35 Ill. Adm. Code 724.327
Emergency Repairs; Contingency Plans
Section 724
Section 724.327 Emergency
Repairs; Contingency Plans
a) A surface impoundment must be removed from service in
accordance with subsection (b) when either of the following occurs:
1) The level of liquids in the impoundment suddenly drops and the
drop is not known to be caused by changes in the flows into or out of the
impoundment; or
2) The dike leaks.
b) When a surface impoundment must be removed from service as
required by subsection (a), the owner or operator must do the following:
1) Immediately shut off the flow or stop the addition of wastes
into the impoundment;
2) Immediately contain any surface leakage that has occurred or
is occurring;
3) Immediately stop the leak;
4) Take any other necessary steps to stop or prevent catastrophic
failure;
5) If a leak cannot be stopped by any other means, empty the
impoundment; and
6) Notify the Agency of the problem in writing within seven days
after detecting the problem.
c) As part of the contingency plan required in Subpart D, the
owner or operator must specify a procedure for complying with the requirements
of subsection (b).
d) No surface impoundment that has been removed from service in
accordance with the requirements of this section may be restored to service
unless the portion of the impoundment that was failing is repaired and the
following steps are taken:
1) If the impoundment was removed from service as the result of
actual or imminent dike failure, the dike's structural integrity must be re-certified
in accordance with Section 724.326(c).
2) If the impoundment was removed from service as the result of a
sudden drop in the liquid level, then the following apply:
A) For any existing portion of the impoundment, a liner must be
installed in compliance with Section 724.321(a) or 724.322; and
B) For any other portion of the impoundment, the repaired liner
system must be certified by a qualified engineer as meeting the design
specifications approved in the permit.
e) A surface impoundment that has been removed from service in
accordance with the requirements of this Section and that is not being repaired
must be closed in accordance with the provisions of Section 724.328.