35 Ill. Adm. Code 725.190
Applicability
Section 725
Section 725.190Â
Applicability
a)Â Â Â Â Â Â Â Â The owner or operator of a surface impoundment, landfill, or
land treatment facility that is used to manage hazardous waste must implement a
groundwater monitoring program capable of determining the facility's impact on
the quality of groundwater in the uppermost aquifer underlying the facility,
except as Section 725.101 and subsection (c) provide otherwise.
b)Â Â Â Â Â Â Â Â Except as subsections (c) and (d) provide otherwise, the owner
or operator must install, operate, and maintain a groundwater monitoring system
that meets the requirements of Section 725.191 and must comply with Sections
725.192 through 725.194. This groundwater monitoring program must be carried
out during the active life of the facility and for disposal facilities during
the post-closure care period as well.
c)Â Â Â Â Â Â Â Â All or part of the groundwater monitoring requirements of this
Subpart F may be waived if the owner or operator can demonstrate that there is
a low potential for migration of hazardous waste or hazardous waste
constituents from the facility via the uppermost aquifer to water supply wells
(domestic, industrial, or agricultural) or to surface water. This demonstration
must be in writing and must be kept at the facility. This demonstration must be
certified by a qualified geologist or geotechnical engineer and must establish
the following:
1)Â Â Â Â Â Â Â Â The potential for migration of hazardous waste or hazardous
waste constituents from the facility to the uppermost aquifer by an evaluation
of the following information:
A)Â Â Â Â Â Â Â A water balance of precipitation, evapotranspiration, run-off,
and infiltration; and
B)Â Â Â Â Â Â Â Unsaturated zone characteristics (i.e., geologic materials,
physical properties, and depth to ground water); and
2)Â Â Â Â Â Â Â Â The potential for hazardous waste or hazardous waste
constituents that enter the uppermost aquifer to migrate to a water supply well
or surface water by an evaluation of the following information:
A)Â Â Â Â Â Â Â Saturated zone characteristics (i.e., geologic materials,
physical properties, and rate of groundwater flow); and
B)Â Â Â Â Â Â Â The proximity of the facility to water supply wells or surface
water.
d)Â Â Â Â Â Â Â Â If an owner or operator assumes (or knows) that groundwater
monitoring of indicator parameters in accordance with Sections 725.191 and
725.192 would show statistically significant increases (or decreases in the
case of pH) when evaluated pursuant to Section 725.193(b), it may install,
operate, and maintain an alternate groundwater monitoring system (other than
the one described in Sections 725.191 and 725.192). If the owner or operator
decides to use an alternate groundwater monitoring system, it must have done as
follows:
1)Â Â Â Â Â Â Â Â The owner or operator must develop a specific plan, certified
by a qualified geologist or geotechnical engineer, that satisfies the
requirements of federal 40 CFR 265.93(d)(3) for an alternate groundwater
monitoring system. This plan is to be placed in the facility's operating
record and maintained until closure of the facility;
2)Â Â Â Â Â Â Â Â The owner or operator must have initiated the determinations
specified in federal 40 CFR 265.93(d)(4);
3)Â Â Â Â Â Â Â Â The owner or operator must prepare a written report in
accordance with Section 725.193(d)(5) and place it in the facility's operating
record and maintain until closure of the facility;
4)Â Â Â Â Â Â Â Â The owner or operator must continue to make the determinations
specified in Section 725.193(d)(4) on a quarterly basis until final closure of
the facility; and
5)Â Â Â Â Â Â Â Â The owner or operator must comply with the recordkeeping and
reporting requirements in Section 725.194(b).
e)Â Â Â Â Â Â Â Â The groundwater monitoring requirements of this Subpart F may
be waived with respect to any surface impoundment of which the following is
true:
1)Â Â Â Â Â Â Â Â The impoundment is used to neutralize wastes that are
hazardous solely because they exhibit the corrosivity characteristic pursuant
to 35 Ill. Adm. Code 721.122 or which are listed as hazardous wastes in Subpart
D of 35 Ill. Adm. Code 721 only for this reason; and
2)Â Â Â Â Â Â Â Â The impoundment contains no other hazardous wastes, if the
owner or operator can demonstrate that there is no potential for migration of hazardous
wastes from the impoundment. The demonstration must establish, based upon
consideration of the characteristics of the wastes and the impoundment, that
the corrosive wastes will be neutralized to the extent that they no longer meet
the corrosivity characteristic before they can migrate out of the impoundment.
The demonstration must be in writing and must be certified by a qualified
professional.
f)Â Â Â Â Â Â Â Â A permit or enforceable document can contain alternative
requirements for groundwater monitoring that replace all or part of the
requirements of this Subpart F applicable to a regulated unit (as defined in 35
Ill. Adm. Code 724.190), as provided pursuant to 35 Ill. Adm. Code 703.161,
where the Board has determined by an adjusted standard granted pursuant to
Section 28.1 of the Act and Subpart D of 35 Ill. Adm. Code 104 the following:
1)Â Â Â Â Â Â Â Â The regulated unit is situated among solid waste management
units (or areas of concern), a release has occurred, and both the regulated
unit and one or more solid waste management units (or areas of concern) are
likely to have contributed to the release; and
2)Â Â Â Â Â Â Â Â It is not necessary to apply the groundwater monitoring
requirements of this Subpart F because the alternative requirements will adequately
protect human health and the environment. The alternative standards for the
regulated unit must meet the requirements of 35 Ill. Adm. Code 724.201(a).