35 Ill. Adm. Code 370.600
General Considerations
Section 370
Section 370.600 General
Considerations
a) Safety
Safety Features Relative to Location
1) Railings and Gratings
A) Manually cleaned channels shall be protected by guard railings
and deck gratings, with adequate provisions for removal or opening to
facilitate raking.
B) Mechanically cleaned channels shall be protected by guard
railings and deck gratings. Consideration should also be given to temporary
access arrangements to facilitate maintenance and repair.
2) Mechanical Devices
A) Mechanical screening equipment shall have adequate removable
enclosures to protect personnel against accidental contact with moving parts
and to prevent dripping in multi-level installations.
B) A positive means of locking out each mechanical device shall be
provided.
3) Units and Equipment in Deep Pits
Manually cleaned screens located in pits deeper than 4 feet
shall be provided with stairway access, adequate lighting and ventiliation, and
convenient and adequate means for removing screenings. Access ladders may be
used instead of steps in pits less than 4 feet deep. Hoisting or lifting
equipment shall be used where necessitated by the depth of the pit or the
amount of material to be removed.
4) In Buildings
Units and equipment installed in buildings where other
equipment or offices are located shall be isolated from the rest of the
building, and shall be provided with separate outside entrances and separate
and independent means of ventilation.
5) Ventilation
A) Adequate ventilation shall be provided for installations
described in subsections (a)(3) and (4). Ventilation may either be continuous
or intermittent. If continuous, ventilation shall provide at least 12 complete
air changes per hour; if intermittent, ventilation shall provide at least 30
complete air changes per hour.
B) Where the pit is deeper than 4 feet mechanical ventilation is
required, and the air shall be forced into the screen pit area rather than
exhausted from the screen pit. The maximum distance from the fresh air
discharge and the working deck floor shall be 24 inches. Dampers should not be
used on fresh air ducts. Obstructions in air ducts should be avoided to
prevent clogging. Air intake screens (bird and insect) shall be located so as
to be easily accessible for cleaning.
C) Switches for operation of ventilation equipment should be
marked and located at the entrance to the screen pit area. All intermittently
operated ventilating equipment shall be interconnected with the respective
lighting system. Consideration should be given to automatic controls where
intermittent operation is used. The manual lighting-ventilation switch shall
override the automatic controls.
D) The fan wheel shall be fabricated from non-sparking material.
Refer to Section 370.610(a)(3)(C) for motor and electrical requirements.
6) Electrical Fixtures
Electrical fixtures and controls in enclosed places where gas
may accumulate shall comply with Section 370.610(a)(3)(C).
b) Communition
Communition or other in-stream shredding of sewage solids
shall be followed by primary settling or fine screening devices to remove the
shredded stringy materials prior to the activated sludge process to minimize
operational problems associated with reaglomeration of stringy materials.
c) Channels
Channels shall be equipped with the necessary gates to divert
flow from any one unit. Provisions must also be made for dewatering each
unit. Channels preceding and following screens shall be shaped and filleted as
necessary to eliminate settling of solids.