35 Ill. Adm. Code 816.530
Testing of Poz-O-Tec Liners and Caps and Poz-O-Tec Monofills
Section 816
Section 816.530Â Testing of
Poz-O-Tec Liners and Caps and Poz-O-Tec Monofills
The owner or operator shall
implement the following material testing procedures for testing Poz-O-Tec
liners and caps and Poz-O-Tec Monofills:
a)Â Â Â Â Â Â Â Â Creation and Sampling of Test Pad
1)Â Â Â Â Â Â Â Â The owner or operator shall construct a test pad in accordance
with 35 Ill. Adm. Code 811.507(a), unless such construction is waived by the
Agency pursuant to subsection (b) of that Section;
2)        The test pad shall be allowed to cure for 56 days at 73°
Fahrenheit (or equivalent cure);
3)Â Â Â Â Â Â Â Â After curing, fifty samples shall be taken using a 4 inch
diameter coring bit; and
4)Â Â Â Â Â Â Â Â The specimens shall be trimmed to proctor cylinder size
utilizing an abrasive blade masonry saw and tested for unconfined compressive
strength and coefficient of permeability as described in subsection C below.Â
Of the specimens taken from the pad, 20 shall be analyzed for their coefficient
of permeability and 30 shall be analyzed for their unconfined compressive
strength.
b)Â Â Â Â Â Â Â Â Collection of Production Samples
The owner or
operator shall collect samples from the production of Poz-O-Tec in the
following manner:
1)Â Â Â Â Â Â Â Â Utilizing a large scoop, five gallon buckets of freshly
produced material shall be collected at uniform intervals during construction
of the test pad and shipped to a laboratory for analysis.
2)Â Â Â Â Â Â Â Â Five proctor cylinder specimens shall be prepared from each
bucket of freshly produced material. Three of these five cylinders shall be
tested for unconfined compressive strength and the other two shall be tested
for permeability.
3)Â Â Â Â Â Â Â Â Additional uncured samples shall be taken as necessary for
preparation and testing to determine moisture content, lime content, the ratio
of fly ash to sludge and in-place density. Testing for these parameters shall
be conducted in accordance with standard test methods.
c)Â Â Â Â Â Â Â Â Strength and Permeability Testing
1)Â Â Â Â Â Â Â Â Uncured samples shall be taken to a laboratory, placed into
proctor cylinders, compacted to simulate field conditions, cured in sealed
containers for 56 days at 73° (or equivalent cure) and tested for coefficient
of permeability and unconfined strength using the following test methods, which
are incorporated by reference in 35 Ill. Adm. Code 810.104:
A)Â Â Â Â Â Â Â U.S. Army Corps of Engineers Engineering Manual 1110-2-1906
Appendix VII, Falling-Heal Permeability Test with Permeameter Cylinder.
B)Â Â Â Â Â Â Â ASTM Method D5102; Standard Method for Unconfined Compressive
Strength of Cohesive Soils.
2)Â Â Â Â Â Â Â Â Field samples shall be tested using the same methods as
specified in subsection (c)(1) above.
d)Â Â Â Â Â Â Â Â Data Correlation
Laboratory
data and field data shall be compared to determine any statistically
significant differences using standard statistical correlation methodologies.
e)Â Â Â Â Â Â Â Â Subsequent Testing
Upon
completion of field verification, as described above in (c)(2), the owner or
operator of the site shall conduct quality control/quality assurance testing by
taking monthly samples of freshly produced Poz-O-Tec materials and sending
those samples to a laboratory where they shall be formed into proctor cylinder
specimens for testing. Two of those samples shall be tested for their
coefficient of permeability, three for unconfined compressive strength, and one
each for the parameters set forth in subsection (b)(3) above. Laboratory
testing for permeability and strength must be conducted in accordance with the
test methods referenced in subsection (c). Test results must demonstrate a
coefficient of permeability of less than or equal to 1 x 10
-7
cm/sec
using a geometric average of the permeability testing results and an unconfined
compressive strength of greater than or equal to 150 psi using an arithmetic
average of the strength testing results.