a)Â Â Â Â Â Â Â Â Equipment and Utensils
1)Â Â Â Â Â Â Â Â The equipment, sanitary piping and utensils used in receiving
and processing of the milk, and manufacturing and handling of the product shall
be maintained in a sanitary condition. Sanitary seal assemblies shall be
removable on all agitators, pumps and vats, and shall be inspected at regular
intervals and kept clean. Unless other provisions are recommended in the
following supplemental sections, all equipment not designed for C.I.P. cleaning
shall be disassembled after each day's use for thorough cleaning. Dairy
cleaners, detergents, wetting agents, sanitizing agents or other similar
materials which will not contaminate or adversely affect the products may be
used. Steel wool or metal sponges shall not be used in the cleaning of any
dairy equipment or utensils. All product contact surfaces shall be subjected
to an effective sanitizing treatment immediately prior to use, except where dry
cleaning is permitted in accordance with Subpart E. Utensils and portable
equipment used in processing and manufacturing operations shall be stored above
the floor in clean, dry locations and in a self draining position on racks
constructed of impervious corrosion-resistant material.
2)Â Â Â Â Â Â Â Â C.I.P. cleaning, including sprayball systems, shall be used
only on equipment and pipeline systems which have been designed and engineered
for that purpose. When such cleaning is used, careful attention shall be given
to the proper procedures to assure satisfactory cleaning. All C.I.P.
installations and cleaning procedures shall be in accordance with 3-A Suggested
Methods for the Installation and Cleaning of Cleaned-In-Place Sanitary Milk
Pipelines for Milk and Milk Products Plants. The established cleaning
procedure shall be posted and followed. Following the circulation of the cleaning
solution the equipment and lines shall be thoroughly rinsed with lukewarm water
and checked for effectiveness of cleaning. All caps, plugs, special fittings,
valve seats, cross ends, pumps, plates, and the ends shall be opened or removed
and brushed clean. Immediately prior to starting the product flow, the product
contact surfaces shall be given bactericidal treatment.
b)Â Â Â Â Â Â Â Â Milk Tank Trucks:Â A covered or enclosed wash dock and
cleaning and sanitizing facilities shall be available to all plants that receive
or ship milk in milk tank trucks. Milk tank trucks, sanitary piping, fittings,
and pumps shall be cleaned and sanitized at least once each day, after use:Â Provided,
that if they are not to be used immediately after emptying a load of milk, they
shall be washed promptly after use and given bactericidal treatment immediately
before use. After being washed and sanitized, each milk tank truck shall be
identified by a tag attached to the outlet valve, bearing the following
information:Â Plant and specific location where cleaned, date and time of day
of washing and sanitizing, and name of person who washed and name of person who
sanitized the milk tank truck. The tag shall not be removed until the milk
tank truck is again washed and sanitized.
c)Â Â Â Â Â Â Â Â Building:Â All windows, glass, partitions, and skylights shall
be washed as often as necessary to keep them free from dust and debris. The
material picked up by the vacuum cleaners shall be disposed of by burning or
other proper methods to destroy any insects that might be present.