35 Ill. Adm. Code 845.460
Safety Factor Assessment
Section
845.460 Safety Factor
Assessment
a) The
owner or operator of a CCR surface impoundment must conduct an initial and
annual
safety factor assessment
for each CCR surface
impoundment and document whether the calculated factors of safety for each CCR
surface impoundment achieve the minimum safety factors specified in this
Section for the critical cross-section of the embankment. The critical cross-section
is the cross‑section anticipated to be the most susceptible of all cross-sections
to structural failure based on appropriate engineering considerations,
including loading conditions. The safety factor assessments must be supported
by appropriate engineering calculations.
1) For
new CCR surface impoundments, the calculated static factor of safety under the
end-of-construction loading condition must equal or exceed 1.30. The
assessment of this loading condition is only required for the initial safety
factor assessment and is not required for subsequent assessments.
2) The
calculated static factor of safety under the long-term, maximum storage pool
loading condition must equal or exceed 1.50.
3) The
calculated static factor of safety under the maximum surcharge pool loading
condition must equal or exceed 1.40.
4) The
calculated seismic factor of safety must equal or exceed 1.00.
5) For
dikes constructed of soils that have susceptibility to liquefaction, the
calculated liquefaction factor of safety must equal or exceed 1.20.
b)
The owner or operator of the CCR surface impoundment must
obtain a certification from a qualified professional engineer stating that the
initial safety factor assessment and each annual assessment thereafter was
conducted in accordance with the requirements of this Section.
c) Timeframe
for Submission of the
Safety Factor Assessment
1) The
owner or operator of a new CCR surface impoundment must submit the initial
safety factor assessment certification with the initial operating permit
application before the initial receipt of CCR in the surface impoundment.
2) The
owner or operator of an existing CCR surface impoundment must submit the
initial safety factor assessment certification with its first annual inspection
report required by Section 845.540(b).
3) The
owner or operator of a CCR surface impoundment must submit the annual safety
factor assessment certification each year with the annual inspection required
by Section 845.540(b).
4) The
owner or operator of a new CCR surface impoundment must place each safety
factor assessment in the facility's operating record as required by Section
845.800(d)(6).
d) Failure to Document
Minimum Safety Factors
1) For
new CCR surface impoundments, until the date an owner or operator of a CCR
surface impoundment documents that the calculated factors of safety achieve the
minimum safety factors specified in this Section, the owner or operator is
prohibited from placing CCR in the CCR surface impoundment.
2) An
owner or operator of the CCR surface impoundment who either fails to complete a
timely safety factor assessment or fails to demonstrate minimum safety factors
as required by this Section is subject to the requirements of Section 845.700.
e) The requirements
of this Section apply to all CCR surface impoundments, except for those CCR
surface impoundments that are incised CCR surface impoundments. If an incised
CCR surface impoundment is subsequently modified (e.g., a dike is constructed)
such that the CCR surface impoundment no longer meets the definition of an
incised CCR surface impoundment, the CCR surface impoundment is subject to the
requirements of this Section.