35 Ill. Adm. Code 604.405
Forced or Induced Draft Aeration
Section 604.405 Forced or Induced Draft Aeration
Forced or induced draft aeration devices must be designed
to:
a) include
a blower with a weatherproof motor in a tight housing and screened enclosure;
b) insure
adequate counter current of air through the enclosed aerator column;
c) exhaust air directly to
the outside atmosphere;
d) include a down turned
and 24 mesh screened air outlet and inlet;
e) be
such that air introduced in the column must be as free from obnoxious fumes,
dust, and dirt as possible;
f) be
such that sections of the aerator can be reached or removed for maintenance of
the interior or installed in a separate aerator room;
g) provide
loading at a rate of 1 to 5 gallons per minute for each square foot of total
tray area (2.5 to 12.5 m/hr);
h) ensure
that the water outlet is sealed;
i) discharge
through a series of five or more trays with separation of trays not less than six
inches;
j) provide distribution of
water uniformly over the top tray; and
k) be of
durable material resistant to the aggressiveness of the water and dissolved
gases.