35 Ill. Adm. Code 370.1020
Chlorine Disinfection
Section 370
Section 370.1020 Chlorine
Disinfection
a) Type of Feed Equipment
The types of chlorine feed equipment include:
1) Vacuum solution feed by gas;
2) Direct gas feed;
3) Hypochlorite solution positive displacement pump feed;
4) Hypochlorite tablet feed.
b) Selection of Feed Equipment
The selection of the type of chlorine feed equipment shall
take into account operator safety and overall public safety relative to the
proximity of the sewage treatment plant to populated areas and to the security
of the gas cylinder or container storage.
c) Output Capacity of Gas Chlorine Cylinders
Delivery
Rates (lbs of chlorine/day)
Ambient
Temp.
°F
100
pound Cylinder
150
pound Cylinder
1
Ton Container
40
6
9
100
50
14
21
240
60
23.7
35.5
385
70
32
47.5
536
80
41.2
62
700
Some types of vacuum chlorinators can deliver chlorine at rates greater
than those listed above under the same conditions. When designs include rates
in excess of those indicated above, manufacturer's specifications and test
results shall be provided.
d) Standby Equipment and Spare Parts
Standby equipment of sufficient capacity should be available
to replace the largest unit during shutdowns. Spare parts shall be available
for all chlorinators to replace parts which are subject to wear and breakage.
e) Potable Water Supply Protection
An ample supply of water shall be available for operating the
chlorinator. Where a booster pump is required, duplicate equipment should be
provided and, when necessary, also standby power (refer to Section 370.550(a)(4)).
Protection of a potable water supply shall conform to the requirements of
Section 370.550(b)(3). In-line backflow preventers are not acceptable.
f) Chlorine Gas Supply
1) Cylinders
The use of 1-ton containers should be considered where the
average daily chlorine gas consumption is over 150 pounds. All upright
chlorine cylinders shall be strapped securely to prevent tipping.
2) Tank Cars
A) At large installations the use of tank cars, generally
accompanied by evaporators, may be considered. Areawide public safety shall be
evaluated as a part of the considerations. Provision shall be made for a
chlorine supply during tank car switching.
B) The tank car being used for the chlorine supply shall be
located on a dead end, level track that is a dedicated siding. The tank car
shall be protected from accidental bumping by other railway cars by a locked
de-rail device, a closed lock switch, or both. The area shall be clearly
posted "DANGER CHLORINE." The tank car shall be secured by adequate
fencing with locked gates for personnel and rail access.
C) The tank car site shall be provided with an operating platform
at the unloading point that allows for easy access to the protective housing on
the tank car for flexible feed line connection and valve operation. Area
lighting adequate for night time operation and maintenance shall be provided.
3) Scales
A) Scales shall be provided for weighing cylinders and containers
at all plants using chlorine gas.
B) At large plants, indicating and recording scales are
recommended. At a minimum, a platform scale shall be provided. Scales shall
be made of corrosion-resistant material. Scales should be recessed unless
hoisting equipment is provided or the scales are low enough to allow the
cylinders to be rolled onto them.
4) Evaporators
Where manifolding of several cylinders or containers will be
required to evaporate sufficient chlorine, consideration should be given to
liquid drawoff and installation of an evaporator.
5) Leak Detection and Controls
A bottle of ammonium hydroxide solution should be available
for detecting chlorine leaks. Consideration should also be given to the
provision of caustic soda solution reaction tanks for absorbing the contents of
leaking 1-ton containers where such containers are in use. Also, when
cylinders, containers or tank cars are used, a leak repair kit approved by the
Chlorine Institute shall be provided. At installations using over 150 pounds
of chlorine gas per day consideration should be given to the installation of
automatic gas detection and related alarm equipment.
g) Piping and Connections
1) Piping systems should be as simple as possible, and shall be
specially selected and manufactured to be suitable for chlorine service, with a
minimum number of joints. Piping should be well supported and protected
against temperature extremes.
2) The chlorine system piping shall be color coded and labeled to
distinguish it from sulfur dioxide and other plant piping. Where sulfur
dioxide is used, the piping and fittings for chlorine and sulfur dioxide
systems shall be designed so that interconnection between the two systems
cannot occur.
h) Housing
1) Container and Equipment Location
Containers and feed equipment should be located indoors, in a
suitable fire-resistant building. Gas cylinders should be protected from
direct sunlight if not located indoors.
A) Separation
If gas chlorination equipment and chlorine cylinders or
containers are to be housed in a building used for other purposes, the chlorine
cylinders or containers and equipment shall be located in an isolated room.
This room shall not contain any sulfonation equipment, sulfur dioxide cylinders
or other equipment unrelated to chlorination. Common walls to other areas of
the building shall be gastight. Doors to this room shall open only to the
outside of the building and shall be equipped with panic hardware. Rooms shall
be at ground level and shall permit easy access to all equipment. Storage
areas should be separated from the feed area.
B) Inspection Window
A clear gastight window shall be installed in the chlorinator
room to permit the units to be viewed and gauges to be read without entering
the room.
C) Heat
Chlorinator housing facilities shall be provided with a means
of heating so that a temperature of at least 60° F can be maintained. Where
chlorine gas is to be withdrawn from cylinders or containers, the cylinders or
containers shall be maintained at essentially room temperature. The room shall
be protected from excessive heat. If liquid chlorine is to be withdrawn from
the cylinders or containers to an evaporator unit, the feed cylinders or
containers may be located in an unheated area.
3) Ventilation For Gas Chlorination Systems
A) Forced, mechanical ventilation shall be installed which will
provide 1 complete air change per minute. The entrance to the air exhaust duct
from the room shall be within 12 inches of the floor and the point of discharge
shall be so located as not to contaminate the air in the immediate vicinity of
the entrance door to the chlorinator room or ventilation inlet or window or
entrance door to any buildings or inhabited areas. Where the public may be
subjected to extensive exposure to chlorine in case of chlorine leaks,
scrubbers may be required on the ventilation discharge.
B) The chlorination room air inlets shall be so located as to provide
cross ventilation with air and at such temperature that will not adversely
affect the chlorination equipment. The vent hose from the chlorinator shall
discharge to the outside atmosphere above grade.
4) Electrical Controls
The controls for the fans and lights shall be provided at
those locations where it is necessary to enter the chlorination room and shall
automatically operate when the door is opened and continue to operate when the
operator enters the room and the door is closed. Provision shall be made for
manual operation of controls from the outside of the room without opening the
door.
5) Outdoor Cabinet Housing
Outdoor shallow cabinet-type units, with wide opening doors,
that are shallow enough not to need or require operator entry, may be used to
house the containers and feed equipment. Use of such cabinets shall be limited
to small plants that provide seasonal disinfection or use less than 10 pounds
of chlorine per day. Only two chlorine gas cylinders of 150 pounds or less on
line may be housed in the cabinets. The following items shall be provided for
in the design:
A) The cabinet structure shall be located on and securely anchored
to a concrete slab sized to allow for safe transport and handling of the cylinders.
The structure and slab shall be capable of withstanding expected wind loadings
on the cabinet. The design of the cabinet support slab shall take into account
the effects of frost and settling due to soil stability. Flexible piping
connections should be considered for lines connected to the cabinet.
B) The cabinet shall be protected from direct sunlight to prevent
overheating of the chlorine cylinders.
C) The cabinet doors shall extend the full width of the long side
of the cabinet structure so that the full interior of the cabinet is exposed
with the door open. Provision shall be made to secure the open doors while the
operator is changing cylinders and maintaining the feed equipment.
D) The cabinet depth shall not exceed 24 inches. The feed
equipment shall be positioned to allow easy access for maintenance and to allow
observation of the gauges and meters.
E) Provision shall be made for chains, wall mounted fastener hooks
or similar means for anchoring the chlorine cylinders to prevent tipping.
F) The cabinet structure shall be corrosion resistant to chlorine
gas.
G) Where electrical power is available, the cabinet should be
placed in a well-lighted area.
i) Respiratory Protection Equipment
Respiratory protection equipment meeting the requirements of
the National Institute for Occupational Safety and Health (NIOSH) shall be
available at all installations where chlorine gas is handled and shall be
stored in a convenient location outside of any room where chlorine is used or
stored. The respiratory protection units shall use compressed air, have at
least a 30-minute capacity, and be compatible with or exactly the same as
NIOSH-approved units used by the local fire department. Instructions for
using, testing, and replacing mask parts shall be posted. At large
installations, consideration should be given to providing acid suits and fire
suits.
j) Application of Chlorine
1) Contact Period
After thorough mixing, a minimum contact period of 15 minutes
at design peak hourly flow or maximum rate of pumpage shall be provided.
2) Chlorinator Dosing Rate Capacity
Chlorinators shall be designed to have a capacity adequate to
produce an effluent that will meet the applicable bacterial limits. Where
necessary to meet the operating ranges, multiple units shall be provided for
adequate peak capacity and for a sufficiently low feed rate on turn down to allow
proper chlorine residual. The chlorination system shall be designed on a
rational basis and calculations justifying the equipment sizing and number of
units shall be submitted for the whole operating range of flow rates, including
the minimum turn down capacity for the type of control to be used. System
design considerations shall include the controlling sewage flow meter
(sensitivity and location), telemetering equipment and chlorinator controls.
For treated normal domestic sewage the following dosing capacity, based on
design average flow, is suggested (see Section 370.520(c)(1)):
Type
of Treatment
Dosage
(mg/l)
Primary Settled Sewerage
20
Lagoon Effluent (unfiltered)
20
Trickling Filter Plant Effluent
10
Lagoon Effluent (filtered)
10
Activated Sludge Plant Effluent
6
Activated Sludge Plants with Chemical Addition
4
Filtered Effluent Following Mechanical Biological Treatment
4
k) Contact Tank
1) Mechanical means of sludge removal is recommended and should
be provided unless multiple chlorine tanks are provided. Portable deck-level
vacuum cleaning equipment may be used for small treatment plants. Provisions
for draining contact tanks not equipped with mechanical sludge removal
equipment shall be provided, with the drain flow returned to process for
treatment.
2) Exception to the requirement of duplicate contact tanks may be
granted if the contact tank follows a sand filter or if the main treatment
works is a waste stabilization pond, with provisions for storing the sewage
flow for several days while the contact tank is being cleaned.
3) Adequate mixing during the chlorine contact period shall be
insured by the installation of adequate baffling, air or other mixing
equipment. Facilities for the retention and removal of floating scum shall be
provided.