where:
C
ij
, C
oj
=
Concentration of sample component "j" of the gas
stream at the inlet and outlet of the control device, respectively, dry
basis, ppmv.
M
ij
, M
oj
=
Molecular weight of sample component "j" of the
gas stream at the inlet and outlet of the control device, respectively, grams
per gram-mole.
Q
i
, Q
o
=
Flow rate of gas stream at the inlet and outlet of the
control device, respectively, dry scm/min.
K
2
=
2.494 x 10
-6
(liters per minute) (gram-mole
per scm) (kg/g)(min/hr), where standard temperature for (gram-mole per scm)
is 20° C.
D)
The
representative VOM concentration (C
VOM
) is the sum of each of the
individual components of VOM (C
j
) and shall be computed for each run
using the following:
where:
C
VOM
=
Concentration of VOM (minus methane and ethane), dry
basis, ppmv.
C
j
=
Concentration of sample component "j", dry
basis, ppmv.
n
=
Number of components in the sample.
5) When
a boiler or process heater with a design heat input capacity of 44 megawatts or
greater, or a boiler or process heater into which the process vent stream is
introduced with the primary fuel, is used to comply with the control
requirements, an initial performance test is not required.
d) When
a flare is used to comply with the control requirements of this rule, the flare
shall comply with the requirements of 40 CFR 60.18, incorporated by reference
at Section 219.112 of this Part.