35 Ill. Adm. Code 721.983
Material Determination Procedures
Section 721.983 Material Determination Procedures
a) Procedure
to Determine Average Volatile Organic (VO) Concentration
1) Determining
average VO concentration at the point of material origination. A
remanufacturer or other person that stores or treats the hazardous secondary
material must determine the average VO concentration at the point of material
origination for each hazardous secondary material placed in a hazardous
secondary material management unit exempted under the provisions of Section
721.982(c) from using air emission controls in compliance with standards
specified in Sections 721.984 through 721.987, as applicable to the hazardous
secondary material management unit.
A) An
initial determination of the average VO concentration of the material stream
must be made before the first time any portion of the material in the hazardous
secondary material stream is placed in a hazardous secondary material
management unit exempted under the provisions of Section 721.982(c) from using
air emission controls, and thereafter an initial determination of the average
VO concentration of the material stream must be made for each averaging period
that a hazardous secondary material is managed in the unit; and
B) Perform
a new material determination whenever changes to the source generating the
material stream are reasonably likely to cause the average VO concentration of
the hazardous secondary material to increase to a level that is equal to or
greater than the applicable VO concentration limits specified in Section
721.982.
2) Determining
average VO concentration using direct measurement or knowledge. For a material
determination that is required by subsection (a)(1), the average VO
concentration of a hazardous secondary material at the point of material
origination must be determined using either direct measurement, as specified in
subsection (a)(3), or by knowledge of the hazardous secondary material, as
specified in subsection (a)(4).
3) Direct
measurement to determine average VO concentration of a hazardous secondary
material at the point of material origination, as follows:
A) Identification.
The remanufacturer or other person that stores or treats the hazardous
secondary material must identify and record in a log that is kept at the
facility the point of material origination for the hazardous secondary
material.
B) Sampling.
Samples of the hazardous secondary material stream must be collected at the
point of material origination in a manner so that volatilization of organics
contained in the material and in the subsequent sample is minimized and an
adequately representative sample is collected and maintained for analysis by
the selected method.
i) The
averaging period to be used for determining the average VO concentration for
the hazardous secondary material stream on a mass-weighted average basis must
be designated and recorded. The averaging period can represent any time
interval that the remanufacturer or other person that stores or treats the
hazardous secondary material determines is appropriate for the hazardous
secondary material stream but must not exceed one year.
ii) Enough
samples, but at least four, must be collected and analyzed for a hazardous
secondary material determination. The samples for a given material
determination must be collected within a one-hour period. The average of the
four or more sample results constitutes a material determination for the material
stream. One or more material determinations may be required to represent the
complete range of material compositions and quantities that occur during the
entire averaging period due to normal variations in the operating conditions
for the source or process generating the hazardous secondary material stream.
Examples of these normal variations are seasonal variations in material
quantity or fluctuations in ambient temperature.
iii) All
samples must be collected and handled according to written procedures prepared
by the remanufacturer or other person that stores or treats the hazardous
secondary material and documented in a site sampling plan. This plan must
describe the procedure by which representative samples of the hazardous
secondary material stream are collected so that a minimum loss of organics
occurs throughout the sample collection and handling process, and by which
sample integrity is maintained. A copy of the written sampling plan must be
maintained at the facility. An example of acceptable sample collection and
handling procedures for a total volatile organic constituent concentration may
be found in Reference Method 25D (Determination of the Volatile Organic
Concentration of Waste Samples) in appendix A to 40 CFR 60 (Test Methods),
incorporated by reference in 35 Ill. Adm. Code 720.111.
iv) Sufficient
information, as specified in the "site sampling plan" required under
subsection (a)(3)(B)(iii), must be prepared and recorded to document the
material quantity represented by the samples and, as applicable, the operating
conditions for the source or process generating the hazardous secondary
material represented by the samples.
C) Analysis.
Each collected sample must be prepared and analyzed according to Reference
Method 25D (Determination of the Volatile Organic Concentration of Waste
Samples) in appendix A to 40 CFR 60 (Test Methods), incorporated by reference
in 35 Ill. Adm. Code 720.111, for the total concentration of volatile organic
constituents, or using one or more methods when the individual organic compound
concentrations are identified and summed and the summed material concentration
accounts for and reflects all organic compounds in the material with Henry's
law constant values at least 0.1
mole-fraction-in-the-gas-phase/mole-fraction-in-the-liquid-phase (0.1 Y/X) (which
can also be expressed as 1.8 × 10
-6
atmospheres/gram-mole/m
3
)
at 25 ºC. At the discretion of the remanufacturer or other person that stores
or treats the hazardous secondary material, the test data obtained may be
adjusted by any appropriate method to discount any contribution to the total
volatile organic concentration that is a result of including a compound with a
Henry's law constant value of less than 0.1 Y/X at 25 °C. To adjust these
data, the measured concentration of each individual chemical constituent
contained in the material is multiplied by the appropriate constituent-specific
adjustment factor (fm
25D
). If the remanufacturer or other person
that stores or treats the hazardous secondary material elects to adjust the
test data, the adjustment must be made to all individual chemical constituents
with a Henry's law constant value greater than or equal to 0.1 Y/X at 25 ºC
contained in the material. To adjust these data, the measured concentration of
each individual chemical constituent contained in the waste is multiplied by
the constituent-specific adjustment factors (fm
25D
) approved in
writing by the Agency. Other test methods may be used if they meet the
requirements in subsection (a)(3)(C)(i) or (a)(3)(C)(ii) and provided the
requirement to reflect all organic compounds in the material with Henry's law
constant values greater than or equal to 0.1 Y/X (which can also be expressed
as 1.8 × 10
-6
atmospheres/gram-mole/m
3
) at 25 ºC, is met.
i) Any
USEPA standard method that has been validated in compliance with appendix D to
40 CFR 63 (Alternative Validation Procedure for EPA Waste and Wastewater
Methods), incorporated by reference in 35 Ill. Adm. Code 720.111.
ii) Any
other analysis method that has been validated in according to the procedures
specified in Section 5.1 or Section 5.3, and the corresponding calculations in
Section 6.1 or Section 6.3, of Method 301 (Field Validation of Pollutant
Measurement Methods from Various Waste Media) in appendix A to 40 CFR 63 (Test
Methods), incorporated by reference in 35 Ill. Adm. Code 720.111. The data are
acceptable if they meet the criteria specified in Section 6.1.5 or Section
6.3.3 of Method 301. If correction is required under section 6.3.3 of Method
301, the data are acceptable if the correction factor is within the range 0.7
to 1.30. Other sections of Method 301 are not required.
D) Calculations
i) The
average VO concentration (
)
on a mass-weighted basis must be calculated by using the results for all
material determinations conducted in compliance with subsections (a)(3)(B) and
(a)(3)(C) and the following equation:
Where:
=
Average VO
concentration of the hazardous secondary material at the point of material
origination on a mass-weighted basis, ppmw
i
=
Individual
material determination "i" of the hazardous secondary material
n
=
Total number
of material determinations of the hazardous secondary material conducted for
the averaging period (not to exceed one year)
Q
i
=
Mass quantity
of hazardous secondary material stream represented by C
i
, kg/hr
Q
T
=
Total mass
quantity of hazardous secondary material during the averaging period, kg/hr
C
i
=
Measured VO
concentration of material determination "i" as determined in compliance
with subsection (a)(3)(C) (i.e., the average of the four or more samples
specified in subsection (a)(3)(B)(ii)), ppmw
ii) For
determining C
i
, for individual material samples analyzed in compliance
with subsection (a)(3)(C), the remanufacturer or other person that stores or
treats the hazardous secondary material must account for VO concentrations
determined to be below the detection limit of the analytical method by using
the VO concentration that is one-half the blank value determined in the method
at section 4.4 of Reference Method 25D, if Reference Method 25D is used for the
analysis; or that is one-half the sum of the limits of detection established
for each organic constituent in the material that has a Henry's law constant
values at least 0.1
mole-fraction-in-the-gas-phase/mole-fraction-in-the-liquid-phase (0.1 Y/X) (which
can also be expressed as 1.8 × 10
‑6
atmospheres/gram-mole/m
3
)
at 25 °C, if any other analytical method is used.
4) Use
of knowledge by the remanufacturer or other person that stores or treats the
hazardous secondary material to determine average VO concentration of a
hazardous secondary material at the point of material origination.
A) Documentation
must be prepared that presents the information used as the basis for the
knowledge by the remanufacturer or other person that stores or treats the
hazardous secondary material of the hazardous secondary material stream's
average VO concentration. Examples of information that may be used as the
basis for knowledge include material balances for the source or process
generating the hazardous secondary material stream; constituent-specific
chemical test data for the hazardous secondary material stream from previous
testing that are still applicable to the current material stream; previous test
data for other locations managing the same type of material stream; or other
knowledge based on information included in shipping papers or material
certification notices.
B) If
test data are used as the basis for knowledge, then the remanufacturer or other
person that stores or treats the hazardous secondary material must document the
test method, sampling protocol, and the means by which sampling variability and
analytical variability are accounted for in determining the average VO
concentration. For example, a remanufacturer or other person that stores or
treats the hazardous secondary material may use organic concentration test data
for the hazardous secondary material stream that are validated according to
Method 301 (Field Validation of Pollutant Measurement Methods from Various
Waste Media) in appendix A to 40 CFR 63 (Test Methods) as the basis for
knowledge of the material.
C) A
remanufacturer or other person that stores or treats the hazardous secondary
material using chemical constituent-specific concentration test data as the
basis for knowledge of the hazardous secondary material may adjust the test
data to the corresponding average VO concentration value that would have been
obtained had the material samples been analyzed using Reference Method 25D
(Determination of the Volatile Organic Concentration of Waste Samples) in
appendix A to 40 CFR 60 (Test Methods), incorporated by reference in 35 Ill.
Adm. Code 720.111(b). To adjust these data, the measured concentration for
each individual chemical constituent contained in the material is multiplied by
the appropriate constituent-specific adjustment factor (fm
25D
).
D) In the
event that the Agency and the remanufacture or other person that stores or
treats the hazardous secondary material disagree on a determination of the
average VO concentration for a hazardous secondary material stream using
knowledge, then the results from a determination of average VO concentration
using direct measurement, as specified in subsection (a)(3), must be used to
establish compliance with the applicable requirements of this Subpart CC. The
Agency may perform or request that the remanufacturer or other person that
stores or treats the hazardous secondary material perform this determination
using direct measurement. The remanufacturer or other person that stores or
treats the hazardous secondary material may choose one or more appropriate
methods to analyze each collected sample under subsection (a)(3)(C). The
Agency must state any disagreement on determination of the average VO
concentration for a hazardous secondary material stream using knowledge in
writing to the remanufacturer or other person that stores or treats the
hazardous secondary material.
b) This
subsection (b) corresponds with 40 CFR 261.1083(b), marked "reserved"
by USEPA. This statement maintains structural consistency with the federal
regulations.
c) Procedure
to Determine the Maximum Organic Vapor Pressure of a Hazardous Secondary Material
in a Tank
1) A
remanufacturer or other person that stores or treats the hazardous secondary
material must determine the maximum organic vapor pressure for each hazardous
secondary material placed in a tank using Tank Level 1 controls in compliance
with standards specified in Section 721.984(c).
2) A
remanufacturer or other person that stores or treats the hazardous secondary
material must use either direct measurement as specified in subsection (c)(3)
or knowledge of the waste as specified by subsection (c)(4) to determine the
maximum organic vapor pressure that is representative of the hazardous
secondary material composition stored or treated in the tank.
3) Direct
Measurement to Determine the Maximum Organic Vapor Pressure of a Hazardous
Secondary Material
A) Sampling.
Enough samples must be collected to be representative of the hazardous
secondary material contained in the tank. All samples must be collected and
handled according to written procedures prepared by the remanufacturer or other
person that stores or treats the hazardous secondary material and documented in
a site sampling plan. This plan must describe the procedure by which
representative samples of the hazardous secondary material are collected so
that a minimum loss of organics occurs throughout the sample collection and
handling process and by which sample integrity is maintained. A copy of the
written sampling plan must be maintained at the facility. An example of
acceptable sample collection and handling procedures may be found in Reference
Method 25D (Determination of the Volatile Organic Concentration of Waste
Samples) in appendix A to 40 CFR 60 (Test Methods), incorporated by reference
in 35 Ill. Adm. Code 720.111(b).
B) Analysis.
Any appropriate one of the following methods may be used to analyze the samples
and compute the maximum organic vapor pressure of the hazardous secondary
material:
i) Reference
Method 25E (Determination of Vapor Phase Organic Concentration in Waste
Samples) in appendix A to 40 CFR 60 (Test Methods), incorporated by reference
in 35 Ill. Adm. Code 720.111(b);
ii) Methods
described in American Petroleum Institute Publication 2517, Third Edition,
February 1989, "Evaporative Loss from External Floating-Roof Tanks",
incorporated by reference in 35 Ill. Adm. Code 720.111;
iii) Methods obtained from
standard reference texts;
iv) ASTM
Method 2879-92, incorporated by reference in 35 Ill. Adm. Code 720.111; and
v) Any other method
approved in writing by the Agency.
4) Use
of Knowledge to Determine the Maximum Organic Vapor Pressure of the Hazardous Secondary
Material. Documentation must be prepared and recorded that presents the
information used as the basis for the knowledge by the remanufacturer or other
person that stores or treats the hazardous secondary material that the maximum
organic vapor pressure of the hazardous secondary material is less than the
maximum vapor pressure limit listed in Section 721.984(b)(1)(A) for the
applicable tank design capacity category. An example of information that may
be used is documentation that the hazardous secondary material is generated by
a process for which at other locations it previously has been determined by
direct measurement that the hazardous secondary material's waste maximum
organic vapor pressure is less than the maximum vapor pressure limit for the
appropriate tank design capacity category.
d) Procedure
for Determining No Detectable Organic Emissions for the Purpose of Complying
with this Subpart CC
1) The
test must be conducted according to the procedures specified in Reference
Method 21 (Determination of Volatile Organic Compound Leaks) in appendix A to
40 CFR 60 (Test Methods), incorporated by reference in 35 Ill. Adm. Code
720.111. Each potential leak interface (i.e., a location if organic vapor
leakage could occur) on the cover and associated closure devices must be
checked. Potential leak interfaces that are associated with covers and closure
devices include the interface of the cover and its foundation mounting, the
periphery of any opening on the cover and its associated closure device, and
the sealing seat interface on a spring-loaded pressure relief valve.
2) The
test must be performed when the unit contains a hazardous secondary material
having an organic concentration representative of the range of concentrations
for the hazardous secondary material expected to be managed in the unit.
During the test, the cover and closure devices must be secured in the closed
position.
3) The
detection instrument must meet the performance criteria of Reference Method 21,
except the instrument response factor criteria in section 3.1.2(a) of Reference
Method 21, must be for the average composition of the organic constituents in
the hazardous secondary material placed in the hazardous secondary management
unit, not for each individual organic constituent.
4) The
detection instrument must be calibrated before use on each day of its use by
the procedures specified in Reference Method 21.
5) Calibration gases must
be as follows:
A) Zero air (less than 10
ppmv hydrocarbon in air); and
B) A
mixture of methane or n-hexane and air at a concentration of approximately, but
less than, 10,000 ppmv methane or n-hexane.
6) The
background level must be determined according to the procedures in Reference
Method 21.
7) Each
potential leak interface must be checked by traversing the instrument probe
around the potential leak interface as close to the interface as possible, as
described in Reference Method 21. If the configuration of the cover or closure
device prevents a complete traverse of the interface, all accessible portions
of the interface must be sampled. If the configuration of the closure device
prevents any sampling at the interface and the device is equipped with an
enclosed extension or horn (e.g., some pressure relief devices), the instrument
probe inlet must be placed at approximately the center of the exhaust area to
the atmosphere.
8) The
arithmetic difference between the maximum organic concentration indicated by
the instrument and the background level must be compared with the value of 500
ppmv except when monitoring a seal around a rotating shaft that passes through
a cover opening, in which case the comparison must be as specified in
subsection (d)(9). If the difference is less than 500 ppmv, then the potential
leak interface is determined to operate with no detectable organic emissions.
9) For
the seals around a rotating shaft that passes through a cover opening, the
arithmetic difference between the maximum organic concentration indicated by
the instrument and the background level must be compared with the value of
10,000 ppmw. If the difference is less than 10,000 ppmw, then the potential
leak interface is determined to operate with no detectable organic emissions.