35 Ill. Adm. Code 725.191
Groundwater Monitoring System
Section 725
Section 725.191Â Groundwater
Monitoring System
a)Â Â Â Â Â Â Â Â A groundwater monitoring system must be capable of yielding
groundwater samples for analysis and must consist of the following components:
1)Â Â Â Â Â Â Â Â Monitoring wells (at least one) installed hydraulically
upgradient (i.e., in the direction of increasing static head) from the limit of
the waste management area. Their number, locations, and depths must be
sufficient to yield groundwater samples that fulfill both of the following
requirements:
A)Â Â Â Â Â Â Â The samples are representative of background groundwater
quality in the uppermost aquifer near the facility; and
B)Â Â Â Â Â Â Â The samples are not affected by the facility; and
2)Â Â Â Â Â Â Â Â Monitoring wells (at least three) installed hydraulically
downgradient (i.e., in the direction of decreasing static head) at the limit of
the waste management area. Their number, locations, and depths must ensure
that they immediately detect any statistically significant amounts of hazardous
waste or hazardous waste constituents that migrate from the waste management
area to the uppermost aquifer.
b)Â Â Â Â Â Â Â Â Separate monitoring systems for each waste management
component of a facility are not required provided that provisions for sampling
upgradient and downgradient water quality will detect any discharge from the
waste management area.
1)Â Â Â Â Â Â Â Â In the case of a facility consisting of only one surface
impoundment, landfill, or land treatment area, the waste management area is
described by the waste boundary (perimeter).
2)Â Â Â Â Â Â Â Â In the case of a facility consisting of more than one surface
impoundment, landfill, or land treatment area, the waste management area is
described by the imaginary boundary line that circumscribes the several waste
management components.
3)Â Â Â Â Â Â Â Â The facility owner or operator may demonstrate that an
alternate hydraulically downgradient monitoring well location will meet the
criteria outlined below. The demonstration must be in writing and kept at the
facility. The demonstration must be certified by a qualified groundwater scientist
and establish each of the following:
A)Â Â Â Â Â Â Â That an existing physical obstacle prevents monitoring well
installation at the hydraulically downgradient limit of the waste management
area.
B)Â Â Â Â Â Â Â That the selected alternate downgradient location is as close
to the limit of the waste management area as practical.
C)Â Â Â Â Â Â Â That the alternate location ensures detection as early as
possible of any statistically significant amounts of hazardous waste or
hazardous waste constituents that migrate from the waste management area to the
uppermost aquifer.
D)Â Â Â Â Â Â Â Lateral expansion, new, or replacement units are not eligible
for an alternate downgradient location under this subsection (b)(3).
c)Â Â Â Â Â Â Â Â All monitoring wells must be cased in a manner that maintains
the integrity of the monitoring well bore hole. This casing must be screened
or perforated and packed with gravel or sand where necessary to enable sample
collection at depths where appropriate aquifer flow zones exist. The annular
space (i.e., the space between the bore hole and well casing) above the
sampling depth must be sealed with a suitable material (e.g., cement grout or
bentonite slurry) to prevent contamination of samples and the groundwater.