35 Ill. Adm. Code 370.610
Screening Devices
Section 370
Section 370.610 Screening
Devices
a) Bar Racks and Screens
1) Where Required
Screening of raw sewage shall be provided at all mechanical
treatment works. For lift station applications, see Subpart D.
2) Design and Installation
A) Manually Cleaned Screens
Clear openings for manually cleaned screens between bars
should be from 1 to 1 3/4 inches. Design and installation shall be such that
they can be conveniently cleaned. An accessible platform shall be provided on
which the operator may rake screenings easily and safely. Suitable drainage
facilities with return flow to process shall be provided for the platform.
B) Mechanical Screens
Clear openings for mechanically cleaned screens may be as
small as practical to assure the proper operation and maintenance of treatment
facilities. Mechanical screens shall be located so as to be protected from
freezing and to facilitate maintenance.
C) Velocities Through Screens
For manually or mechanically raked bar screens the maximum
velocities during peak flow periods should not exceed 2.5 feet per second. The
velocity shall be calculated from a vertical projection of the screen openings
on the cross-sectional area between the invert of the channel and the flow
line. Excessive head loss through the screen, which may affect upstream flow
measurement or bypassing, shall be taken into account.
D) Invert
The screen channel invert shall be at least 3 inches below
the invert of the incoming sewers. To prevent jetting action, the length
and/or construction of the screen channel shall be adequate to reestablish
hydraulic flow pattern following the drop in elevation.
E) Slope
Manually cleaned screens should be placed on a slope of 30 to
45 degrees with the horizontal.
3) Control Systems
A) Timing Devices
All mechanical units which are operated by timing devices
should be provided with auxiliary controls which will set the cleaning
mechanism in operation at predetermined high water marks.
B) Manual Override
Automatic controls shall be supplemented by a manual
override.
C) Electrical Fixtures and Controls
Electrical fixtures and controls in enclosed places where gas
may accumulate shall comply with the National Electrical Code requirements for
Class I, Group D, Division I locations.
4) Disposal of Screenings
A) Amply-sized, vector-proof facilities shall be provided for
removal, handling and storage of screenings in a sanitary manner. Suitable
drainage facilities shall be provided for the storage areas with drainage
returned to process. The return of ground screenings to the sewage flow is
unacceptable.
B) Disposal shall be in accordance with 35 Ill. Adm. Code 700 and
shall be discussed in the plan documents.
b) Auxiliary Screens
Where mechanically operated screening is used, auxiliary
manually cleaned screens shall be provided. Design shall include provisions
for automatic diversion of the entire sewage flow through the auxiliary screens
should the regular units fail. Refer to subsection (a)(2).
c) Fine Screens
Fine screens may be used in lieu of primary sedimentation
providing that subsequent treatment units are designed on the basis of
anticipated screen performance. Fine screens should not be considered
equivalent to primary sedimentation. Where fine screens are used, additional
removal of floatable oils and greases shall be provided if they will adversely
affect the function of downstream treatment units.