35 Ill. Adm. Code 721.934
Test Methods and Procedures
Section 721.934 Test Methods and Procedures
a) Each
remanufacturer or other person that stores or treats the hazardous secondary
material subject to the provisions of this Subpart AA must comply with the test
methods and procedural requirements provided in this Section.
b) When
a closed-vent system is tested for compliance with no detectable emissions, as
required in Section 721.933(l) of this Subpart AA, the test must comply with
the following requirements:
1) Monitoring
must comply with Reference Method 21 (Determination of Volatile Organic
Compound Leaks) in appendix A to 40 CFR 60 (Test Methods), incorporated by
reference in 35 Ill. Adm. Code 720.111.
2) The
detection instrument must meet the performance criteria of Reference Method 21.
3) The
instrument must be calibrated before use on each day of its use by the
procedures specified in Reference Method 21.
4) Calibration
gases must be:
A) Zero air (less than 10
ppm of hydrocarbon in air).
B) A
mixture of methane or n-hexane and air at a concentration of approximately, but
less than, 10,000 ppm methane or n-hexane.
5) The
background level must be determined as set forth in Reference Method 21.
6) The
instrument probe must be traversed around all potential leak interfaces as
close to the interface as possible as described in Reference Method 21.
7) The
arithmetic difference between the maximum concentration indicated by the
instrument and the background level is compared with 500 ppm for determining
compliance.
c) Performance
tests to determine compliance with Section 721.932(a) and with the total
organic compound concentration limit of Section 721.933(c) must comply with the
following:
1) Performance
tests to determine total organic compound concentrations and mass flow rates
entering and exiting control devices must be conducted and data reduced in
accordance with the following reference methods and calculation procedures:
A) Reference
Method 2 (Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S
Pitot Tube)) in appendix A to 40 CFR 60 (Test Methods), incorporated by
reference in 35 Ill. Adm. Code 720.111 for velocity and volumetric flow rate.
B) Reference
Method 18 (Measurement of Gaseous Organic Compound Emissions by Gas
Chromatography) or Reference Method 25A (Determination of Total Gaseous Organic
Concentration Using a Flame Ionization Analyzer) in appendix A to 40 CFR 60
(Test Methods), incorporated by reference in 35 Ill. Adm. Code 720.111, for
organic content. If Reference Method 25A is used, the organic HAP used as the
calibration gas must be the single organic HAP representing the largest percent
by volume of the emissions. The use of Reference Method 25A is acceptable if
the response from the high-level calibration gas is at least 20 times the
standard deviation of the response from the zero calibration gas when the
instrument is zeroed on the most sensitive scale.
C) Each
performance test must consist of three separate runs; each run must be conducted
for at least one hour under the conditions that exist when the hazardous
secondary material management unit is operating at the highest load or capacity
level reasonably expected to occur. For the purpose of determining total
organic compound concentrations and mass flow rates, the average of results of
all runs must apply. The average must be computed on a time-weighted basis.
D) Total
organic mass flow rates must be determined by the following equation:
i) For sources utilizing
Reference Method 18.
Where:
E
h
=
Total organic mass flow rate,
kg/h
Q
2sd
=
Volumetric
flow rate of gases entering or exiting control device, as determined by
Reference Method 2, dscm/h
n
=
Number of organic compounds in
the vent gas
C
i
=
Organic concentration in ppm,
dry basis, of compound i in the vent gas, as determined by Reference Method
18
MW
i
=
Molecular
weight of organic compound i in the vent gas, kg/kg-mol
0.0416
=
Conversion factor for molar
volume, kg-mol/m
3
(@293 K and 760 mm Hg)
10
-6
=
Conversion from ppm
ii) For
sources utilizing Reference Method 25A.
E
h
=
(Q)(C)(MW)(0.0416)(10
-6
)
Where:
E
h
=
Total organic mass flow rate,
kg/h
Q
=
Volumetric
flow rate of gases entering or exiting control device, as determined by
Reference Method 2, dscm/h
C
=
Organic concentration in ppm,
dry basis, as determined by Reference Method 25A
MW
=
Molecular weight of propane,
44
0.0416
=
Conversion factor for molar
volume, kg-mol/m
3
(@293 K and 760 mm Hg)
10
-6
=
Conversion from ppm
E) The
annual total organic emission rate must be determined by the following
equation:
E
A
=(E
h
)(H)
Where:
E
A
=
Total organic mass emission
rate, kg/y
E
h
=
Total organic
mass flow rate for the process vent, kg/h
H
=
Total annual hours of
operations for the affected unit, h/y
F) Total
organic emissions from all affected process vents at the facility must be
determined by summing the hourly total organic mass emission rates (E
h
,
as determined in subsection (c)(1)(D)) and by summing the annual total organic
mass emission rates (E
A
, as determined in subsection (c)(1)(E)) for
all affected process vents at the facility.
2) The
remanufacturer or other person that stores or treats the hazardous secondary
material must record process information as necessary to determine the
conditions of the performance tests. Operations during periods of startup,
shutdown, and malfunction must not constitute representative conditions for the
purpose of a performance test.
3) The
remanufacturer or other person that stores or treats the hazardous secondary
material at an affected facility must provide, or cause to be provided,
performance testing facilities, as follows:
A) Sampling
ports adequate for the test methods specified in subsection (c)(1).
B) Safe sampling platforms.
C) Safe access to sampling
platforms.
D) Utilities for sampling
and testing equipment.
4) For
the purpose of making compliance determinations, the time-weighted average of
the results of the three runs must apply. In the event that a sample is
accidentally lost or conditions occur in which one of the three runs must be
discontinued because of forced shutdown, failure of an irreplaceable portion of
the sample train, extreme meteorological conditions, or other circumstances
beyond the control of the remanufacturer or other person that stores or treats
the hazardous secondary material, the Agency may approve compliance
determination using the average of the results of the two other runs. The
Agency must state any approval or disapproval of a compliance determination in
writing to the remanufacturer or other person that stores or treats the
hazardous secondary material.
d) To
show that a process vent associated with a hazardous secondary material
distillation, fractionation, thin-film evaporation, solvent extraction, or air
or steam stripping operation is not subject to the requirements of this Subpart
AA, the remanufacturer or other person that stores or treats the hazardous
secondary material must make an initial determination that the time-weighted,
annual average total organic concentration of the material managed by the
hazardous secondary material management unit is less than 10 ppmw using one of
the following two methods:
1) Direct
measurement of the organic concentration of the material using the following
procedures:
A) The
remanufacturer or other person that stores or treats the hazardous secondary
material must take a minimum of four grab samples of material for each material
stream managed in the affected unit under process conditions expected to cause
the maximum material organic concentration.
B) For
material generated onsite, the grab samples must be collected at a point before
the material is exposed to the atmosphere such as in an enclosed pipe or other closed
system that is used to transfer the material after generation to the first
affected distillation, fractionation, thin-film evaporation, solvent
extraction, or air or steam stripping operation. For material generated
offsite, the grab samples must be collected at the inlet to the first material
management unit that receives the material provided the material has been
transferred to the facility in a closed system such as a tank truck and the
material is not diluted or mixed with other material.
C) Each
sample must be analyzed and the total organic concentration of the sample must
be computed using Method 9060A of "Test Methods for Evaluating Solid
Waste, Physical/Chemical Methods", EPA Publication SW-846, incorporated by
reference in 35 Ill. Adm. Code 720.111, or analyzed for its individual organic
constituents.
D) The
arithmetic mean of the results of the analyses of the four samples must apply
for each material stream managed in the unit in determining the time-weighted,
annual average total organic concentration of the material. The time-weighted
average is to be calculated using the annual quantity of each material stream
processed and the mean organic concentration of each material stream managed in
the unit.
2) Using
knowledge of the material to determine that its total organic concentration is
less than 10 ppmw. Documentation of the material determination is required.
Examples of documentation that must be used to support a determination under
this provision include production process information documenting that no
organic compounds are used, information that the material is generated by a
process that is identical to a process at the same or another facility that has
previously been demonstrated by direct measurement to generate a material stream
having a total organic content less than 10 ppmw, or prior speciation analysis
results on the same material stream where it can also be documented that no
process changes have occurred since that analysis that could affect the
material total organic concentration.
e) The
determination that distillation, fractionation, thin-film evaporation, solvent
extraction, or air or steam stripping operations manage hazardous secondary
materials with time-weighted, annual average total organic concentrations less
than 10 ppmw must be made as follows:
1) By
the effective date that the facility becomes subject to the provisions of this
Subpart AA or by the date when the material is first managed in a hazardous
secondary material management unit, whichever is later; and
2) For continuously
generated material, annually; or
3) Whenever
there is a change in the material being managed or a change in the process that
generates or treats the material.
f) When
a remanufacturer or other person that stores or treats the hazardous secondary
material and the Agency do not agree on whether a distillation, fractionation,
thin-film evaporation, solvent extraction, or air or steam stripping operation
manages a hazardous secondary material with organic concentrations of at least 10
ppmw based on knowledge of the material, the dispute may be resolved by using
direct measurement, as specified at subsection (d)(1). The Agency must state
any disagreement in writing to the remanufacturer or other person that stores
or treats the hazardous secondary material.