56 Ill. Adm. Code 6000.351
Haunted Houses
Section 6000.351 Haunted Houses
a) Emergency Planning
1) Maximum
occupant load, which shall include staff, shall be determined during plan
review. A sign stating maximum occupant capacity shall be posted in a visible
location near the entrance, and staff shall control the flow of patrons so as
not to exceed this limit.
2) A
written emergency procedure plan shall be provided with the permit application
packet. All employees shall be trained in emergency procedure.
3) The
emergency procedure plan shall include training of staff and familiarization
with fire alarm tone. Specific personnel shall be designated to turn off all
distracting noises (e.g., sound system) and turn on lights when alerted by the
fire alarm or otherwise notified of an emergency condition.
4) While
the haunted house is open to the public, it shall be adequately staffed to
control the occupant load and assist patrons in exiting should an evacuation
become necessary. Staffing level shall be determined upon review of plans and
may be increased at the discretion of the fire department.
5) All
employees shall carry flashlights and know the location of all exits, fire
extinguishers, light switches, electrical panels and emergency phones.
6) A
fire drill demonstrating the implementation of the emergency plan may be
required at the time of inspection.
7) Phone
communication shall be readily available for the purpose of calling 911 in the
event of an emergency.
b) Exits
1) Two
exits shall be provided from each room with an occupant load of 50 or more.
Required exit doors shall swing in the direction of egress.
2) Naturally
or artificially illuminated exit signs shall be provided at each exit.
3) Exit
doors serving an occupant load of 50 or more shall not be provided with a latch
or lock other than panic hardware.
4) Emergency
lighting shall be provided.
5) Exhibits
and decorative materials shall not obstruct, confuse or obscure exits, exit
pathways, exit signs or emergency lighting units.
6) Additional
pathway markings, including low level marking and signs, may be required during
the field inspection.
c) Fire Protection
1) Fire
and smoke detecting systems shall be installed in each building or structure
used in an amusement ride or amusement attraction that requires a darkened
interior during operation.
2) Fire
extinguishers shall be:
A) Minimum
2A10BC rated.
B) Visible
and accessible at all times and clearly illuminated or marked with reflective
tape.
C) Located
within 50 feet travel distance from anywhere in the building.
3) Decorative
materials shall not obstruct fire sprinklers, fire extinguishers or any other
fire protection equipment.
4) Fabric
constituting part of an amusement ride or amusement attraction shall meet the
flamespread ratings of NFPA 701. A certificate or a test report from the fabric
manufacturer or approved testing agency indicating a fire resistance rating
equal to or better than NFPA 701 shall be available upon request.
5) "No
Smoking" signs shall be posted at the entrances/exits to all amusement
rides or amusement attractions that require a darkened interior during
operation.
d) Electrical
1) Extension
cords shall be of heavy commercial type, UL listed and in good condition, and
shall be appropriate for the intended use.
2) Only
UL listed power strips with over-current protection shall be used when the
number of outlets provided is inadequate. Power strips shall be plugged
directly into provided outlets and shall not be plugged into one another in
series.
3) All
extension cords and power strips shall be adequately protected from foot
traffic ("bridged") if paths of travel cannot be avoided.
4) Emergency
Lighting. If an amusement attraction requires a darkened interior during
operation, each building or structure shall be equipped with a battery powered
emergency lighting system.
e) Decorative Materials
1) All
decorative materials (decorations, drapes, backdrops and props) shall be either
inherently flame retardant and labeled as such, or shall be treated with a
flame retardant.
2) If
material is treated by the user, a container and receipt will serve as proof. A
flame test may be required.
3) Care
and consideration shall be used with respect to smoke generator and smoke alarm
locations. Use of smoke generators may be restricted if determined to be
incompatible with the smoke alarms.
f) Miscellaneous
1) Storage
or use of flammable or combustible liquids, gasses and solids is prohibited.
2) Open
flame is prohibited.
3) Good
housekeeping shall be maintained throughout exhibit and exit pathways at all
times.
4) There
shall be no sharp corners, splintered wood walls or protruding screws or nails
that can cause injury.
5) Carnival
or amusement workers working at haunted houses are not permitted to have
physical contact with patrons unless such physical contact is in the course of
rendering aid, to remove a patron from the attraction, or in the interest of
avoiding injury to employees, volunteers, or patrons as provided for in Section
2-19 of the Act.