35 Ill. Adm. Code 219.504
Monitoring Requirements for Batch Operations
Section 219
Section 219.504 Monitoring
Requirements for Batch Operations
a) Every owner or operator using an afterburner to comply with
Section 219.501 of this Subpart shall install, calibrate, maintain and operate,
according to manufacturer's specifications, temperature monitoring devices with
an accuracy of
+
1 percent of the temperature being measured expressed
in degrees Celsius, equipped with continuous recorders.
1) Where a catalytic afterburner is used, temperature monitoring
devices shall be installed in the gas stream immediately before and after the
catalyst bed.
2) Where an afterburner other than a catalytic afterburner is
used, a temperature monitoring device shall be installed in the combustion
chamber.
b) Every owner or operator using a flare to comply with Section
219.501 of this Subpart shall install, calibrate, maintain and operate,
according to manufacturer's specifications, a heat sensing device, such as an
ultra-violet beam sensor or thermocouple, at the pilot light to indicate
continuous presence of a flame.
c) Every owner or operator using a scrubber to comply with this
Section 219.501 of this Subpart shall install, calibrate, maintain, and
operate, according to manufacturer's specifications, the following:
1) A temperature monitoring device for scrubbant liquid having an
accuracy of
+
1 percent of the temperature being monitored expressed in
degrees Celsius and a specific gravity device for scrubbant liquid, each
equipped with a continuous recorder; or
2) A VOM monitoring device used to indicate the concentration of
VOM exiting the control device based on a detection principle such as infra-red
photoionization, or thermal conductivity, each equipped with a continuous
recorder.
d) Every owner or operator using a condenser to comply with
Section 219.501 of this Subpart shall install, calibrate, maintain, and
operate, according to manufacturer's specifications, the following:
1) A condenser exit temperature monitoring device equipped with a
continuous recorder and having an accuracy of
+
1 percent of the
temperature being monitored expressed in degrees Celsius; or
2) A VOM monitoring device used to indicate the concentration of
VOM such as infra-red, photoionization, or thermal conductivity, each equipped
with a continuous recorder.
e) Every owner or operator using a carbon adsorber to comply with
this Subpart shall install, calibrate, maintain, and operate, according to the
manufacturer's specifications, the following equipment:
1) An integrating regeneration steam flow monitoring device
having an accuracy of
+
10 percent, and a carbon bed temperature
monitoring device having an accuracy of
+
1 percent of the temperature
being monitored expressed in degrees Celsius, both equipped with a continuous
recorder; or
2) A VOM monitoring device used to indicate the concentration
level of VOM exiting such device based on a detection principle such as
infra-red, photoionization, or thermal conductivity, each equipped with a
continuous recorder.
f) Every owner or operator using a boiler or process heater with
a design heat input capacity less than 44 Mw to comply with Section 219.501 of
this Subpart shall install, calibrate, maintain, and operate, according to the
manufacturer's specifications, a temperature monitoring device in the firebox
with an accuracy of
+
1 percent of the temperature being measured
expressed in degrees Celsius, equipped with a continuous recorder. Any boiler
or process heater in which all process vent streams are introduced with primary
fuel is exempt from this requirement.
g) The owner or operator of a process vent shall be permitted to
monitor by an alternative method or may monitor parameters other that those
listed in subsections (a) through (f) of this Section, if approved by the
Agency and USEPA. Such alternative method or parameters shall be contained in
the source's operating permit as federally enforceable permit conditions.
h) Notwithstanding subsections (a) through (g) of this Section,
sources using a scrubber, shell and tube condenser using a non-refrigerated
cooling media, or other control device meeting the criteria of Section
219.501(c) of this Subpart, are required to monitor compliance with the
requirements of this Subpart on and after the earlier to occur of the date such
device is replaced for any reason or December 31, 1999.