35 Ill. Adm. Code 370.300
General Considerations
Section 370
Section 370.300 General
Considerations
a) Type of Sewers
The Agency
will approve plans for new sewer systems and extensions only when designed as
the separate sanitary type in which precipitation runoff and ground water from
foundation drains are excluded. The Agency will not approve the installation
of new combined sewers, except as provided in 35 Ill. Adm. Code 306.302.
b) Design Period
Sewer systems
should be designed for the estimated ultimate tributary population, except in
considering parts of the systems that can be readily increased in capacity.
Similarly, consideration should be given to the maximum anticipated capacity of
institutions, industrial parks, etc.
c) Design Factors
In determining
the required capacities of sanitary sewers, the following factors should be
considered:
1) Design peak flow.
2) Additional design peak flow from industrial plants.
3) Ground water infiltration.
4) Topography of area.
5) Location of waste treatment plant.
6) Depth of excavation.
7) Pumping requirements.