35 Ill. Adm. Code 725.192
Sampling and Analysis
Section 725
Section 725.192Â Sampling and
Analysis
a)Â Â Â Â Â Â Â Â The owner or operator must obtain and analyze samples from the
installed groundwater monitoring system. The owner or operator must develop
and follow a groundwater sampling and analysis plan. The owner or operator must
keep this plan at the facility. The plan must include procedures and
techniques for each of the following:
1)Â Â Â Â Â Â Â Â Sample collection;
2)Â Â Â Â Â Â Â Â Sample preservation and shipment;
3)Â Â Â Â Â Â Â Â Analytical procedures; and
4)Â Â Â Â Â Â Â Â Chain of custody control.
BOARD NOTE:Â
See "Procedures Manual For Ground Water Monitoring At Solid Waste Disposal
Facilities", USEPA document number EPA-530/SW-611, and "Methods for
Chemical Analysis of Water and Wastes", USEPA document number EPA-600/4-79-020,
incorporated by reference in 35 Ill. Adm. Code 720.111(a), for discussions of
sampling and analysis procedures.
b)Â Â Â Â Â Â Â Â The owner or operator must determine the concentration or
value of the following parameters in groundwater samples in accordance with
subsections (c) and (d):
1)Â Â Â Â Â Â Â Â Parameters characterizing the suitability of the groundwater
as a drinking water supply, as specified in Appendix C.
2)Â Â Â Â Â Â Â Â The following parameters establishing groundwater quality:
A)Â Â Â Â Â Â Â Chloride,
B)Â Â Â Â Â Â Â Iron,
C)Â Â Â Â Â Â Â Manganese,
D)Â Â Â Â Â Â Â Phenols,
E)Â Â Â Â Â Â Â Sodium, and
F)Â Â Â Â Â Â Â Â Sulfate.
BOARD NOTE:Â
These parameters are to be used as a basis for comparison in the event a
groundwater quality assessment is required under Section 725.193(d).
3)Â Â Â Â Â Â Â Â The following parameters used as indicators of groundwater
contamination:
A)Â Â Â Â Â Â Â pH,
B)Â Â Â Â Â Â Â Specific Conductance,
C)Â Â Â Â Â Â Â Total Organic Carbon, and
D)Â Â Â Â Â Â Â Total Organic Halogen.
c)Â Â Â Â Â Â Â Â Establishing Background Concentrations
1)Â Â Â Â Â Â Â Â For all monitoring wells, the owner or operator must establish
initial background concentrations or values of all parameters specified in
subsection (b). The owner or operator must do this quarterly for one year.
2)Â Â Â Â Â Â Â Â For each of the indicator parameters specified in subsection
(b)(3), the owner or operator must obtain at least four replicate measurements
for each sample and determine the initial background arithmetic mean and
variance by pooling the replicate measurements for the respective parameter
concentrations or values in samples obtained from upgradient wells during the
first year.
d)Â Â Â Â Â Â Â Â After the first year, the owner or operator must sample all
monitoring wells and analyze the samples with the following frequencies:
1)Â Â Â Â Â Â Â Â Samples collected to establish groundwater quality must be
obtained and analyzed for the parameters specified in subsection (b)(2) at
least annually.
2)Â Â Â Â Â Â Â Â Samples collected to indicate groundwater contamination must
be obtained and analyzed for the parameters specified in subsection (b)(3) at
least semi-annually.
e)Â Â Â Â Â Â Â Â The owner or operator must determine the elevation of the
groundwater surface at each monitoring well each time a sample is obtained.