35 Ill. Adm. Code 6110.611.1019
Requirements for Microbial Toolbox Components: Additional Filtration Toolbox Components
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.1019 REQUIREMENTS FOR MICROBIAL TOOLBOX COMPONENTS: ADDITIONAL FILTRATION TOOLBOX COMPONENTS
Section 611.1019 Requirements for Microbial Toolbox
Components: Additional Filtration Toolbox Components
a) Bag
and Cartridge Filters. A supplier receives Cryptosporidium treatment credit of
up to 2.0-log for individual bag or cartridge filters and up to 2.5-log for bag
or cartridge filters operated in series by meeting the criteria in subsections
(a)(1) through (a)(10). To be eligible for this credit, the supplier must
report the results of challenge testing that meets the requirements of
subsections (a)(2) through (a)(9) to the Agency. The filters must treat the
entire plant flow taken from a Subpart B source.
1) The
Cryptosporidium treatment credit awarded to bag or cartridge filters must be
based on the removal efficiency demonstrated during challenge testing that is
conducted according to the criteria in subsections (a)(2) through (a)(9). A
factor of safety equal to 1-log for individual bag or cartridge filters and
0.5-log for bag or cartridge filters in series must be applied to challenge
testing results to determine removal credit. A supplier may use results from
challenge testing conducted prior to January 5, 2006 if the prior testing was
consistent with the criteria specified in subsections (a)(2) through (a)(9).
2) Challenge
testing must be performed on full-scale bag or cartridge filters, and the
associated filter housing or pressure vessel, that are identical in material
and construction to the filters and housings the supplier will use for removal
of Cryptosporidium. Bag or cartridge filters must be challenge tested in the
same configuration that the supplier will use, either as individual filters or
as a series configuration of filters.
3) Challenge
testing must be conducted using Cryptosporidium or a surrogate that is removed
no more efficiently than Cryptosporidium. The microorganism or surrogate used
during challenge testing is referred to as the challenge particulate. The
concentration of the challenge particulate must be determined using a method
capable of discreetly quantifying the specific microorganism or surrogate used
in the test; gross measurements such as turbidity may not be used.
4) The
maximum feed water concentration that can be used during a challenge test must
be based on the detection limit of the challenge particulate in the filtrate
(i.e., filtrate detection limit) and must be calculated using the following
equation:
Maximum
Feed Concentration = 1 x 10
4
x (Filtrate Detection Limit)
5) Challenge
testing must be conducted at the maximum design flow rate for the filter as
specified by the manufacturer.
6) Each
filter evaluated must be tested for a duration sufficient to reach 100 percent
of the terminal pressure drop, which establishes the maximum pressure drop
under which the filter may be used to comply with the requirements of this
Subpart Z.
7) Removal
efficiency of a filter must be determined from the results of the challenge
test and expressed in terms of log removal values using the following equation:
LRV = Log
10
(C
f
) – Log
10
(C
p
)
Where:
LRV
=
log removal value demonstrated
during challenge testing
C
f
=
the feed concentration
measured during the challenge test
C
p
=
the filtrate concentration
measured during the challenge test. In applying this equation, the same
units must be used for the feed and filtrate concentrations. If the challenge
particulate is not detected in the filtrate, then the term C
p
must
be set equal to the detection limit.
8) Each
filter tested must be challenged with the challenge particulate during three
periods over the filtration cycle: within two hours after start-up of a new
filter; when the pressure drop is between 45 and 55 percent of the terminal
pressure drop; and at the end of the cycle after the pressure drop has reached
100 percent of the terminal pressure drop. An LRV must be calculated for each
of these challenge periods for each filter tested. The LRV for the filter (LRV
filter
)
must be assigned the value of the minimum LRV observed during the three
challenge periods for that filter.
9) If
fewer than 20 filters are tested, the overall removal efficiency for the filter
product line must be set equal to the lowest LRV
filter
among the
filters tested. If 20 or more filters are tested, the overall removal
efficiency for the filter product line must be set equal to the 10
th
percentile of the set of LRV
filter
values for the various filters
tested. The percentile is defined by (i/(n+1)) where i is the rank of n
individual data points ordered lowest to highest. If necessary, the 10
th
percentile may be calculated using linear interpolation.
10) If
a previously tested filter is modified in a manner that could change the
removal efficiency of the filter product line, challenge testing to demonstrate
the removal efficiency of the modified filter must be conducted and submitted
in writing to the Agency.
b) Membrane
Filtration
1) A
supplier receives Cryptosporidium treatment credit for membrane filtration that
meets the criteria of this subsection (b). Membrane cartridge filters that
meet the definition of membrane filtration in Section 611.102 are eligible for
this credit. The level of treatment credit a supplier receives is equal to the
lower of the following values:
A) The
removal efficiency demonstrated during challenge testing conducted under the
conditions in subsection (b)(2); or
B) The
maximum removal efficiency that can be verified through direct integrity
testing used with the membrane filtration process under the conditions in
subsection (b)(3).
2) Challenge
Testing. The membrane used by the supplier must undergo challenge testing to
evaluate removal efficiency, and the supplier must report the results of
challenge testing to the Agency. Challenge testing must be conducted according
to the criteria in subsections (b)(2)(A) through (b)(2)(G). A supplier may use
data from challenge testing conducted prior to January 5, 2006 if the prior
testing was consistent with the criteria in subsections (b)(2)(A) through
(b)(2)(G).
A) Challenge
testing must be conducted on either a full-scale membrane module, identical in
material and construction to the membrane modules used in the supplier's
treatment facility, or a smaller-scale membrane module, identical in material
and similar in construction to the full-scale module. A module is defined as
the smallest component of a membrane unit in which a specific membrane surface
area is housed in a device with a filtrate outlet structure.
B) Challenge
testing must be conducted using Cryptosporidium oocysts or a surrogate that is
removed no more efficiently than Cryptosporidium oocysts. The organism or
surrogate used during challenge testing is referred to as the challenge
particulate. The concentration of the challenge particulate, in both the feed
and filtrate water, must be determined using a method capable of discretely
quantifying the specific challenge particulate used in the test; gross
measurements such as turbidity may not be used.
C) The
maximum feed water concentration that can be used during a challenge test is
based on the detection limit of the challenge particulate in the filtrate and
must be determined according to the following equation:
Maximum Feed
Concentration
=
3.16 x 10
6
x (Filtrate Detection Limit)
D) Challenge
testing must be conducted under representative hydraulic conditions at the
maximum design flux and maximum design process recovery specified by the
manufacturer for the membrane module. Flux is defined as the throughput of a pressure
driven membrane process expressed as flow per unit of membrane area. Recovery
is defined as the volumetric percent of feed water that is converted to
filtrate over the course of an operating cycle uninterrupted by events such as
chemical cleaning or a solids removal process (i.e., backwashing).
E) Removal
efficiency of a membrane module must be calculated from the challenge test
results and expressed as a log removal value according to the following
equation:
LRV = Log
10
(C
f
) – Log
10
(C
p
)
Where:
LRV
=
log removal value demonstrated
during the challenge test
C
f
=
the feed concentration measured
during the challenge test
C
p
=
the filtrate concentration
measured during the challenge test. Equivalent units must be used for the
feed and filtrate concentrations. If the challenge particulate is not
detected in the filtrate, the term C
p
is set equal to the
detection limit for the purpose of calculating the LRV. An LRV must be
calculated for each membrane module evaluated during the challenge test.
F) The
removal efficiency of a membrane filtration process demonstrated during
challenge testing must be expressed as a log removal value (LRV
C-Test
).
If fewer than 20 modules are tested, then LRV
C-Test
is equal to the
lowest of the representative LRVs among the modules tested. If 20 or more
modules are tested, then LRV
C-Test
is equal to the 10
th
percentile of the representative LRVs among the modules tested. The percentile
is defined by (i/(n+1)) where i is the rank of n individual data points ordered
lowest to highest. If necessary, the 10
th
percentile may be
calculated using linear interpolation.
G) The
challenge test must establish a quality control release value (QCRV) for a
non-destructive performance test that demonstrates the Cryptosporidium removal
capability of the membrane filtration module. This performance test must be
applied to each production membrane module used by the supplier that was not
directly challenge tested in order to verify Cryptosporidium removal
capability. Production modules that do not meet the established QCRV are not
eligible for the treatment credit demonstrated during the challenge test.
H) If a
previously tested membrane is modified in a manner that could change the
removal efficiency of the membrane or the applicability of the non-destructive
performance test and associated QCRV, additional challenge testing to
demonstrate the removal efficiency of, and determine a new QCRV for, the
modified membrane must be conducted and submitted to the Agency.
3) Direct
Integrity Testing. A supplier must conduct direct integrity testing in a
manner that demonstrates a removal efficiency equal to or greater than the
removal credit awarded to the membrane filtration process and meets the
requirements described in subsections (b)(3)(A) through (b)(3)(F). A
"direct integrity test" is defined as a physical test applied to a membrane
unit in order to identify and isolate integrity breaches (i.e., one or more
leaks that could result in contamination of the filtrate).
A) The
direct integrity test must be independently applied to each membrane unit in
service. A membrane unit is defined as a group of membrane modules that share
common valving that allows the unit to be isolated from the rest of the
treatment system for the purpose of integrity testing or other maintenance.
B) The
direct integrity method must have a resolution of three micrometers or less, if
resolution is defined as the size of the smallest integrity breach that
contributes to a response from the direct integrity test.
C) The
direct integrity test must have a sensitivity sufficient to verify the log
treatment credit awarded to the membrane filtration process by the Agency, if
sensitivity is defined as the maximum log removal value that can be reliably
verified by a direct integrity test. Sensitivity must be determined using the
appropriate of the following approaches, considering the type of direct
integrity test the supplier uses:
i) For
a direct integrity test that uses an applied pressure or vacuum, the direct
integrity test sensitivity must be calculated according to the following
equation:
Where:
LRV
DIT
=
the sensitivity of the direct
integrity test
Q
p
=
total design filtrate flow from
the membrane unit
Q
breach
=
flow of water from an integrity
breach associated with the smallest integrity test response that can be reliably
measured
VCF
=
volumetric concentration
factor. The volumetric concentration factor is the ratio of the suspended
solids concentration on the high pressure side of the membrane relative to
that in the feed water; or
ii) For
a direct integrity test that uses a particulate or molecular marker, the direct
integrity test sensitivity must be calculated according to the following
equation:
LRV
DIT
= Log
10
(C
f
) - Log
10
(C
p
)
Where:
LRV
DIT
=
the sensitivity of the direct integrity test
C
f
=
the typical feed concentration of the marker used in the
test
C
p
=
the filtrate concentration of the marker from an integral
membrane unit
D) A
supplier must establish a control limit within the sensitivity limits of the
direct integrity test that is indicative of an integral membrane unit capable
of meeting the removal credit awarded by the Agency.
E) If the
result of a direct integrity test exceeds the control limit established under
subsection (b)(3)(D), the supplier must remove the membrane unit from service.
The supplier must conduct a direct integrity test to verify any repairs, and it
may return the membrane unit to service only if the direct integrity test is
within the established control limit.
F) A
supplier must conduct direct integrity testing on each membrane unit at a
frequency of not less than once each day that the membrane unit is in
operation. The Agency may, by a SEP, approve less frequent testing, based on
demonstrated process reliability, the use of multiple barriers effective for
Cryptosporidium, or reliable process safeguards.
4) Indirect
Integrity Monitoring. A supplier must conduct continuous indirect integrity
monitoring on each membrane unit according to the criteria in subsections
(b)(4)(A) through (b)(4)(E). "Indirect integrity monitoring" is
defined as monitoring some aspect of filtrate water quality that is indicative
of the removal of particulate matter. A supplier that implements continuous
direct integrity testing of membrane units in compliance with the criteria in
subsections (b)(3)(A) through (b)(3)(E) is not subject to the requirements for
continuous indirect integrity monitoring. The supplier must submit a monthly
report to the Agency summarizing all continuous indirect integrity monitoring
results triggering direct integrity testing and the corrective action that was
taken in each case.
A) Unless
the Agency approves an alternative parameter by a SEP, continuous indirect
integrity monitoring must include continuous filtrate turbidity monitoring.
B) Continuous
indirect integrity monitoring must be conducted at a frequency of no less than
once every 15 minutes.
C) Continuous
indirect integrity monitoring must be separately conducted on each membrane
unit.
D) If
continuous indirect integrity monitoring includes turbidity and if the filtrate
turbidity readings are above 0.15 NTU for a period greater than 15 minutes
(i.e., two consecutive 15-minute readings above 0.15 NTU), direct integrity
testing must immediately be performed on the associated membrane unit, as
specified in subsections (b)(3)(A) through (b)(3)(E).
E) If
indirect integrity monitoring includes an Agency-approved alternative parameter
and if the alternative parameter exceeds an Agency-approved control limit for a
period greater than 15 minutes, direct integrity testing must immediately be
performed on the associated membrane units, as specified in subsections
(b)(3)(A) through (b)(3)(E).
c) Second
Stage Filtration. A supplier receives 0.5-log Cryptosporidium treatment credit
for a separate second stage of filtration that consists of sand, dual media,
GAC, or other fine grain media following granular media filtration if the
Agency approves by a SEP. To be eligible for this credit, the first stage of
filtration must be preceded by a coagulation step and both filtration stages
must treat the entire plant flow taken from a surface water or groundwater
under the direct influence of surface water source. A cap, such as GAC, on a
single stage of filtration is not eligible for this credit. The Agency must
approve the treatment credit based on an assessment of the design
characteristics of the filtration process.
d) Slow Sand
Filtration (as secondary filter). A supplier is eligible to receive 2.5-log
Cryptosporidium treatment credit by a SEP for a slow sand filtration process
that follows a separate stage of filtration if both filtration stages treat
entire plant flow taken from a surface water or groundwater under the direct
influence of surface water source and no disinfectant residual is present in
the influent water to the slow sand filtration process. The Agency must
approve the treatment credit based on an assessment of the design
characteristics of the filtration process. This subsection (d) does not apply
to treatment credit awarded to slow sand filtration used as a primary
filtration process.
BOARD NOTE: Derived from 40 CFR
141.719.