35 Ill. Adm. Code 6110.611.381
Analytical Requirements
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.381 ANALYTICAL REQUIREMENTS
Section 611.381
Analytical Requirements
a)
A supplier
must
use only the
analytical methods this Section specifies, each incorporated by reference in
Section 611.102,
or alternative methods that the Agency approved under
Section 611.480
to demonstrate that it
complies with this Subpart
I and Subparts W and Y
.
b) Disinfection Byproducts (DBPs)
1)
Methods for
Disinfection Byproducts
(DBPs)
A) TTHM
i) By Purge
and Trap, Gas Chromatography, Electrolytic Conductivity Detector, and Photoionization
Detector. USEPA 502.2 (95). If TTHMs are the only analytes the laboratory
measures in the sample, it needs not use a photoionization detector.
ii) By Purge
and Trap, Gas Chromatography-Mass Spectrometer. USEPA 524.2 (95) or USEPA
524.3 (09), or USEPA 524.4 (13).
iii) By Liquid-Liquid
Extraction, Gas Chromatography, Electron Capture Detector. USEPA 551.1 (95).
B) HAA5
i) Liquid-Liquid
Extraction (Diazomethane), Gas Chromatography, Electron Capture Detector. SM
6251 B (94) or SM 6251 B (07).
ii) Solid
Phase Extractor (Acidic Methanol), Gas Chromatography, Electron Capture
Detector. USEPA 552.1 (92).
iii) Liquid-Liquid
Extraction (Acidic Methanol), Gas Chromatography, Electron Capture Detector.
USEPA 552.2 (95) or 552.3 (03).
iv) Ion
Chromatography, Electrospray Ionization, Tandem Mass Spectrometry. USEPA 557
(09).
v)
Two-Dimensional
Ion Chromatography (IC) with Suppressed Conductivity Detection. Thermo-Fisher
557.1 (17).
C) Bromate
i) Ion
Chromatography. ASTM D6581-00 or USEPA 300.1 (97).
ii) Ion
Chromatography and Post-Column Reaction. USEPA 317.0 (01) or USEPA 326.0 (02).
iii) Inductively
Coupled Plasma-Mass Spectrometer. USEPA 321.8 (97).
iv) Two-Dimensional
Ion Chromatography. USEPA 302.0 (09).
v) Ion
Chromatography, Electrospray Ionization, Tandem Mass Spectrometry. USEPA 557
(09).
vi) Chemically
Suppressed Chromatography. ASTM D6581-08 A.
vii) Electrolytically
Suppressed Chromatography. ASTM D6581-08 B.
BOARD NOTE: The supplier must use
ion chromatography and post column reaction or inductively coupled plasma-mass
spectrometry to monitor bromate to demonstrate eligibility for reduced
monitoring under Section 611.382(b)(3)(B). For inductively coupled plasma-mass
spectrometry, the supplier must preserve samples at the time of sampling with
50 mg ethylenediamine (EDA) per liter of sample, and the supplier must analyze the
samples within 28 days.
D) Chlorite
i) Amperometric
Titration for Daily Monitoring Under Section 611.382(b)(2)(A)(i). SM 4500-ClO
2
E (93) or 4500-ClO
2
E (00).
ii) Amperometric
Sensor for Daily Monitoring Under Section 611.382(b)(2)(A)(i). Palintest ChlordioX
Plus (13) or Palintest ChlordioX Plus (20).
iii) Spectrophotometry.
USEPA 327.0 (05).
iv) Ion
Chromatography. USEPA 300.0 (09), USEPA 300.1 (97), USEPA 317.0 (01), USEPA
326.0 (02), or ASTM D6581-00.
v) Chemically
Suppressed Chromatography. ASTM D6581-08 A.
vi) Electrolytically
Suppressed Chromatography. ASTM D6581-08 B.
BOARD NOTE: The supplier may use
amperometric titration or spectrophotometry for routine daily monitoring of
chlorite at the entrance to the distribution system under Section
611.382(b)(2)(A)(i). The supplier must use ion chromatography for routine
monthly chlorite monitoring and additional chlorite monitoring in the
distribution system, as Section 611.382(b)(2)(A)(ii) and (b)(2)(B) require.
2) Only a certified laboratory in one of
the categories in Section 611.490(a) may conduct analyses for
DBPs under
this Section except as subsection (b)(3) specifies otherwise
. To receive certification to conduct analyses
for the DBP contaminants in Sections 611.312 and 611.381 and Subparts W and Y,
the laboratory must fulfill the specific conditions in subsections (b)(2)(A),
(b)(2)(C), and (b)(2)(D).
A) The
laboratory must analyze performance evaluation (PE) samples acceptable to the
Agency at least once during each consecutive 12-month period by each method for
which the laboratory seeks certification.
B) This
subsection corresponds with 40 CFR 141.131(b)(2)(ii), which has expired by its
own terms. This statement maintains structural consistency with the
corresponding federal rule.
C) The
laboratory must achieve quantitative results on the PE sample analyses within
the acceptance limits in subsections (b)(2)(C)(i) through (b)(2)(B)(xi),
subject to subsections (b)(2)(C)(xii) and (b)(2)(C)(xiii):
i) Chloroform
(a THM): ± 20% of true value;
ii) Bromodichloromethane
a THM): ± 20% of true value;
iii) Dibromochloromethane
(a THM): ± 20% of true value;
iv) Bromoform
(a THM): ± 20% of true value;
v) Monochloroacetic
Acid (an HAA5): ± 40% of true value;
vi) Dichloroacetic
Acid (an HAA5): ± 40% of true value;
vii) Trichloroacetic
Acid (an HAA5): ± 40% of true value;
viii) Monobromoacetic
Acid (an HAA5): ± 40% of true value;
ix) Dibromoacetic
Acid (an HAA5): ± 40% of true value;
x) Chlorite:
± 30% of true value; and
xi) Bromate:
± 30% of true value.
xii) The
laboratory must meet all four of the individual THM acceptance limits in subsections
(b)(2)(B)(i) through (b)(2)(B)(iv) to successfully pass a PE sample for TTHM.
xiii) The
laboratory must meet the acceptance limits for four out of the five HAA5
compounds in subsections (b)(2)(B)(v) through (b)(2)(B)(ix) to successfully
pass a PE sample for HAA5.
D) The
laboratory must report quantitative data for concentrations at least as low as
the minimum reporting levels (MRLs) in subsections (b)(2)(D)(i) through
(b)(2)(D)(xi), subject to subsections (b)(2)(D)(xii) and (b)(2)(D)(xiii), for
all DBP samples it analyzes to comply with Sections 611.312 and 611.385 and
Subparts W and Y:
i) Chloroform
(a THM): 0.0010 mg/L;
ii) Bromodichloromethane
(a THM): 0.0010 mg/L;
iii) Dibromochloromethane
(a THM): 0.0010 mg/L;
iv) Bromoform
(a THM): 0.0010 mg/L;
v) Monochloroacetic
Acid (an HAA5): 0.0020 mg/L;
vi) Dichloroacetic
Acid (an HAA5): 0.0010 mg/L;
vii) Trichloroacetic
Acid (an HAA5): 0.0010 mg/L;
viii) Monobromoacetic
Acid (an HAA5): 0.0010 mg/L;
ix) Dibromoacetic
Acid (an HAA5): 0.0010 mg/L;
x) Chlorite:
0.020 mg/L, applicable to monitoring as required by Section
611.382(b)(2)(A)(ii) and (b)(2)(B); and
xi) Bromate:
0.0050, or 0.0010 mg/L if the laboratory uses USEPA 317.0 (01), USEPA 321.8 (97),
or USEPA 326.0 (02).
xii) The
calibration curve must encompass the regulatory MRL concentration. The
laboratory may report data for concentrations lower than the regulatory MRL if
the laboratory meets the precision and accuracy criteria by analyzing an MRL
check standard at the lowest reporting limit the laboratory chooses. The
laboratory must verify the accuracy of the calibration curve at the MRL
concentration by analyzing an MRL check standard with a concentration less than
or equal to 110% of the MRL with each batch of samples. The measured
concentration for the MRL check standard must be ±50% of the expected value if
any field sample in the batch has a concentration less than five times the
regulatory MRL. The laboratory must analyze higher concentration check
standards and meet tighter acceptance criteria in addition to the MRL check
standard.
xiii) When
adding the individual trihalomethane or haloacetic acid concentrations for the
compounds listed in subsections (b)(2)(D)(v) through (b)(2)(D)(ix) to calculate
the TTHM or HAA5 concentrations, a zero is used for any analytical result that
is less than the MRL concentration for that DBP, unless the Agency specifies otherwise.
3) A
party must measure daily chlorite samples at the entrance to the distribution
system as the Agency requires.
c) Disinfectant
Residuals
1)
A supplier
must
measure
residual disinfectant concentrations for free chlorine, combined chlorine
(chloramines), and chlorine dioxide using the methods in subsections (c)(1)(A)
through (c)(1)(D), subject to subsection (c)(1)(E):
A) Free
Chlorine
i) Amperometric
Titration. ASTM D1253-86, ASTM D1253-96, ASTM D1253-03, ASTM D1253-08, ASTM
D1253-14, SM 4500-Cl D (93), or SM 4500- Cl D (00).
ii) DPD Ferrous
Titration. SM 4500-Cl F (93) or SM 4500-Cl F (00).
iii) DPD Colorimetric.
Hach 10260 (13), SM 4500-Cl G (93), or SM 4500-Cl G (00).
iv) Syringaldazine
(FACTS). SM 4500-Cl H (93) or SM 4500-Cl H (00).
v)
Test Strips. ITS D99-003 (03)
if approved by the Agency under subsection (c)(2).
vi) Amperometric
Sensor. Palintest ChloroSense (09) or Palintest ChloroSense (20).
vii) On-Line
Chlorine Analyzer. USEPA 334.0 (09).
viii) Indenophenol Colorimetric. Hach 10241 (15).
B) Combined
Chlorine
i) Amperometric
Titration. ASTM D1253-86, ASTM D1253-96, ASTM D1253-03, ASTM D1253-08, or ASTM
D1253-14, SM 4500-Cl D (93), or SM 4500-CL D (00).
ii) DPD Ferrous
Titration. SM 4500-Cl F (93) or SM 4500-Cl F (00).
iii) DPD Colorimetric.
Hach 10260 (13), SM 4500-Cl G (93), or SM 4500-Cl G (00).
C) Total
Chlorine
i) Amperometric
Titration. ASTM D1253-86, ASTM D1253-96, ASTM D1253-03, ASTM D1253-08, or ASTM
D1253-14, SM 4500-Cl D (93), or SM 4500-Cl D (00).
ii) Low-Level
Amperometric Titration. SM 4500-Cl E (93) or SM 4500-Cl E (00).
iii) DPD Ferrous
Titration. SM 4500-Cl F (93) or SM 4500-Cl F (00).
iv) DPD Colorimetric.
Hach 10260 (13), SM 4500-Cl G (93), or SM 4500-Cl G (00).
v) Iodometric
Electrode. SM 4500-Cl I (93) or SM 4500-Cl I (00).
vi) Amperometric
Sensor. Palintest ChloroSense (09) or Palintest ChloroSense (20).
vii) On-Line
Chlorine Analyzer. USEPA 334.0 (09).
D) Chlorine
Dioxide
i) DPD.
SM 4500-ClO
2
D (93) or SM 4500-ClO
2
D (00).
ii) Amperometric
Method II. SM 4500-ClO
2
E (93) or SM 4500-ClO
2
E (00).
iii) Amperometric
Sensor. Palintest ChlordioX Plus (13) or Palintest ChlordioX Plus (20).
iv) Lissamine
Green Spectrophotometric. USEPA 327.0 (05).
E) USEPA
approved these methods for measuring the specified disinfectant residual. The
supplier may measure free chlorine or total chlorine for the chlorine MRDL and
combined chlorine. The supplier may measure total chlorine for the chloramine
MRDL.
2) Alternative Methods Available Only upon
Specific Agency Approval
A) Test Strips.
ITS Method D99-003 (03).
BOARD NOTE: USEPA added ITS
Method D99-003 (03) as an approved alternative method, contingent upon specific
State approval. The Agency may issue a SEP approving this method on a
case-by-case basis.
B) If the Agency approves in a SEP, a
supplier may also measure residual disinfectant concentrations for chlorine,
chloramines, and chlorine dioxide using DPD colorimetric test kits.
3) An Agency-approved party
must
measure residual disinfectant concentration.
d)
A supplier that must
analyze
parameters not included in subsections (b) and (c)
must
use the methods in this subsection (d). An
Agency-approved party
must
measure certain
parameters
:
1) Alkalinity. All methods in Section
611.611(a)(21) for alkalinity.
2) Bromide. Ion Chromatography.
ASTM D6581-00, USEPA 300.0 (93), USEPA 300.1 (97), USEPA
317.0 (01), or USEPA 326.0 (02)
.
3) Total Organic Carbon (TOC), by any of
the methods in subsection (d)(3)(A), subject to subsection (d)(3)(B).
A) Analytical
Methods
i) High-Temperature
Combustion. SM 5310 B (92), SM 5310 B (96), SM 5310 B (00), SM 5310 B (14), SM
5310 B (22), USEPA 415.3 (05), or USEPA 415.3 (09).
ii) Persulfate-Ultraviolet
or Heated-Persulfate Oxidation. Hach 10267 (15), SM 5310 C (92), SM 5310 C
(96), SM 5310 C (00), SM 5310 C (14), USEPA 415.3 (05), or USEPA 415.3 (09).
iii) Wet Oxidation
Method. SM 5310 D (92), SM 5310 D (96), SM 5310 D (00), SM 5310 D (14), USEPA
415.3 (05), or USEPA 415.3 (09).
iv) Ozone
Oxidation. Hach 10261 (15).
B) The
supplier must remove inorganic carbon from the samples prior to analysis. The
supplier and supplier must not filter TOC samples prior to analysis. The
supplier must acidify TOC samples at the time of sample collection to achieve
pH less than or equal to 2 with minimal addition of the acid the method specifies
or instrument manufacturer recommends. The supplier must analyze acidified TOC
samples within 28 days.
4) Specific Ultraviolet Absorbance (SUVA). SUVA is equal to the UV absorption at 254 nm (UV
254
) (measured in m
-
1
)
divided
by the dissolved organic carbon
(DOC) concentration (measured as mg/
L
).
To determine SUVA, the supplier must separately measure UV
254
and
DOC. When determining SUVA, a supplier must use the methods in subsection
(d)(4)(
A
) for DOC and the method in
subsection (d)(4)(
B
) for UV
254
.
The supplier must determine SUVA on water prior to the supplier adding
disinfectants or oxidants. The supplier must take DOC and UV
254
samples for a SUVA value at the same time and at the same location.
A) Dissolved Organic Carbon (DOC). Prior
to analysis, the supplier must filter DOC samples through the 0.45
m
m pore-diameter filter
as soon as practical after sampling, not
to exceed 48 hours. After
filtration
,
the supplier must acidify DOC samples to achieve pH less than or equal to 2
with minimal addition of the acid the method or instrument manufacturer specifies.
The supplier must analyze acidified DOC samples within 28 days after sample
collection. The supplier must remove inorganic carbon from the samples prior
to analysis. The supplier must use water
passed
through the filter as the filtered blank. The supplier must analyze this filtered
blank using procedures identical to those it used for analysis of the samples,
and the blank must less than 0.5 mg/
L DOC.
i) High-Temperature
Combustion Method. SM 5310 B (92), SM 5310 B (96), SM 5310 B (00), SM 5310 B
(14), SM 5310 B (22) USEPA 415.3 (05), or USEPA 415.3 (09).
ii) Persulfate-Ultraviolet
or Heated-Persulfate Oxidation Method. SM 5310 C (92), SM 5310 C (96), SM 5310
C (00), SM 5310 C (14), USEPA 415.3 (05), or USEPA 415.3 (09).
iii) Wet-Oxidation
Method. SM 5310 D (92), (96), SM 5310 D (00), USEPA 415.3 (05), or USEPA 415.3
(09).
B) Ultraviolet Absorption at 254 nm (UV
254
)
by Spectrometry. SM 5910 B
(94), SM 5910 B (00), 5910 B (11), 5910 B
(13),
USEPA 415.3 (05), or USEPA 415.3 (09).
The supplier must measure UV absorption at 253.7 nm (may be rounded off to 254
nm). Prior to analysis, the supplier must filter UV
254
samples
through a 0.45
m
m pore-diameter filter. The supplier must not
adjust pH of UV
254
samples. The supplier must analyze samples as
soon as practical after sampling, not to exceed 48 hours.
5) pH. All methods in Section
611.611(a)(17) for pH.
6) Magnesium.
All methods in Section 611.611(a) for magnesium.
BOARD NOTE: This Section derives from
40 CFR 141.131 and appendix A to 40 CFR 141. The Board did not separately list
approved alternative methods from Standard Methods Online that are the same
version as a method appearing in a printed edition of Standard Methods. Using the
Standard Methods Online copy is acceptable.
Standard Methods Online, Methods
4500‑Cl D-93, 4500‑Cl E-93, 4500‑Cl F-93, 4500‑Cl G-93,
4500‑Cl H-93, and 4500‑Cl I-93 appear in the 19
th
and 20
th
editions as Methods 4500‑Cl D, 4500‑Cl E, 4500‑Cl F, 4500‑Cl
G, 4500‑Cl H, and 4500‑Cl I. These appear in this Section as SM
4500‑Cl D (93), SM 4500‑Cl E (93), SM 4500‑Cl F (93), SM 4500‑Cl
G (93), SM 4500‑Cl H (93), and SM 4500‑Cl I (93).
Standard Methods Online, Methods
4500‑Cl D-00, 4500‑Cl E-00, 4500‑Cl F-00, 4500‑Cl G-00,
4500‑Cl H-00, and 4500‑Cl I-00 appear in the 21
st
, 22
nd
,
and 23
rd
editions as Methods 4500‑Cl D, 4500‑Cl E, 4500‑Cl
F, 4500‑Cl G, 4500‑Cl H, and 4500‑Cl I. These appear in this
Section as SM 4500‑Cl D (00), 4500‑Cl E (00), 4500‑Cl F (00),
4500‑Cl G (00), 4500‑Cl H (00), and 4500‑Cl I (00).
Standard Methods Online, Methods
4500‑ClO
2
D-93 and 4500‑ClO
2
E-93 appear in
the 19
th
and 20
th
editions as Methods 4500‑ClO
2
D and 4500‑ClO
2
E. These appear in this Section as SM 4500‑ClO
2
D (93) and SM 4500‑ClO
2
E (93).
Standard Methods Online, Methods
4500‑ClO
2
D-00 and 4500‑ClO
2
E-00 appear in
the 21
st
, 22
nd
, and 23
rd
editions as Methods
4500‑ClO
2
D and 4500‑ClO2 E. These appear in this
Section as SM 4500‑ClO
2
D (00) and SM 4500‑ClO2 E (00).
Standard
Methods Online, Methods 5310 B-00, 5310 C-00, and 5310 D-00
appear in the
21
st
and 22
nd
editions as Methods 5310 B, 5310 C, and
5310 D. These appear in this Section as SM 5310 B (00), SM 5310 C (00), and SM
5310 D (00).
Standard
Methods Online, Method 5910 B-00
appears in the 21
st
edition as
Method 5910 B. This appears in this Section as SM 5910 B (00).
Standard
Methods Online, Method 5910 B-11
appears in the 22
nd
edition as
Method 5910 B. This appears in this Section as SM 5910 B (11).
Standard Methods Online, Method
6251 B-94 appears in the 19
th
, 20
th
, and 21
st
editions as Method 6251 B. This appears in this Section as SM 6251 B (94).
Standard Methods Online, Method
6251 B-07 appears in the 22
nd
and 23
rd
editions as Method
5910 B. This appears in this Section as SM 6251 B (07).