35 Ill. Adm. Code 6110.611.1020
Requirements for Microbial Toolbox Components: Inactivation Toolbox Components
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.1020 REQUIREMENTS FOR MICROBIAL TOOLBOX COMPONENTS: INACTIVATION TOOLBOX COMPONENTS
Section 611.1020 Requirements for Microbial Toolbox
Components: Inactivation Toolbox Components
a) Calculation
of CT Values
1) CT is
the product of the disinfectant contact time (T, in minutes) and disinfectant
concentration (C, in milligrams per liter). A supplier with treatment credit
for chlorine dioxide or ozone under subsection (b) or (c) must calculate CT at
least once each day, with both C and T measured during peak hourly flow, as
specified in Sections 611.531 and 611.532.
2) A
supplier with several disinfection segments in sequence may calculate CT for
each segment, if a disinfection segment is defined as a treatment unit process
with a measurable disinfectant residual level and a liquid volume. Under this
approach, the supplier must add the Cryptosporidium CT values in each segment
to determine the total CT for the treatment plant.
b) CT Values
for Chlorine Dioxide and Ozone
1) A
supplier receives the Cryptosporidium treatment credit listed in Table H by
meeting the corresponding chlorine dioxide CT value for the applicable water
temperature, as described in subsection (a).
2) A
supplier receives the Cryptosporidium treatment credit listed in Table I by
meeting the corresponding ozone CT values for the applicable water temperature,
as described in subsection (a).
c) Site-Specific
Study. The Agency may, by a SEP, approve alternative chlorine dioxide or ozone
CT values to those listed in Tables H and I on a site-specific basis. The
Agency must base this approval on a site-specific study conducted by the
supplier according to an Agency-approved protocol.
d) Ultraviolet
Light. A supplier receives Cryptosporidium, Giardia lamblia, and virus
treatment credits for ultraviolet (UV) light reactors by achieving the
corresponding UV dose values shown in Table J. The supplier must validate and
monitor UV reactors, as described in subsections (d)(2) and (d)(3), to
demonstrate that they are achieving a particular UV dose value for treatment
credit.
1) UV Dose
Table. The treatment credits listed in Table J are for UV light at a
wavelength of 254 nm as produced by a low-pressure mercury vapor lamp. To
receive treatment credit for other lamp types, a supplier must demonstrate an
equivalent germicidal dose through reactor validation testing, as described in
subsection (d)(2). The UV dose values in this table are applicable only to
post-filter applications of UV in a filtered system supplier and to an
unfiltered system supplier.
2) Reactor
Validation Testing. A supplier must use UV reactors that have undergone
validation testing to determine the operating conditions under which the
reactor delivers the UV dose required in subsection (d)(1) (i.e., validated
operating conditions). These operating conditions must include flow rate; UV
intensity, as measured by a UV sensor; and UV lamp status.
A) When
determining validated operating conditions, a supplier must account for the
following factors: UV absorbance of the water; lamp fouling and aging;
measurement uncertainty of on-line sensors; UV dose distributions arising from
the velocity profiles through the reactor; failure of UV lamps or other
critical treatment system components; and inlet and outlet piping or channel
configurations of the UV reactor.
B) Validation
testing must include the following: Full scale testing of a reactor that
conforms uniformly to the UV reactors used by the supplier and inactivation of
a test microorganism whose dose response characteristics have been quantified
with a low pressure mercury vapor lamp.
C) The
Agency may, by a SEP, approve an alternative approach to validation testing.
3) Reactor
Monitoring
A) A
supplier must monitor its UV reactors to determine if the reactors are
operating within validated conditions, as determined under subsection (d)(2).
This monitoring must include UV intensity, as measured by a UV sensor; flow
rate; lamp status; and other parameters that the Agency has designated by a SEP
based on UV reactor operation. A supplier must verify the calibration of UV
sensors and must recalibrate sensors in compliance with a protocol that the
Agency has approved by the SEP.
B) To
receive treatment credit for UV light, a supplier must treat at least 95
percent of the water delivered to the public during each month by UV reactors
operating within validated conditions for the required UV dose, as described in
subsections (d)(1) and (d)(2). The supplier must demonstrate compliance with
this condition by the monitoring required under subsection (d)(3)(A).
BOARD NOTE: Derived from 40 CFR
141.720.