35 Ill. Adm. Code 726.204
Standards to Control Organic Emissions
Section 726
Section 726.204 Standards to
Control Organic Emissions
a)
Destruction Removal
Efficiency (
DRE) Standard
1) General. Except
for
subsection (a)(3), a
boiler and industrial
furnace (
BIF) burning hazardous waste must achieve a DRE of 99.99
percent for all organic hazardous constituents in the waste feed. To
demonstrate conformance with this requirement, 99.99 percent DRE must be
demonstrated during a trial burn for each principal organic hazardous
constituent (POHC) designated (under subsection (a)(2)) in its permit for each
waste feed. DRE is determined for each POHC from the following equation:
Where:
I
=
Mass feed rate of one POHC in
the hazardous waste fired to the BIF
O
=
Mass emission rate of the same
POHC present in stack gas prior to release to the atmosphere
2) Designation of POHCs. POHCs are those compounds for which
compliance with the DRE requirements of this Section must be demonstrated in a
trial burn in
compliance
with
procedures prescribed in 35 Ill. Adm. Code 703.232. One or more POHCs must be
designated by the Agency for each waste feed to be burned. POHCs must be
designated based on the degree of difficulty of destruction of the organic
constituents in the waste and on their concentrations or mass in the waste feed
considering the results of waste analyses submitted with Part B of the permit
application. POHCs are most likely to be selected from among those compounds
listed in Appendix H to 35 Ill. Adm. Code 721 that are also present in the
normal waste feed. However, if the applicant demonstrates to the Agency that a
compound not listed in Appendix H of 35 Ill. Adm. Code 721 or not present in
the normal waste feed is a suitable indicator of compliance with the DRE
requirements of this Section, that compound must be designated as a POHC. Such
POHCs need not be toxic or organic compounds.
3) Dioxin-Listed Waste. A BIF burning hazardous waste containing
(or derived from) USEPA Hazardous Wastes Nos. F020, F021, F022, F023, F026, or
F027 must achieve a DRE of 99.9999 percent for each POHC designated (under
subsection (a)(2)) in its permit. This performance must be demonstrated on
POHCs that are more difficult to burn than tetra-, penta-, and
hexachlorodibenzo-p-dioxins and dibenzofurans. DRE is determined for each POHC
from the equation in subsection (a)(1). In addition, the owner or operator of
the BIF must notify the Agency of intent to burn USEPA hazardous waste numbers F020,
F021, F022, F023, F026, or F027.
4) Automatic Waiver of DRE Trial Burn. Owners and operators of
boilers operated under the special operating requirements provided by Section
726.210 are considered to be in compliance with the DRE standard of subsection
(a)(1) and are exempt from the DRE trial burn.
5) Low risk waste. Owners and operators of BIFs that burn
hazardous waste in compliance with the requirements of Section 726.209(a) are
considered to be in compliance with the DRE standard of subsection (a)(1) and
are exempt from the DRE trial burn.
b) CO Standard
1) Except
for
subsection (c), the stack gas concentration of CO from a BIF burning hazardous
waste cannot exceed 100 ppmv on an hourly rolling average basis (i.e., over any
60 minute period), continuously corrected to seven percent oxygen, dry gas
basis.
2) CO and oxygen must be continuously monitored
according to
"Performance
Specifications for Continuous Emission Monitoring of Carbon Monoxide and Oxygen
for Incinerators, Boilers, and Industrial Furnaces Burning Hazardous
Waste" in Appendix I.
3) Compliance with the 100 ppmv CO limit must be demonstrated
during the trial burn (for new facilities or an interim status facility
applying for a permit) or the compliance test (for interim status facilities).
To demonstrate compliance, the highest hourly rolling average CO level during
any valid run of the trial burn or compliance test must not exceed 100 ppmv.
c) Alternative CO Standard
1) The stack gas concentration of CO from a BIF burning hazardous
waste may exceed the 100 ppmv limit
if
stack gas concentrations of HCs do not exceed 20 ppmv, except
for
subsection (f) for certain industrial
furnaces.
2) HC limits must be established under this Section on an hourly
rolling average basis (i.e., over any 60 minute period), reported as propane,
and continuously corrected to seven percent oxygen, dry gas basis.
3) HC must be continuously monitored
according to
"Performance Specifications for Continuous
Emission Monitoring of Hydrocarbons for Incinerators, Boilers, and Industrial
Furnaces Burning Hazardous Waste" in Appendix I. CO and oxygen must be
continuously monitored
according to
subsection (b)(2).
4) The alternative CO standard is established based on CO data
during the trial burn (for a new facility) and the compliance test (for an
interim status facility). The alternative CO standard is the average over all
valid runs of the highest hourly average CO level for each run. The CO limit
is implemented on an hourly rolling average basis, and continuously corrected
to seven percent oxygen, dry gas basis.
d) Special Requirements for Furnaces. Owners and operators of
industrial furnaces (e.g., kilns, cupolas) that feed hazardous waste for a
purpose other than solely as an ingredient (see Section 726.203(a)(5)(B)) at
any location other than the end where products are normally discharged and
where fuels are normally fired must comply with the HC limits
of
subsection (c) or (f) irrespective of
whether stack gas CO concentrations meet the 100 ppmv limit of subsection (b).
e) Controls for Dioxins and Furans. Owners and operators of BIFs
that are equipped with a dry PM control device that operates within the temperature
range of 450 °F through 750 °F, and industrial furnaces operating under an
alternative HC limit established under subsection (f) must conduct a site-specific
risk assessment as follows to demonstrate that emissions of chlorinated
dibenzo-p-dioxins and dibenzofurans do not result in an increased lifetime
cancer risk to the hypothetical maximum exposed individual (MEI) exceeding 1 x 10
-5
(1 in 100,000):
1) During the trial burn (for new facilities or an interim status
facility applying for a permit) or compliance test (for interim status
facilities), determine emission rates of the tetra-octa congeners of
chlorinated dibenzo-p-dioxins and dibenzofurans (CDDs/CDFs) using Method 0023A(Sampling
Method for Polychlorinated Dibenzo-p-Dioxins and Polychlorinated Dibenzofurans
Emissions from Stationary Sources) in "Test Methods for Evaluating Solid
Waste, Physical/Chemical Methods," USEPA publication number EPA-530/SW-846,
or Method 23 (Determination of Polychlorinated Dibenzo-
p
-Dioxins and
Polychlorinated Dibenzofurans from Stationary Sources), incorporated by
reference in 35 Ill. Adm. Code 720.111(b);
2) Estimate the 2,3,7,8-TCDD toxicity equivalence of the
tetra-octa CDDs/CDFs congeners using section 4.0 (Procedures for Estimating the
Toxicity Equivalence of Chlorinated Dibenzo-p-Dioxin and Dibenzofuran Congeners)
in appendix IX to 40 CFR 266 (Methods Manual for Compliance with the BIF
Regulations), incorporated by reference in 35 Ill. Adm. Code 720.111(b) (see Appendix
I). Multiply the emission rates of CDD/CDF congeners with a toxicity
equivalence greater than zero (see the procedure) by the calculated toxicity
equivalence factor to estimate the equivalent emission rate of 2,3,7,8-TCDD;
3) Conduct dispersion modeling using methods recommended in appendix
W to 40 CFR 51 (Guideline on Air Quality Models), in section 5.0 (Hazardous
Waste Combustion Air Quality Screening Procedure) in appendix IX to 40 CFR 266
(Methods Manual for Compliance with the BIF Regulations), or in "Screening
Procedures for Estimating Air Quality Impact of Stationary Sources, Revised,"
USEPA publication number EPA-454/R-92-019, each incorporated by reference in 35
Ill. Adm. Code 720.111, to predict the maximum annual average off-site ground
level concentration of 2,3,7,8-TCDD equivalents determined under subsection
(e)(2). The maximum annual average on-site concentration must be used when a
person resides on-site; and
4) The ratio of the predicted maximum annual average ground level
concentration of 2,3,7,8-TCDD equivalents to the risk-specific dose (RSD) for
2,3,7,8-TCDD provided in Appendix E (2.2 x 10
-7
) must not exceed
1.0.
f) Monitoring CO and HC in the By-Pass Duct of a Cement Kiln.
Cement kilns may comply with the CO and HC limits provided by subsections (b),
(c), and (d) by monitoring in the by-pass duct
if
the following conditions are met:
1) Hazardous waste is fired only into the kiln and not at any
location downstream from the kiln exit relative to the direction of gas flow;
and
2) The by-pass duct diverts a minimum of 10 percent of kiln
off-gas into the duct.
g) Use of Emissions Test Data to Demonstrate Compliance and Establish
Operating Limits. Compliance with the requirements of this Section must be
demonstrated simultaneously by emissions testing or during separate runs under
identical operating conditions. Further, data to demonstrate compliance with
the CO and HC limits of this Section or to establish alternative CO or HC
limits under this Section must be obtained during the time that DRE testing,
and where applicable, CDD/CDF testing under subsection (e) and comprehensive
organic emissions testing under subsection (f) is conducted.
h) Enforcement. For the purposes of permit enforcement,
compliance with the operating requirements specified in the permit (under
Section 726.202) will be regarded as compliance with this Section. However,
evidence that compliance with those permit conditions is insufficient to ensure
compliance with the requirements of this Section is "information"
justifying modification or revocation and re-issuance of a permit under 35 Ill.
Adm. Code 703.270 et seq.