35 Ill. Adm. Code 721.935
Recordkeeping Requirements
Section 721.935 Recordkeeping Requirements
a) Compliance Required
1) Each
remanufacturer or other person that stores or treats the hazardous secondary
material subject to the provisions of this Subpart AA must comply with the recordkeeping
requirements of this Section.
2) A
remanufacturer or other person that stores or treats the hazardous secondary
material of more than one hazardous secondary material management unit subject
to the provisions of this Subpart AA may comply with the recordkeeping
requirements for these hazardous secondary material management units in one
recordkeeping system if the system identifies each record by each hazardous
secondary material management unit.
b) The
remanufacturer or other person that stores or treats the hazardous secondary
material must keep the following records on-site:
1) For
facilities that comply with the provisions of Section 721.933(a)(2), an
implementation schedule that includes dates by which the closed-vent system and
control device will be installed and in operation. The schedule must also
include a rationale of why the installation cannot be completed at an earlier
date. The implementation schedule must be kept on-site at the facility by the
effective date that the facility becomes subject to the provisions of this
Subpart AA.
2) Up-to-date
documentation of compliance with the process vent standards in Section 721.932,
including the following:
A) Information
and data identifying all affected process vents, annual throughput and
operating hours of each affected unit, estimated emission rates for each
affected vent and for the overall facility (i.e., the total emissions for all
affected vents at the facility), and the approximate location within the
facility of each affected unit (e.g., identify the hazardous secondary material
management units on a facility plot plan).
B) Information
and data supporting determinations of vent emissions and emission reductions
achieved by add-on control devices based on engineering calculations or source
tests. For the purpose of determining compliance, determinations of vent
emissions and emission reductions must be made using operating parameter values
(e.g., temperatures, flow rates, or vent stream organic compounds and
concentrations) that represent the conditions that result in maximum organic
emissions, such as when the hazardous secondary material management unit is
operating at the highest load or capacity level reasonably expected to occur.
If the remanufacturer or other person that stores or treats the hazardous
secondary material takes any action (e.g., managing a material of different
composition or increasing operating hours of affected hazardous secondary
material management units) that would result in an increase in total organic
emissions from affected process vents at the facility, then a new determination
is required.
3) Where
a remanufacturer or other person that stores or treats the hazardous secondary
material chooses to use test data to determine the organic removal efficiency
or total organic compound concentration achieved by the control device, a
performance test plan must be developed and include the following:
A) A
description of how it is determined that the planned test is going to be
conducted when the hazardous secondary material management unit is operating at
the highest load or capacity level reasonably expected to occur. This must
include the estimated or design flow rate and organic content of each vent
stream and define the acceptable operating ranges of key process and control
device parameters during the test program.
B) A
detailed engineering description of the closed-vent system and control device,
including the following:
i) Manufacturer's name
and model number of control device.
ii) Type of control
device.
iii) Dimensions of the
control device.
iv) Capacity.
v) Construction materials.
C) A
detailed description of sampling and monitoring procedures, including sampling
and monitoring locations in the system, the equipment to be used, sampling and
monitoring frequency, and planned analytical procedures for sample analysis.
4) Documentation
of compliance with Section 721.933 must include the following information:
A) A list
of all information references and sources used in preparing the documentation.
B) Records,
including the dates, of each compliance test required by Section 721.933(k).
C) If
engineering calculations are used, a design analysis, specifications, drawings,
schematics, and piping and instrumentation diagrams based on the appropriate
sections of "APTI Course 415: Control of Gaseous Emissions",
incorporated by reference as specified in 35 Ill. Adm. Code 720.111, or other
engineering texts acceptable to the Agency that present basic control device
design information. Documentation provided by the control device manufacturer
or vendor that describes the control device design in accordance with
subsections (b)(4)(C)(i) through (b)(4)(C)(vii) may be used to comply with this
requirement. The design analysis must address the vent stream characteristics
and control device operation parameters, as specified below. The Agency must
state whether or not the other engineering texts are acceptable or unacceptable
in writing to the remanufacturer or other person that stores or treats the hazardous
secondary material.
i) For
a thermal vapor incinerator, the design analysis must consider the vent stream
composition, constituent concentrations, and flow rate. The design analysis
must also establish the design minimum and average temperature in the
combustion zone and the combustion zone residence time.
ii) For
a catalytic vapor incinerator, the design analysis must consider the vent
stream composition, constituent concentrations, and flow rate. The design
analysis must also establish the design minimum and average temperatures across
the catalyst bed inlet and outlet.
iii) For
a boiler or process heater, the design analysis must consider the vent stream
composition, constituent concentrations, and flow rate. The design analysis
must also establish the design minimum and average flame zone temperatures,
combustion zone residence time, and description of method and location where
the vent stream is introduced into the combustion zone.
iv) For a
flare, the design analysis must consider the vent stream composition,
constituent concentrations, and flow rate. The design analysis must also
consider the requirements specified in Section 721.933(d).
v) For a
condenser, the design analysis must consider the vent stream composition, constituent
concentrations, flow rate, relative humidity, and temperature. The design
analysis must also establish the design outlet organic compound concentration
level, design average temperature of the condenser exhaust vent stream, and
design average temperatures of the coolant fluid at the condenser inlet and
outlet.
vi) For a
carbon adsorption system such as a fixed-bed adsorber that regenerates the
carbon bed directly onsite in the control device, the design analysis must
consider the vent stream composition, constituent concentrations, flow rate,
relative humidity, and temperature. The design analysis must also establish
the design exhaust vent stream organic compound concentration level, number and
capacity of carbon beds, type and working capacity of activated carbon used for
carbon beds, design total steam flow over the period of each complete carbon
bed regeneration cycle, duration of the carbon bed steaming and cooling/ drying
cycles, design carbon bed temperature after regeneration, design carbon bed
regeneration time, and design service life of carbon.
vii) For a
carbon adsorption system such as a carbon canister that does not regenerate the
carbon bed directly onsite in the control device, the design analysis must
consider the vent stream composition, constituent concentrations, flow rate,
relative humidity, and temperature. The design analysis must also establish
the design outlet organic concentration level, capacity of carbon bed, type and
working capacity of activated carbon used for carbon bed, and design carbon
replacement interval based on the total carbon working capacity of the control
device and source operating schedule.
D) A
statement signed and dated by the remanufacturer or other person that stores or
treats the hazardous secondary material certifying that the operating
parameters used in the design analysis reasonably represent the conditions that
exist when the hazardous secondary material management unit is or would be
operating at the highest load or capacity level reasonably expected to occur.
E) A
statement signed and dated by the remanufacturer or other person that stores or
treats the hazardous secondary material certifying that the control device is
designed to operate at an efficiency of 95 percent or greater unless the total
organic concentration limit of Section 721.932(a) is achieved at an efficiency
less than 95 weight percent or the total organic emission limits of Section
721.932(a) for affected process vents at the facility can be attained by a
control device involving vapor recovery at an efficiency less than 95 weight
percent. A statement provided by the control device manufacturer or vendor
certifying that the control equipment meets the design specifications may be
used to comply with this requirement.
F) If performance
tests are used to demonstrate compliance, all test results.
c) Design
documentation and monitoring, operating, and inspection information for each
closed-vent system and control device required to comply with the provisions of
this part must be recorded and kept up-to-date at the facility. The
information must include the following:
1) Description
and date of each modification that is made to the closed-vent system or control
device design.
2) Identification
of operating parameter, description of monitoring device, and diagram of
monitoring sensor location or locations used to comply with Section 721.933
(f)(1) and (f)(2).
3) Monitoring,
operating, and inspection information required by Section 721.933(f) through
(k).
4) Date,
time, and duration of each period that occurs while the control device is
operating when any monitored parameter exceeds the value established in the
control device design analysis, as specified below:
A) For a
thermal vapor incinerator designed to operate with a minimum residence time of
0.50 second at a minimum temperature of 760 °C, period when the combustion
temperature is below 760 °C.
B) For a
thermal vapor incinerator designed to operate with an organic emission
reduction efficiency of 95 weight percent or greater, period when the
combustion zone temperature is more than 28 °C below the design average
combustion zone temperature established as a requirement of subsection
(b)(4)(C)(i).
C) For a
catalytic vapor incinerator, period when either of the following occurs:
i) Temperature
of the vent stream at the catalyst bed inlet is more than 28 °C below the
average temperature of the inlet vent stream established as a requirement of
subsection (b)(4)(C)(ii); or
ii) Temperature
difference across the catalyst bed is less than 80 percent of the design
average temperature difference established as a requirement of subsection
(b)(4)(C)(ii).
D) For a
boiler or process heater, period when either of the following occurs:
i) Flame
zone temperature is more than 28 °C below the design average flame zone
temperature established as a requirement of subsection (b)(4)(C)(iii); or
ii) Position
changes where the vent stream is introduced to the combustion zone from the
location established as a requirement of subsection (b)(4)(C)(iii).
E) For a flare, period when
the pilot flame is not ignited.
F) For a
condenser that complies with Section 721.933(f)(2)(F)(i), period when the
organic compound concentration level or readings of organic compounds in the exhaust
vent stream from the condenser are more than 20 percent greater than the design
outlet organic compound concentration level established as a requirement of
subsection (b)(4)(C)(v).
G) For a
condenser that complies with Section 721.933(f)(2)(F)(ii), period when either
of the following occurs:
i) Temperature
of the exhaust vent stream from the condenser is more than 6 °C above the
design average exhaust vent stream temperature established as a requirement of
subsection (b)(4)(C)(v); or
ii) Temperature
of the coolant fluid exiting the condenser is more than 6 °C above the design
average coolant fluid temperature at the condenser outlet established as a
requirement of subsection (b)(4)(C)(v).
H) For a
carbon adsorption system, such as a fixed-bed carbon adsorber that regenerates
the carbon bed directly onsite in the control device and which complies with
Section 721.933(f)(2)(G)(i), any period when the organic compound concentration
level or readings of organic compounds in the exhaust vent stream from the
carbon bed are more than 20 percent greater than the design exhaust vent stream
organic compound concentration level established as a requirement of subsection
(b)(4)(C)(vi).
I) For a
carbon adsorption system, such as a fixed-bed carbon adsorber that regenerates
the carbon bed directly onsite in the control device and which complies with
Section 721.933(f)(2)(G)(ii), any period when the vent stream continues to flow
through the control device beyond the predetermined carbon bed regeneration
time established as a requirement of subsection (b)(4)(C)(vi).
5) Explanation
for each period recorded under subsection (c)(4) of the cause for control
device operating parameter exceeding the design value and the measures
implemented to correct the control device operation.
6) For a
carbon adsorption system operated subject to requirements specified in Section
721.933(g) or (h)(2), any date when existing carbon in the control device is
replaced with fresh carbon.
7) For a
carbon adsorption system operated subject to requirements specified in Section
721.933(h)(1), a log that records:
A) Date
and time when control device is monitored for carbon breakthrough and the
monitoring device reading.
B) Date
when existing carbon in the control device is replaced with fresh carbon.
8) Date of each control
device startup and shutdown.
9) A
remanufacturer or other person that stores or treats the hazardous secondary
material designating any components of a closed-vent system as unsafe to
monitor pursuant to Section 721.933(o) must record in a log that is kept at the
facility the identification of closed-vent system components that are
designated as unsafe to monitor in accordance with the requirements of Section
721.933(o), an explanation for each closed-vent system component stating why
the closed-vent system component is unsafe to monitor, and the plan for
monitoring each closed-vent system component.
10) When
each leak is detected as specified in Section 721.933(l), the following
information must be recorded:
A) The instrument
identification number, the closed-vent system component identification number,
and the operator name, initials, or identification number.
B) The
date the leak was detected and the date of first attempt to repair the leak.
C) The date of successful
repair of the leak.
D) Maximum
instrument reading measured by Reference Method 21 (Determination of Volatile
Organic Compound Leaks) in appendix A to 40 CFR 60 (Test Methods), incorporated
by reference in 35 Ill. Adm. Code 720.111, after it is successfully repaired or
determined to be nonrepairable.
E) "Repair
delayed" and the reason for the delay if a leak is not repaired within 15
calendar days after discovery of the leak.
i) The
remanufacturer or other person that stores or treats the hazardous secondary
material may develop a written procedure that identifies the conditions that
justify a delay of repair. In such cases, reasons for delay of repair may be
documented by citing the relevant sections of the written procedure.
ii) If
delay of repair was caused by depletion of stocked parts, there must be
documentation that the spare parts were sufficiently stocked on-site before
depletion and the reason for depletion.
d) Records
of the monitoring, operating, and inspection information required by
subsections (c)(3) through (c)(10) must be maintained by the owner or operator
for at least three years following the date of each occurrence, measurement,
maintenance, corrective action, or record.
e) For a
control device other than a thermal vapor incinerator, catalytic vapor
incinerator, flare, boiler, process heater, condenser, or carbon adsorption
system, the Agency must specify the appropriate recordkeeping requirements.
The Agency must specify the appropriate recordkeeping requirements in writing
to the remanufacturer or other person that stores or treats the hazardous
secondary material.
f) Up-to-date
information and data used to determine whether or not a process vent is subject
to the requirements in Section 721.932, including supporting documentation as
required by Section 721.934(d)(2) when application of the knowledge of the
nature of the hazardous secondary material stream or the process by which it
was produced is used, must be recorded in a log that is kept at the facility.