77 Ill. Adm. Code 820.220
Swimming Facility Bather Preparation Facilities
Section 820
Section 820.220Â Swimming Facility
Bather Preparation Facilities
a)        General Requirements. Bather preparation facilities shall be
provided in accordance with subsections (b), (c) and (d) of this Section except
where the facility is intended to serve living units (such as hotels, motels,
apartments, condominiums, dormitories, subdivisions, and resident institutions)
where each living unit contains at least one toilet and one shower and is
within 500 feet of the facility entrance.
b)Â Â Â Â Â Â Â Â Design Requirements
1)Â Â Â Â Â Â Â Â Bather preparation facilities to be used by both sexes shall
be divided into separate areas designated for each sex.
2)Â Â Â Â Â Â Â Â Floors of bather preparation facilities, including showers,
restrooms, dressing and locker rooms, and connecting walkways, shall be
slip-resistant, impervious to moisture, and sloped to drain at least 1 inch in
10 feet. Material used for floor covering in these areas shall comply with
Section 820.200(j)(4). Alternative floor coverings may be installed in locker
or dressing areas with prior approval of the Department, if the Department
determines that the installation is unlikely to result in a condition
detrimental to public health. In considering approval of an installation of an
alternative product, the Department shall consider:
A)Â Â Â Â Â Â Â Whether the product is likely to become or to remain wet,
considering separation distance between locations where the floor covering
product would be installed and wet areas, such as toilet and shower facilities,
and anticipated usage of the facility;
B)Â Â Â Â Â Â Â Properties of the product, including factors affecting rate of
drying, propensity of the product to support microbial growth, and ease of
cleaning and disinfecting;
C)Â Â Â Â Â Â Â If the Department learns that a condition detrimental to public
health results from the installation of an alternative product, or if there is
failure to comply with the care and maintenance conditions specified with the
approval, whether to order removal of the alternative product.
3)Â Â Â Â Â Â Â Â Bather preparation facilities serving swimming facilities with
bather loads of greater than 200 shall be designed so that passage from the
showers to the swimming facility shall not be through dressing room areas and
other dry areas of the bather preparation facility.
4)Â Â Â Â Â Â Â Â The rooms shall be ventilated and lighted.
5)Â Â Â Â Â Â Â Â A hose bibb shall be provided in each side of the bather
preparation facilities.
c)        Showers, Toilets, and Lavatories. Showers and lavatories
shall be provided with liquid or powdered soap dispensers. Showers shall be
supplied with water at a temperature of at least 90° F and not more than 115° F
with temperature controls that prevent scalding. The number of fixtures
provided shall be as shown in Appendix B.Table E. At a swimming facility used
by school classes, one shower for every four persons in the largest class shall
be provided for each sex, except that in no case shall the number be less than
shown in Appendix B.Table E.
d)        Dressing Rooms. For swimming facilities with a bather load of
more than 300, a dressing area shall be provided for each sex. Shower and
toilet areas and walkways shall not be considered dressing areas.
e)        Foot Spray. A foot spray, if provided, shall be supplied from
the potable water system or the swimming facility recirculation system, have a
spray head 18 to 24 inches above the walkway, have a conveniently located
valve, be arranged to spray the bathers from knees to feet as they enter the
enclosure, and have a drain.
f)        Foot Bath. No new footbaths may be constructed or installed
after May 20, 1999.