35 Ill. Adm. Code 725.981
Definitions
Section 725.981Â Definitions
As used in this Subpart CC, all
terms not defined in this Section will have the meanings given to them in
section 1004 of RCRA, incorporated by reference in 35 Ill. Adm. Code 720.111, and
35 Ill. Adm. Code 720 through 728.
"Average
volatile organic concentration" or "average VO concentration"
means the mass-weighted average volatile organic concentration of a hazardous
waste, as determined in accordance with the requirements of Section 725.984.
"Closure
device" means a cap, hatch, lid, plug, seal, valve, or other type of
fitting that blocks an opening in a cover so that when the device is secured in
the closed position it prevents or reduces air pollutant emissions to the
atmosphere. Closure devices include devices that are detachable from the cover
(e.g., a sampling port cap), manually operated (e.g., a hinged access lid or
hatch), or automatically operated (e.g., a spring-loaded pressure relief
valve).
"Continuous
seal" means a seal that forms a continuous closure that completely covers
the space between the edge of the floating roof and the wall of a tank. A
continuous seal may be a vapor-mounted seal, liquid-mounted seal, or metallic
shoe seal. A continuous seal may be constructed of fastened segments so as to
form a continuous seal.
"Cover"
means a device that provides a continuous barrier over the hazardous waste
managed in a unit to prevent or reduce air emissions to the atmosphere. A
cover may have openings (such as access hatches, sampling ports, and gauge
wells) that are necessary for operation, inspection, maintenance, or repair of
the unit on which the cover is used. A cover may be a separate piece of
equipment that can be detached and removed from the unit or a cover may be
formed by structural features permanently integrated into the design of the
unit.
"Enclosure"
means a structure that surrounds a tank or container, captures organic vapors
emitted from the tank or container, and vents the captured vapors through a
closed-vent system to a control device.
"External
floating roof" means a pontoon-type or double-deck type cover that rests
on the surface of a hazardous waste being managed in a tank with no fixed roof.
"Fixed
roof" means a cover that is mounted on a unit in a stationary position and
does not move with fluctuations in the level of the material managed in the
unit.
"Floating
membrane cover" means a cover consisting of a synthetic flexible membrane
material that rests upon and is supported by the hazardous waste being managed
in a surface impoundment.
"Floating
roof" means a cover consisting of a double-deck, pontoon single-deck, or
internal floating cover that rests upon and is supported by the material being
contained, and is equipped with a continuous seal.
"Hard-piping"
means pipe or tubing that is manufactured and properly installed in accordance
with relevant standards and good engineering practices.
"In light
material service" means that the container is used to manage a material
for which both of the following conditions apply:Â the vapor pressure of one or
more of the organic constituents in the material is greater than 0.3
kilopascals (kPa) at 20 °C (1.2 inches H
2
O at 68 °F); and the total
concentration of the pure organic constituents having a vapor pressure greater
than 0.3 kPa at 20 °C (1.2 inches H
2
O at 68 °F) is equal to or
greater than 20 percent by weight.
"Internal
floating roof" means a cover that rests or floats on the material surface
(but not necessarily in complete contact with it) inside a tank that has a
fixed roof.
"Liquid-mounted
seal" means a foam or liquid-filled primary seal mounted in contact with
the hazardous waste between the tank wall and the floating roof, continuously
around the circumference of the tank.
"Malfunction"
means any sudden, infrequent, and not reasonably preventable failure of air
pollution control equipment, process equipment, or a process to operate in a
normal or usual manner. A failure that is caused in part by poor maintenance
or careless operation is not a malfunction.
"Maximum
organic vapor pressure" means the sum of the individual organic
constituent partial pressures exerted by the material contained in a tank at
the maximum vapor pressure-causing conditions (i.e., temperature, agitation, pH
effects of combining wastes, etc.) reasonably expected to occur in the tank.
For the purpose of this Subpart CC, maximum organic vapor pressure is
determined using the procedures specified in Section 725.984(c).
"Metallic
shoe seal" means a continuous seal that is constructed of metal sheets
that are held vertically against the wall of the tank by springs, weighted
levers, or other mechanisms and that is connected to the floating roof by
braces or other means. A flexible coated fabric (envelope) spans the annular
space between the metal sheet and the floating roof.
"No
detectable organic emissions" means no escape of organics to the
atmosphere, as determined using the procedure specified in Section 725.984(d).
"Point of
waste origination" means as follows:
When the
facility owner or operator is the generator of the hazardous waste, the
"point of waste origination" means the point where a solid waste
produced by a system, process, or waste management unit is determined to be a
hazardous waste, as defined in 35 Ill. Adm. Code 721.
BOARD NOTE: In
this case, this term is being used in a manner similar to the use of the term
"point of generation" in air standards established for waste
management operations under authority of the federal Clean Air Act in 40 CFR 60
(Standards of Performance for New Stationary Sources), 61 (National Emission
Standards for Hazardous Air Pollutants), and 63 (National Emission Standards
for Hazardous Air Pollutants for Source Categories).
When the
facility owner and operator are not the generator of the hazardous waste,
"point of waste origination" means the point where the owner or
operator accepts delivery or takes possession of the hazardous waste.
"Point of
waste treatment" means the point where a hazardous waste to be treated in
accordance with Section 725.983(c)(2) exits the treatment process. Any waste
determination must be made before the waste is conveyed, handled, or otherwise
managed in a manner that allows the waste to volatilize to the atmosphere.
"Safety
device" means a closure device, such as a pressure relief valve, frangible
disc, fusible plug, or any other type of device that functions exclusively to
prevent physical damage or permanent deformation to a unit or its air emission
control equipment by venting gases or vapors directly to the atmosphere during
unsafe conditions resulting from an unplanned, accidental, or emergency event.Â
For the purpose of this Subpart CC, a safety device is not used for routine
venting of gases or vapors from the vapor headspace underneath a cover such as
during filling of the unit or to adjust the pressure in this vapor headspace in
response to normal daily diurnal ambient temperature fluctuations. A safety
device is designed to remain in a closed position during normal operations and
open only when the internal pressure, or another relevant parameter, exceeds
the device threshold setting applicable to the air emission control equipment
as determined by the owner or operator based on manufacturer recommendations,
applicable regulations, fire protection and prevention codes, standard
engineering codes and practices, or other requirements for the safe handling of
flammable, ignitable, explosive, reactive, or hazardous materials.
"Single-seal
system" means a floating roof having one continuous seal. This seal may be
vapor-mounted, liquid-mounted, or a metallic shoe seal.
"Vapor-mounted
seal" means a continuous seal that is mounted so that there is a vapor
space between the hazardous waste in the unit and the bottom of the seal.
"Volatile
organic concentration" or "VO concentration" means the fraction
by weight of organic compounds contained in a hazardous waste expressed in
terms of parts per million (ppmw), as determined by direct measurement or by
knowledge of the waste, in accordance with the requirements of Section
725.984. For the purpose of determining the VO concentration of a hazardous
waste, organic compounds with a Henry's law constant value of at least 0.1
mole-fraction-in-the-gas-phase/mole- fraction-in-the-liquid-phase (0.1 Y/X)
(which can also be expressed as 1.8x10
-6
atmospheres/gram-mole/m
3
)
at 25 °C (77 °F) must be included. Appendix F presents a list of compounds
known to have a Henry's law constant value less than the cutoff level.
"Waste
determination" means performing all applicable procedures in accordance
with the requirements of Section 725.984 to determine whether a hazardous waste
meets standards specified in this Subpart CC. Examples of a waste determination
include performing the procedures in accordance with the requirements of
Section 725.984 to determine the average VO concentration of a hazardous waste
at the point of waste origination, determining the average VO concentration of
a hazardous waste at the point of waste treatment and comparing the results to
the exit concentration limit specified for the process used to treat the
hazardous waste, the organic reduction efficiency and the organic
biodegradation efficiency for a biological process used to treat a hazardous
waste and comparing the results to the applicable standards, or determining the
maximum volatile organic vapor pressure for a hazardous waste in a tank and
comparing the results to the applicable standards.
"Waste
stabilization process" means any physical or chemical process used to
either reduce the mobility of hazardous constituents in a hazardous waste or
eliminate free liquids as determined by Test Method 9095B (Paint Filter Liquids
Test) in "Test Methods for Evaluating Solid Waste, Physical/Chemical
Methods", USEPA publication number EPA-530/SW-846, incorporated by
reference in 35 Ill. Adm. Code 720.111(a). A waste stabilization process
includes mixing the hazardous waste with binders or other materials and curing
the resulting hazardous waste and binder mixture. Other synonymous terms used
to refer to this process are "waste fixation" or "waste
solidification". This does not include the addition of absorbent materials
to the surface of a waste to absorb free liquid without mixing, agitation, or
subsequent curing.