35 Ill. Adm. Code 726.205
Standards to Control PM
Section 726
Section 726.205 Standards to
Control PM
a) A BIF burning hazardous waste must not emit PM in excess of
180 mg/dry standard m
3
(0.08 grains/dry standard cubic foot) after
correction to a stack gas concentration of seven percent oxygen, using
procedures prescribed in the following methods in appendix A to 40 CFR 60 (Test
Methods), each incorporated by reference in 35 Ill. Adm. Code 720.111(b) (see Appendix
I)
: Method 1
(Sample and Velocity
Traverses for Stationary Sources)
, Method 2
(Determination of Volatile Organic Compound Leaks)
, Method 2A
(Direct Measurement of Gas Volume through Pipes and
Small Ducts)
, Method 2B
(Determination of Exhaust Gas Volume Flow Rate from Gasoline Vapor
Incinerators)
, Method 2C
(Determination of Gas Velocity and Volumetric Flow Rate in Small Stacks or
Ducts (Standard Pitot Tube))
, Method 2D
(Measurement of Gas Volume Flow Rates in Small Pipes and Ducts)
, Method 2E
(Determination of Landfill Gas
Production Flow Rate)
, Method 2F
(Determination of Stack Gas Velocity and Volumetric Flow Rate with
Three-Dimensional Probes)
, Method 2G
(Determination of Stack Gas Velocity and Volumetric Flow Rate with Two-Dimensional
Probes)
, Method 2H
(Determination of
Stack Gas Velocity Taking into Account Velocity Decay Near the Stack Wall)
, Method 3
(Gas Analysis for the
Determination of Dry Molecular Weight)
,
Method 3A
(Determination of Oxygen and Carbon Dioxide Concentrations in
Emissions from Stationary Sources (Instrumental Analyzer Procedure))
, Method 3B
(Gas Analysis for the
Determination of Emission Rate Correction Factor or Excess Air)
, Method 3C
(Determination of Carbon
Dioxide, Methane, Nitrogen, and Oxygen from Stationary Sources)
, Method 4
(Determination of Moisture
Content in Stack Gases)
, Method
5
(Determination of Particulate Matter Emissions from Stationary Sources),
Method
5A (Determination of Particulate
Matter Emissions from the Asphalt Processing and Asphalt Roofing Industry),
Method
5B (Determination of Nonsulfuric
Acid Particulate Matter Emissions from Stationary Sources),
Method
5D (Determination of Particulate
Matter Emissions from Positive Pressure Fabric Filters),
Method
5E (Determination of Particulate
Matter Emissions from the Wool Fiberglass Insulation Manufacturing Industry),
Method
5F (Determination of Nonsulfate
Particulate Matter Emissions from Stationary Sources),
Method
5G (Determination of Particulate Matter Emissions from
Wood Heaters (Dilution Tunnel Sampling Location)),
Method
5H (Determination of Particulate Emissions from Wood
Heaters from a Stack Location),
and Method
5I
(Determination of Low Level Particulate Matter Emissions from Stationary
Sources).
b) An owner or operator meeting the requirements of Section
726.209(b) for the low risk waste exemption is exempt from the PM standard.
c) Oxygen Correction
1) Measured pollutant levels must be corrected for the amount of
oxygen in the stack gas according to the following formula:
Where:
P
c
=
the corrected concentration of the pollutant in the stack
gas
P
m
=
the measured concentration of the pollutant in the stack
gas
E
=
the oxygen concentration on a dry basis in the combustion
air fed to the device
Y
=
the measured oxygen concentration on a dry basis in the
stack
2) For devices that feed normal combustion air, E will equal 21
percent. For devices that feed oxygen-enriched air for combustion (that is, air
with an oxygen concentration exceeding 21 percent), the value of E will be the
concentration of oxygen in the enriched air.
3) Compliance with all emission standards provided by this Subpart
H must be based on correcting to seven percent oxygen using this procedure.
d) For the purposes of permit enforcement, compliance with the
operating requirements specified in the permit (under Section 726.202) will be
regarded as compliance with this Section. However, evidence that compliance
with those permit conditions is insufficient to ensure compliance with the
requirements of this Section is "information" justifying modification
or revocation and re-issuance of a permit under 35 Ill. Adm. Code 703.270
through 703.273.