35 Ill. Adm. Code 724.326
Monitoring and Inspection
Section 724
Section 724.326Â Monitoring
and Inspection
a)Â Â Â Â Â Â Â Â During construction and installation, liners (except in the
case of existing portions of surface impoundments exempt from Section
724.321(a)) and cover systems (e.g., membranes, sheets, or coatings) must be
inspected for uniformity, damage and imperfections (e.g., holes, cracks, thin
spots, or foreign materials). Immediately after construction or installation:
1)Â Â Â Â Â Â Â Â Synthetic liners and covers must be inspected to ensure tight
seams and joints and the absence of tears, punctures, and blisters; and
2)Â Â Â Â Â Â Â Â Soil-based and admixed liners and covers must be inspected for
imperfections including lenses, cracks, channels, root holes, or other
structural non-uniformities that may cause an increase in the permeability of
that liner or cover.
b)Â Â Â Â Â Â Â Â While a surface impoundment is in operation, it must be
inspected weekly and after storms to detect evidence of any of the following:
1)Â Â Â Â Â Â Â Â Deterioration, malfunctions, or improper operation of
overtopping control systems;
2)Â Â Â Â Â Â Â Â Sudden drops in the level of the impoundment's contents; and
3)Â Â Â Â Â Â Â Â Severe erosion or other signs of deterioration in dikes or
other containment devices.
c)Â Â Â Â Â Â Â Â Prior to the issuance of a permit, and after any extended
period of time (more than six months) during which the impoundment was not in
service, the owner or operator must obtain a certification from a qualified
engineer that the impoundment's dike, including that portion of any dike that provides
freeboard, has structural integrity. The certification must establish, in
particular, that the following are true of the dike:
1)Â Â Â Â Â Â Â Â It will withstand the stress of the pressure exerted by the
types and amounts of wastes to be placed in the impoundment; and
2)Â Â Â Â Â Â Â Â It will not fail due to scouring or piping, without dependence
on any liner system included in the surface impoundment construction.
d)Â Â Â Â Â Â Â Â Monitoring of LDS.
1)Â Â Â Â Â Â Â Â An owner or operator required to have a LDS under Section
724.321(c) or (d) must record the amount of liquids removed from each LDS sump
at least once each week during the active life and closure period.
2)Â Â Â Â Â Â Â Â After the final cover is installed, the amount of liquids
removed from each LDS sump must be recorded at least monthly. If the liquid
level in the sump stays below the pump operating level for two consecutive
months, the amount of liquids in the sumps must be recorded at least
quarterly. If the liquid level in the sump stays below the pump operating
level for two consecutive quarters, the amount of liquids in the sumps must be
recorded at least semi-annually. If at any time during the post-closure care
period the pump operating level is exceeded at units on quarterly or
semi-annual recording schedules, the owner or operator must return to monthly
recording of amounts of liquids removed from each sump until the liquid level
again stays below the pump operating level for two consecutive months.
3)Â Â Â Â Â Â Â Â "Pump operating level" is a liquid level proposed by
the owner or operator pursuant to 35 Ill. Adm. Code 703.203(b)(5) and approved
by the Agency based on pump activation level, sump dimensions, and level that
avoids backup into the drainage layer and minimizes head in the sump.